Catalog excerpts
Giving neonates a future Comprehensive respiratory support solutions medfri A Hamilton Medical ComDanv
Open the catalog to page 1Our heart beats for premature infants and newborns Our full commitment and knowledge are focused on lung-protective solutions for respiratory support in order to ease the workload of hospital staff in the best way possible. With our innovations, we contribute to the survival of the smallest patients and support the gentlest possible start to life. Premature infants and newborns need a familiar environment. Like the nursing staff, we also consider ourselves to be a part of this family. We work carefully, are solution-oriented, and respond to individual needs. In doing so, our focus is always...
Open the catalog to page 2Everything you need As the only manufacturer, we offer solutions and products for the complete spectrum of from one source non-invasive respiratory support for premature infants and newborns. You get a large, comprehensive and coordinated toolkit for the NIV therapy of your small patients, from CPAP to assisted respiratory support to non-invasive HFO. Our accessories are perfectly coordinated to medin devices. They can also be used with many other devices and thus provide you with varied and, above all, practical solutions. Giving neonates a future Comp re He ibm i^vufary supfHrt sdutnns...
Open the catalog to page 3medinSINDI® nCPAP and high-flow With the nCPAP and high-flow modes, medinSINDI offers a reliable and economical solution for basic NIV therapy of small patients. In combination with the Medijet generator, medinSINDI measures CPAP pressure and respiratory rate. In addition, alarm functions such as the upper and lower pressure limit and a disconnection alarm offer additional security. Through the integrated oxygen/compressed air blender, medinSINDI enables precise adjustment of the flow and the oxygen concentration. HFNC-mode and nCPAP in one device Spontaneous respiratory rate display 5...
Open the catalog to page 4medinCNO®mini nCPAP and high-flow medinCNOmini offers the basic nCPAP and high-flow functions of a modern CPAP device. In addition, the device has a special ApneaCPAP mode. With the aid of the MediTRIG respiratory trigger, the spontaneous breathing is detected near the patient and without any additional sensors. MediTRIG can be individually adapted to the patient’s spontaneous breathing. In the event of apnea, the patient’s inspiration is stimulated through automatically activated mechanical breaths. All basic modes for NIV respiratory support HFNC-mode and nCPAP in one device Apnea...
Open the catalog to page 5medinCNO® nCPAP device with nHFV medinCNO is a versatile nCPAP device which is used to provide respiratory support to premature infants and newborns. In combination with Medijet®, the compact device is a stand-alone system and meets all requirements for non-invasive nCPAP therapy. With five modes (CPAP, ApneaCPAP, NIPPV, SNIPPV, Oscillation), medinCNO offers comprehensive non-invasive support in neonatology and is the only nCPAP device with nHFV. nCPAP with nHFV Synchronized NIPPV Apnea monitoring MediTRIG: Integrated trigger without additional sensor Leakage compensation
Open the catalog to page 6The new generation of non-invasive respiratory support medin-NC3 is the first turbine-driven CPAP device for non-invasive respiratory support for premature infants and newborns. The high-performance turbine makes the device independent of a fixed compressed air supply. The proven MediTRIG technology is used in the ApneaCPAP mode. Powerful leakage compensation offsets leakages to ensure stable and effective therapy. Independent from air supply thanks to high-performance turbine All basic modes for non-invasive respiratory support HFNC-mode and nCPAP in one device Leak compensation in all...
Open the catalog to page 7Versatile The air/oxygen blenders from medin can be used for a variety of applications: Oxygen therapy, EasyCPAP therapy with the Medijet generator, BubbleCPAP with Miniflow interface or Pediflow NIV mask as well as nHFT therapy with medin high-flow cannula medinBlender 1090 The medinBlender 1090 is a mechanical gas blender with two integrated flow meters (0-15 L/min and 0-3.5 L/min) for nCPAP, BubbleCPAP therapy and high-flow applications in neonatology and pediatrics as well as conventional oxygen therapy in adults. V High degree of accuracy at low flow rates V Continuous oxygen...
