Overview: Meditech offers environmentally friendly cold rooms designed for blood banks, featuring advanced technology for temperature control, space utilization, and operational efficiency. These cold rooms are equipped with intelligent systems to ensure reliability and product stability.
Specifications:
  • Temperature uniformity of ±0.5ºC and a maximum temperature gradient of 1.0ºC.
  • Custom-cut wall panels for optimal space utilization.
  • Noise level maintained at a maximum of 70dBA.
  • Digital temperature controls with a touch screen interface.
  • Intelligent alarms for active monitoring and corrective actions.
  • Surface finishes include baked white enamel powder-coated mild steel and SS panels for corrosive environments.
Operational Features:
  • Recessed fluorescent lighting for optimal illumination.
  • Center-mount, low-velocity air handler for uniform air distribution.
  • Precision temperature and humidity sensors for accurate monitoring.
  • Resistive heaters and ultrasonic transducers for precise temperature and humidity control.
Reliability and Safety:
  • Extra equipment capacity for handling unusual cooling and heating loads.
  • Automatic compressor restarts for continuous operation.
  • Active alarms with SMS features for immediate alerts.
Software and Monitoring:
  • 21 CFR part 11 USFDA compliant software with validation documents.
  • Web-based remote monitoring and control via SAIF53 software.
  • Centralized alarms and notifications through SMS and email.
  • Real-time and historical data logging with automatic backup.
Technical Data:
  • Models available with temperature range of 2°C to 4°C and accuracy of ±0.2°C.
  • Various sizes available, with custom dimensions on request.
Interface and User Experience:
  • Touch screen interface for easy navigation and control.
  • Real-time and historical trend analysis for temperature monitoring.
  • USB data transfer for temperature logs.
  • Optional SMS alerts for critical parameters.
See more

Catalog excerpts

Cold rooms for Blood Bank-1

Cold Rooms For Blood Bank Environmentally friendly Cold Rooms powered by Meditech Technology Head Office: No.6 President Terrace. Takli Road, Dwarka. Nashik-422011 Phone:0253 - 6418632 Email: [email protected]. Website: www.newmeditech.com

 Open the catalog to page 1
Cold rooms for Blood Bank-2

Cold Rooms For Blood Bank Environmentally friendly Cold Rooms powered by Meditech Technology Standard features of cold rooms include: Temperature uniformity ±0.5ºC • Temperature gradient of 1.0ºC Max. • No-waste, custom-cut wall panels • Average 70dBA maximum noise level • Digital temperature controls with Touch Screen • Narrow-range chart recorder, accurate to ±0.5% of the –100 to 100ºC spare on demand • Intelligent, active high/low alarms • CFC Free insulated panels with SS304 inside and Galvanneled Mild steel with powder coated Outside (or) SS304 inside and outside Complete utilization of...

 Open the catalog to page 2
Cold rooms for Blood Bank-3

Cold Rooms For Blood Bank Humidity control Reliable, trouble-free operation Meditech cold rooms are equipped with extra equipment capacity for unusual peaks in cooling and heating loads. Also, all Meditech refrigeration systems have safety features such as automatic compressor restarts. Such robust design-features help ensure continuous reliability of Meditech mechanical systems. SPECIFYING COLD ROOMS Cold rooms can be designed to maintain virtually any temperature required for life science and food storage applications. To ensure the room meets your particular requirements, consider these issues...

 Open the catalog to page 3
Cold rooms for Blood Bank-4

Cold Rooms For Blood Bank Environmentally friendly Cold Rooms powered by Meditech Technology Software • 21 CFR part 11 USFDA compliant software with validation documents. • Secured audit Trail. • Multi level security password with aging and history. • Electronic signature. • Web based (Ethernet) online remote monitoring • GSM alarm system (mobile alert) • Data of door access security system in software with remote options. • All the events, utility, working status, all the alarms are logged in the software. • Records in graphical and in tabular form. • Reports of mean Kinetic Temperature Reading....

 Open the catalog to page 4
Cold rooms for Blood Bank-5

Environmentally friendly Cold Rooms powered by Meditech Technology Centralized user defined Alarms,alerts and Notifications through SMS & emails Configure the type & no.of alarms to be sent via email/SMS & configure delay time too Running time calculation of MKT and Moving Average Component running hours to determine the shelf-life of major components Real-time display of all connected equipment in single screen Automatic data backup facility System Diagnosis for troubleshooting via Team Viewer Ethernet communication with chambers Complying US FDA 21 CFR Part11 For more than a decade, Meditech...

