sindi Universal gas delivery unit with multi function monitor REF 1080 Technical specifications Pneumatic: • Universal driver with pneumatic gas blender for oxygen and air • Setting range 21% to 100% oxygen – step less • Automatic alarm system for drop in air or oxygen pressure • Independent from electrical power • Pressure of oxygen and air supply: 3,5 to 6 bar. • Pressure difference of air and oxygen supply < 1 bar • Integrated flow meter with needle valve, range 0 to 16 L / min. • Flow outlet connector, universal standard with adaptors for 15 and 22 mm • Integrated oxygen sensor for FiO2 measurement • Type of oxygen sensor: OOM102 and MLF 16 • Mechanical Blender independent from electronic and monitor functions Electronic: • The electronic system is completely battery driven and recharged by an ext. power supply • Operating time in battery-powered mode is approx. 5 hours (for transportation) • Internal battery: 9,6 Volt NiCd recharge, easy to exchange • Continuous running with ext. power supply • Measurment data output by RS 232 Monitor with 96 x 61 mm embedded LCD display: • Solution 240 x 128 dots B/W • Background illumination (automatically reduced in battery powered mode) • Microprocessor controlled data scanning system with EEPROM (update possibility) Display and Functions: • ON and OFF button for the device on the front • Report of nCPAP pressure: analogue curve and digital form • Report of oxygen concentration: bar-graph and digital form • Report of spontaneous breathing frequency: blinking and digital form • Report of flexible setting of upper and lower alarm for nCPAP pressure • Reset of alarms - mute for 2 minutes or quit • Activation of FiO2 concetration alarm (±10%) • Disconnection alarm for nCPAP circuits Purpose of use: Therapeutic enrichment of the respiratory gas mixture with oxygen for neonates and premature babies. Used in combination with the nCPAP Medijet® Generator for supportive respiration with a constant positive arwaiy pressure (CPAP). Mounting: • Easy mounting of driver on standard hospital rail (10x25 mm) with integrated clamps • Pole mounting with rail clamp converter, very easy to handle (no tools needed) Important instructions: The device may only be used with simultaneous hemodynamic monitoring of the patient. The gas blender may only be used by trained medical personnel. FOR CLINICAL USE ONLY Certification in accordance with DIN EN ISO 9001, DIN EN ISO 13485, Annex II section 3 of the Council Directive 93/42EEC

Open the catalog to page 1

All Medin Medical Innovations GmbH catalogs and technical brochures

  1. Nuflow®

    2 Pages

  2. Pb_1000_long

    3 Pages

  3. OP_Medijet

    103 Pages

  4. Pb_4000_long

    3 Pages

  5. OP_Miniflow

    103 Pages

  6. OP Bubble

    2 Pages

  7. Processing

    4 Pages

  8. Pb_1207_long

    2 Pages

  9. PB_1207MKI

    2 Pages

  10. PB_1207

    2 Pages

Archived catalogs

  1. MEDINsindi

    2 Pages

  2. Medin_Catalog

    16 Pages

  3. OP_Blender

    18 Pages

  4. OP_Medijet_1000

    104 Pages

  5. products_medin

    16 Pages