Product Overview and Applications
The MBDW series walk-in chamber is specifically designed for research on C4 high-light plants. It features a modular design with a top-down airflow pattern to ensure consistent temperatures across the plant canopy. The interior walls are made of spectral aluminum to enhance light uniformity, and a separate cooling system is included to manage heat from the lighting system.

Lighting
The standard lighting package includes metal halide and tungsten incandescent lamps, providing a broad light spectrum. Optional lighting packages are available for higher intensities and programmable control.

Airflow
The chamber employs a top-down airflow pattern with independent ventilation and conditioning systems. Pressure transducers monitor the refrigeration system, with alternative methods available for specific needs.

Experiment Protection
User-programmable alarms monitor chamber operations, with backup alarms for added security. Both visual and audible notifications are provided when alarms are activated.

Key Product Attributes
  • High light availability and uniformity
  • Discrete lamp loft to reduce heat transfer
  • Top-down airflow for uniform temperatures
  • Extended height for accommodating large plant growth
  • Modular design for scalability
  • CE certified

Refrigeration
The chamber includes a water-cooled condensing unit with a hot gas bypass for continuous operation. An electronic modulating valve ensures precise temperature control.

Performance Data
The temperature range is -2°C to +40°C with lights off and +5°C to +45°C with lights on. The chamber is available in various sizes, offering different growth areas and capacities.

Control System
A 7” Meditech touch screen controller is used for chamber operation.

Construction
The chamber is constructed with galvanized steel and polyurethane insulation. It features a safety release latch door, observation window, and instrument ports.

Lighting
Lighting intensity is 1,100 micromoles/m²/s, with independent programming for each lamp type. Lamps are separated from the growth area by a transparent barrier.

Temperature Control
The temperature range is +4°C to +40°C with lights off and 10°C to 40°C with lights on. Safety features include programmable alarms and independent factory-set limits.

Cooling System
The system includes a water-cooled condensing unit with an electronic modulating valve and CFC-free refrigerant.

Air Flow
The chamber features vertical airflow from perforated diffusers and a filtered fresh air inlet.

Optional Accessories
  • UPS for uninterrupted power supply
  • High intensity discharge lighting
  • Humidity and CO2 control options
  • Growth height extensions
  • Right-hand control panel
  • Refrigeration options for lamp loft cooling
See more

Catalog excerpts

MBDW40-1

Plant Growth Room MBDW Walk In Room Head Office: No.6 President Terrace. Takli Road, Dwarka. Nashik-422011 Phone:0253 - 6418632 Email: [email protected]. Website: www.newmeditech.com

 Open the catalog to page 1
MBDW40-2

Plant Growth Room MBDW Walk In Room Product Overview/Applications The MBDW series walk-in chamber is based on a modular platform available in increments of 40ft2 (3.7m2). These units offer a precise chamber environment typical of research involving C4 high-light plants grown to maturity. Unique is the top-down airflow pattern which ensures consistent plant canopy temperatures throughout the chamber. Spectral aluminum on the interior walls produces unparalleled light uniformity, while the discreet lamp loft area uses a separate cooling system to mitigate heat produced by the lighting system. control...

 Open the catalog to page 2
MBDW40-3

Plant Growth Room MBDW Walk In Room 7” Meditech touch screen controller MBDW40 2.0 Construction:(Note: All dimensions are nominal.) 2.1 Exterior Dimensions: 10’0”W x 5’10”D x 9’6.25”H (3050mmW x 1780mmD x 2900mmH) 2.2 Interior Dimensions: 7’9”W x 5’2”D x 7’11”H (2360mmW x 1575mmD x 2415mmH) 2.3 Growth Area: 40.0ft² (3.7m²) 2.4 Growth Capacity: 316ft³ (8,920 liters) 2.5 Growth Height: 95” (2415mm) from floor to underside of barrier. 2.6 Exterior Finish: White enamel baked on stucco 26ga. galvanized steel. 2.7 Interior Finish: White enamel baked on smooth 24ga. galvanized steel with specular aluminum...

 Open the catalog to page 3
MBDW40-4

Plant Growth Room MBDW Walk In Room 4.4 Temperature Safety Limits: Primary: A programmable min and max temperature limit alarm or a limit tracking alarm that automatically follows the programmed set point. Secondary: An independent factory-set high and low temperature limit is also provided for increased assurance. An audible alarm is standard for both limits. Activation of temperature safety limit set points turns off power to the chamber. 4.5 All components utilized for temperature control such as heaters and proportional valve are energized and deenergized by solid state devices. No electro-mechanical...

 Open the catalog to page 4
MBDW40-5

Plant Growth Room Walk In Room UPS Uninterrupted Power Supply Surge protection and uninterrupted power supply, on controller only, for continuous operation of the controller during power interruptions, duration of the UPS is approx. 15 minutes. (Consult factory for increased duration, if required.) High Intensity Discharge Lighting High intensity discharge lighting using 400 watt metal halide and 400 watt high pressure sodium lamps with a light intensity of 1100 micromoles/m2/s at a distance of 1 meter from the barrier. Upon start-up, lamps experience a 5 to 10 minute warm up period before full...

