Solar DC Compressor
3Pages

{{requestButtons}}

Catalog excerpts

Solar DC Compressor - 1

Evaporating Temp -23.3°C Suction Temp 32.2°C Condensing Temp 54.4°C Sub cooling Temp 32.2°C Ambient Temp 32.2°C testing voltage 12VDC controller This compressor motor runs on DC brushless motor. When you use this controller , You must be properly connect with compressor. Connection as below: ©12/24VDC power supply © fuse © power switch ©fault indicator lamp ©12V radiating fan© thermostat switch ©speed regulation resistor@power protection resistor Head Office: No.6 President Terrace. Takli Road, Dwarka. Nashik-422011 Phone:0253 - 6418632 Email: info@newmeditech.com. Website: www.newmeditech.com

Open the catalog to page 1
Solar DC Compressor - 2

2. (12VDC) 7.5A (24VDC) For protection of installation ,fuse© must be connected with positive wire and close to power supply .15A fuse for 12VDC, 7.5A fuse for 24VDC are recommended. 3. If a main switch © is used, the rated current shall be min 20A. 4. In order to avoid excessive voltage change caused by the controller to protect,don’t add other circuit in the circuit. 5. A 10mA light emitting diode® can be connected between the terminals + and D.The number of flashed depends on what kind of operational error was recorded.Each flash will last 1/5second.If the launch failure each interval 60...

Open the catalog to page 2
Solar DC Compressor - 3

battery voltage protection setting. The relation of battery voltage protection resistor setting and power protection resistor® is as below: Controller automatically adjusts to the applied voltage.If power voltage is less than 17V,the controller will work in 12VDC system. If power voltage is more than 17V,the controller will work in 24VDC system.If a 220KQ resistor is connected between C and P, compressor work voltage range will be extended to 9.6V~31.5V.

Open the catalog to page 3

All Meditech Technologies India catalogs and technical brochures

  1. walk in cooler

    11 Pages

  2. cold room

    10 Pages

  3. co2 incubator

    15 Pages

  4. BOD Incubator

    10 Pages

  5. Incubator

    2 Pages

  6. MTCR 60

    6 Pages

  7. MTPS432

    5 Pages

  8. MTPS360

    5 Pages

  9. MTPS288

    5 Pages

  10. MTPS216

    5 Pages

  11. MTPS144

    5 Pages

  12. MTPS72

    5 Pages

  13. MBDW80

    11 Pages

  14. MBDW120

    11 Pages

  15. MBDW40

    11 Pages

  16. Camping Cot

    1 Pages

  17. MTR30

    3 Pages

  18. MTR26

    3 Pages

  19. ME7-2

    3 Pages

  20. ME8

    8 Pages

  21. MTBDR16

    3 Pages

  22. MTAC60

    7 Pages

  23. MTAC40

    7 Pages

  24. MTAC26

    3 Pages

  25. MA1000

    3 Pages

  26. Spirometer

    1 Pages

  27. Cold rooms

    10 Pages

Archived catalogs