 Open the catalog to page 5
Cold rooms for Blood Bank-6

Technical Data for walk in type cooling cabinet Standard Model(S): Inside S.S.304 with mirror polish & outside mild steel powder coated. GMP Model(G):Inside and outside with SS 304 matt buff. Temp. Range /Accuracy.: 2°C to 4°C /± 0.2°C Temp Uniformity : ± 1°C Note: Other sizes are available on request. Head Office: No.6 President Terrace. Takli Road, Dwarka. Nashik-422011 Phone:0253 - 6418632 Email: [email protected]. Website: www.newmeditech.com

 Open the catalog to page 6
Cold rooms for Blood Bank-7

Cold Rooms for Blood Bank

 Open the catalog to page 7
Cold rooms for Blood Bank-8

Cold Room – Plasma Freezer Room and Blood Storage Room Touch Screen Interface- Menu Items Manual Operations Chart/Trends USER LOGIN

 Open the catalog to page 8
Cold rooms for Blood Bank-9

Cold Room – Plasma Freezer Room and Blood Storage Room Touch Screen Interface- Parameters Display – Home page Total Blood Count Temperature inside the room Individual Blood Count Temperature inside the room

 Open the catalog to page 9
Cold rooms for Blood Bank-10

Cold Room – Plasma Freezer Room and Blood Storage Room Touch Screen Interface- Parameters Display – Parameters These parameters are factory set. These values cannot be changed by the user. These values gives high impact on the performance of the machine.

 Open the catalog to page 10
Cold rooms for Blood Bank-11

Cold Room – Plasma Freezer Room and Blood Storage Room Touch Screen Interface- Parameters Display – MENU ITEMS Calendar Settings

 Open the catalog to page 11
Cold rooms for Blood Bank-12

Cold Room – Plasma Freezer Room and Blood Storage Room Touch Screen Interface- Parameters Display – IO STATUS Clock: USE + and – sign to set the time CALENDAR Clock: USE + and – sign to set the time

 Open the catalog to page 12
Cold rooms for Blood Bank-13

Cold Room – Plasma Freezer Room and Blood Storage Room Touch Screen Interface- SCADA SOFTWARE INVENTORY MANAGEMENT SYSTEM NOTE: The above system works with SCADA system designed by Meditech for Cold room. Works only if SCADA system is purchased by Meditech

 Open the catalog to page 13
Cold rooms for Blood Bank-14

Cold Room – Plasma Freezer Room and Blood Storage Room Touch Screen Interface- SCADA SOFTWARE INVENTORY MANAGEMENT SYSTEM USER NAME AND PASSWORDS: This panel is used to create user name and password In case SCADA system and SMS module is purchased, then all critical parameter SMS will go to above three mobile numbers of logged user.

 Open the catalog to page 14
Cold rooms for Blood Bank-15

Cold Room – Plasma Freezer Room and Blood Storage Room Touch Screen Interface- TRENDS TRENDS TRENDS are real time graphs of TEMPERATURE VS TIME Two Type of TRENDS are REAL TIME and HISTORICAL (1) REAL TIME : All real time data log of 24 hours is displayed of temperature and time (2) HISTORICAL : Any data log of back dated time can be displayed. Start date and END date can be selected to display the trend

 Open the catalog to page 15
Cold rooms for Blood Bank-16

Cold Room – Plasma Freezer Room and Blood Storage Room Touch Screen Interface- USB USB All temperature Log data (TRENDS) can be easily transferred to a PEN drive using above MENU. Select the START date and END Date and select transfer DATA to USB

 Open the catalog to page 16
Cold rooms for Blood Bank-17

Cold Room – Plasma Freezer Room and Blood Storage Room Touch Screen Interface- SMS SMS: This is an optional feature. User logged shall receive SMS for all critical parameters if send SMS feature is kept on.

 Open the catalog to page 17
Cold rooms for Blood Bank-18

Cold Room – Plasma Freezer Room and Blood Storage Room Touch Screen Interface- ALARMS ALARMS: The above screen displays the High temperature and low temperature alarms

 Open the catalog to page 18

All Meditech Technologies India catalogs and technical brochures

  1. walk in cooler

    11  Pages

  2. cold room

    10  Pages

  3. co2 incubator

    15  Pages

  4. BOD Incubator

    10  Pages

  5. Incubator

    2  Pages

  6. MTCR 60

    6  Pages

  7. MTPS432

    5  Pages

  8. MTPS360

    5  Pages

  9. MTPS288

    5  Pages

  10. MTPS216

    5  Pages

  11. MTPS144

    5  Pages

  12. MTPS72

    5  Pages

  13. MBDW80

    11  Pages

  14. MBDW120

    11  Pages

  15. MBDW40

    11  Pages

  16. Camping Cot

    1  Page

  17. MTR30

    3  Pages

  18. MTR26

    3  Pages

  19. ME7-2

    3  Pages

  20. ME8

    8  Pages

  21. MTBDR16

    3  Pages

  22. MTAC60

    7  Pages

  23. MTAC40

    7  Pages

  24. MTAC26

    3  Pages

  25. MA1000

    3  Pages

  26. Spirometer

    1  Page

  27. Walk in freezer

    11  Pages

  28. Cold rooms

    10  Pages

  29. CO2 incubator

    7  Pages

  30. Solar freezer

    7  Pages

*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.