Overview: The Meditech MD8000 is a 12.1-inch color TFT patient monitor capable of displaying 7 channels of ECG in one frame. It includes standard parameters such as ECG, NIBP, RESP, digital SPO2, TEMP, and PR, with optional configurations for IBP, ECTO2, a recorder (printer), drug dose calculation, and OXYCRG. The device supports up to 72 hours of data storage and offers networking capabilities.
Display and Interface: The monitor features a high-brightness 12.1-inch TFT display, allowing simultaneous display of 7-lead ECG. It provides real-time ST segment and arrhythmia analysis, with powerful data review options for graphic and tabular trends, as well as alarm reviews. The interface supports big fonts, oxyCRG, and a full-lead ECG display to meet various requirements. It can connect to a central monitoring system via LAN or wireless network.
ECG Specifications: The ECG system supports leads I, II, III, aVR, aVL, aVF, and V, with gain settings of 5mm/mV, 10mm/mV, 20mm/mV, 40mm/mV, and auto. It has an input impedance of ≥5MΩ and a common mode rejection ratio of ≥100dB. The bandwidth varies by mode: 0.5–25Hz (monitoring), 0.05–75Hz (diagnostic), and 1–15Hz (surgical). It offers protection against high-frequency electrotome and defibrillation effects, with a scanning speed of 25mm/s or 50mm/s and a heart rate range of 0-300 BPM with ±1 BPM accuracy.
NIBP Specifications: The NIBP uses oscillometry with manual, automatic, and STAT operation modes. It measures systolic, diastolic, and mean pressures in mmHg or KPa, with a range of 10-270 mmHg for adults. It includes over-pressure protection and a resolution of 1 mmHg, adhering to ANSI/AAMI SP-10 standards for accuracy.
SpO2 Specifications: The SpO2 measurement range is 0-100%, with an accuracy of ±2 digits for 70-100% and unspecified for 0-69%. The alarm range is 0-100%.
Respiration and Temperature: Respiration is measured using oscillometry, with manual, automatic, and STAT modes. Temperature measurement is dual-channel with a resolution of 0.1°C and an alarm range of 0-50°C.
Optional Features: The monitor can be configured with additional options such as EtCO2, IBP, and a recorder.
See more

Catalog excerpts

MD8000-1

MD8000 patient monitor Meditech MD8000 is a 12.1" color TFT patient monitor, can display 7 channels ECG by one frame. It has standard parameters of ECG, NIBP, RESP, digital SPO2, TEMP and PR with optional configuration IBP, ECTO2, recorder (printer), drug dose calculation and OXYCRG. It has maximum 72 hours storage capacity and a networking ability. 12.1 inch high brightness colorful TFT Display Simultaneous display of 7 lead ECG by one frame A nalysis of real time ST segment and arrhythmia Powerful data review for graphic, tabular trends and alarms review Standard parameter of ECG, NIBP, RESP, digital SPO2, TEMP and PR with optional configuration IBP, ECTO2 and recorder (printer), drug dose calculation and OXYCRG Maxi 72 hour graphic and tabular trend with data storage Big font, oxyCRG, Full-lead ECG interface to meet different requirement; LAN or wireless network connection as central monitoring system; Digital SPO2 enables effective examination in case of active patient, low infusion and interference from electric knife Protection against high-frequency electrotome and defibrillation effects ECG: lead: ¢ñ¢ò¢ó,aVR ,aVL ,aVF ,V Gains: 5mm/mV;10mm/mV;20mm/mV;40mm/mV;auto Input i mpedance : ¡Ý5M Common Mode Rejection Ratin: ¡Ý100dB Bandwidth: 0.5¡ª25Hz(monitoring mode) 0.05-75Hz(diagnostic mode) 1¡ª15Hz (surgical mode) Protection: segregation breakdown Vo ltage 4000VAC,50/60Hz,Resistant to high-frequency etectro tome myoelectricity ,AC,drifting interference Indication of Detachment of electrodes:Available in isolation against electrosurgical interference and defibrillation Playback of cardiogram: Available Scanning speed: 25mm/s;50mm/s Heart Rate Range: 0-300BPM Accuracy: ¡À1BPM NIBP: Method: Oscillometry Oper ation modes: Manual/Automatic/STAT Measurement unit: mmHg/KPa selectable Measurement types: Systolic, Diastolic, Mean Measurement range: Adult: 10-270mmHg Over-pressure protection: YES Resolution: 1mmHg Accuracy: Mean error and standard deviation per ANSI/AAMI SP-10 Alarm: Systolic, Diastolic, Mean SpO2: Measurement range: 0-100% Ac curacy: ¡À2digit (70~100%);0~69% unspecified Alarm range: 0-100% Respiration: Method: Osci llometry Operation modes: Manual/Automatic/STAT Measurement unit: mmHg/KPa selectable Measurement types: Systolic, Diastolic, Mean Measurement range: Adult: 10-270mmHg T emperature: Resolution: 0.1¡æ Channel: Dual-channel Alarm range: 0-50¡æ Options: EtCO2 , IBP , Recorde r

 Open the catalog to page 1

All Meditech Equipment catalogs and technical brochures

  1. Oxima2 Vet

    3  Pages

  2. Sonovet ID

    1  Page

  3. BabySono

    2  Pages

  4. SonoTech Pro

    3  Pages

  5. SonoTech Lite

    2  Pages

  6. Sonotech M2

    3  Pages

  7. Sono R

    2  Pages

  8. iSono

    2  Pages

  9. Oxy plus

    2  Pages

  10. iBreathe CP

    1  Page

  11. Defi6

    2  Pages

  12. FOs2

    2  Pages

  13. Spiro P

    1  Page

  14. FOs3+

    2  Pages

  15. POxi2

    1  Page

  16. SpirOx Lite

    1  Page

  17. SpirOx

    3  Pages

  18. Convex Probe

    1  Page

  19. MD3100

    2  Pages

  20. MD3203D

    3  Pages

  21. MD8015

    2  Pages

  22. MD 06x

    3  Pages

  23. MD-Touch

    2  Pages

  24. MD 9015

    1  Page

  25. Echo80

    2  Pages

  26. MDP100

    1  Page

  27. ibeat

    2  Pages

  28. EKG-6012

    4  Pages

  29. EKG 1212T

    2  Pages

  30. MDP85

    1  Page

  31. MDP90

    2  Pages

  32. MDP80w

    1  Page

  33. Cardios pro

    1  Page

  34. ECG-101T

    2  Pages

  35. Defi

    2  Pages

*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.