Open the catalog to page 8BubbleCPAP Easy application In the case of the BubbleCPAP, positive pressure is applied to the airways during inspiration and expiration. Pressure is generated through the expired breathing gas being directed into a water container (bubbler). A dip tube (surge chamber) is on the end of the expiratory ventilation tube. The level of the CPAP pressure depends on how deep the end of the cylinder is immersed into the sterile water. This simple CPAP system was used for the first time in the early 1970s (Gregory 1971) and it has been used worldwide since then. In 1987, it was demonstrated (Avery...
Open the catalog to page 9Miniflow® Miniflow is our interface for CPAP/NIV therapy using conventional ventilators. The interface is Passive nCPAP interface y branches of the tubing system with the ventilator or flow source. Combining Miniflow with ventilators enables CPAP therapy and non-invasive ventilation modes such as NIPPV. In this way, the therapy parameters are controlled as usual via the ventilator. As needed, pressure measurement near the patient can be connected to the Miniflow. The single-use interface allows all forms and modes of modern NIV therapy for premature infants and newborns. Compatible with...
Open the catalog to page 10Medijet® – Active nCPAP interface Medijet is our active nCPAP generator and is used on the medin devices medin-NC3, medinCNO, medinCNOmini and medinSINDI. In addition, the interface can also be combined with several special ventilators. Medijet is quieter than comparable nCPAP generators (Kirchner 2012) and features a high level of comfort. Medijet actively generates CPAP pressure using a modified Benveniste valve (Benveniste 1976), that is, directly in the generator, and thus the continuous positive pressure in the patient’s airway without an additional valve in the NIV device. As a...
Open the catalog to page 11All Medin Medical Innovations GmbH catalogs and technical brochures
-
Nuflow®
2 Pages
-
Pb_1000_long
3 Pages
-
PB_medinBLENDER_1093_1094
2 Pages
-
OP_heated_circuits_all_languages
24 Pages
-
OP_Nuflow_all_languages
127 Pages
-
OP_Medijet
103 Pages
-
Pb_4000_long
3 Pages
-
OP_Miniflow
103 Pages
-
OP Bubble
2 Pages
-
Processing
4 Pages
-
Pb_20674X_short
2 Pages
-
Pb_20674X_long
3 Pages
-
Pb_1207_long
2 Pages
-
PB_1207MKI
2 Pages
-
PB_1207
2 Pages
-
OP_Blender_Rev09_all languages
115 Pages
-
Nuflow® Nasal cannula set
2 Pages
-
Promo Sheet Nuflow
2 Pages
-
Order Information Nuflow
2 Pages
-
OP_medinCNO_3090_REV12
68 Pages
-
OP Pediflow all languages
65 Pages
-
OP_medinCNOmini_3080_EN_Rev03
64 Pages
-
OP_medinSINDI_1080_REV14
36 Pages
-
Guideline_for_Transport_Rev06
20 Pages
Archived catalogs
-
medin Company Brochure
16 Pages
-
Flyer_medin_Rev04
2 Pages
-
Prospect_products_medin_Rev09
20 Pages
-
medinCNO®mini
4 Pages
-
MEDINsindi
2 Pages
-
Short_Application_Medijet_
2 Pages
-
Catalogue Pediflow®
4 Pages
-
Prospect_nasal_canula
4 Pages
-
Prospect_Miniflow_Bubble
4 Pages
-
Prospect_medinCNO
4 Pages
-
Medin_Catalog
16 Pages
-
Flyer_reuseable_bonnets
1 Pages
-
user_manual_medinSINDI
36 Pages
-
OP_Blender
18 Pages
-
OP_Circuits_heated
32 Pages
-
user_manual_medinCNO
59 Pages
-
OP_Miniflow_4000
96 Pages
-
OP_Medijet_1010_1020
4 Pages
-
OP_Medijet_1000
104 Pages
-
OP_Circuits_unheated
32 Pages
-
technical_data_medinSINDI
1 Pages
-
products_medin
16 Pages