 Open the catalog to page 5
MBDW40-6

Growth Height Extension Reduced growth height by 12” (305mm). Exterior height becomes 8’6.25”H (2600mm). Growth Height Extension Extended growth height by an additional 17" (430mm). Exterior height becomes 10’11.25"H (3335mm). Growth Height Extension Extended growth height by an additional 48" (406mm). Exterior height becomes 13’6.25"H (4120mm). Right-Hand Control Panel Right-hand control compartment gives you the convenience and flexibility to arrange your chambers in a compact orderly fashion, back to back and end to end, or to facilitate its location in any appropriate space. Hose Bib Interior...

 Open the catalog to page 6
MBDW40-7

Remote outdoor air-cooled condenser complete with all weather housing, low ambient operation controls and low noise level operation. Remote location (up to 50’ [15m] combined horizontal and vertical distance) of condenser only - compressor, receiver and other refrigeration components remain in cabinet machine compartment. Order “RACH" for climates with ambient temperatures from +35°C to +45°C for extended periods. Electrical: 60Hz - 2O8-23O-10-6OHz-3 wire plus ground, 50Hz - 22O-10-5OHz-2 wire plus ground. Consult factory for either amperages or other voltages available. Notes: 1. Inter-connecting...

 Open the catalog to page 7
MBDW40-8

Plant Growth Room MBDW Walk In Room FOLLOWING ARE THE DIFFERENCES BETWEEN THE “MBDW SERIES” CHAMBERS MBDW80 2.1 Exterior Dimensions: 10’0”W x 11’1.25”D x 9’6.25”H (3050mmW x 3385mmD x 2900mmH) 2.2 Interior Dimensions: 7’9”W x 10’5”D x 7’11”H (2360mmW x 3180mmD x 2410mmH) 2.3 Growth Area: 80.9ft2 (7.5m2) 2.4 Growth Capacity: 640ft³ (18,075 liters) 6.2 Fresh Air: Filtered inlet 100 cfm (48 liters/second). MBDW120 2.1 Exterior Dimensions: Cabinet - 10’0”W x 16’4.5”D x 9’6.25”H (3050mmW x 4991mmD x 2900mmH) 2.2 Interior Dimensions: 7’9”W x 15’8”D x 7’11”H (2360mmW x 4790mmD x 2410mmH) 2.3 Growth...

 Open the catalog to page 8
MBDW40-9

Plant Growth Room MBDW Walk In Room MBDW40 PLANT GROWTH CHAMBER NOTES: 1. STANDARD REFRIGERATION SYSTEM IS WATER COOLED (3/4"Ø (19mmØ) CONNECTION). 2. DEPTH DIMENSION IS CHAMBER SIZE ONLY. DIMENSION DOES NOT INCLUDE DOOR LATCH. 3. LENGTH AND WIDTH DIMENSIONS ±1/4 (6mm). HEIGHT DIMENSION ±1" (25mm). Head Office: No.6 President Terrace. Takli Road, Dwarka. Nashik-422011 Phone:0253 - 6418632 Email: [email protected]. Website: www.newmeditech.co

 Open the catalog to page 9
MBDW40-10

Plant Growth Room MBDW Walk In Room BDW80 PLANT GROWTH CHAMBER NOTES: 1. STANDARD REFRIGERATION SYSTEM IS WATER COOLED (3/4"Ø (19mmØ) CONNECTION). 2. CONDENSING UNIT REQUIRES SEPERATE ELECTRICAL SERVICE (60HZ APPLICATION ONLY). 3. DEPTH DIMENSION IS CHAMBER SIZE ONLY. DIMENSION DOES NOT INCLUDE DOOR LATCH. 4. LENGTH AND WIDTH DIMENSIONS ±1/4 (6mm). HEIGHT DIMENSION ±1" (25mm). Head Office: No.6 President Terrace. Takli Road, Dwarka. Nashik-422011 Phone:0253 - 6418632 Email: [email protected]. Website: www.newmeditech.co

 Open the catalog to page 10
MBDW40-11

1. STANDARD REFRIGERATION SYSTEM IS WATER COOLED (3/4”0 (19mm0) CONNECTION). 2. CONDENSING UNIT REQUIRES SEPERATE ELECTRICAL SERVICE (60HZ APPLICATION ONLY). 3. DEPTH DIMENSION IS CHAMBER SIZE ONLY. DIMENSION DOES NOT INCLUDE DOOR LATCH. 4. LENGTH AND WIDTH DIMENSIONS ±1/4 (6mm). HEIGHT DIMENSION ±1” (25mm). CONDENSING UNIT BARRIERED LAMP LOFT -LAMP LOFT COOLING COIL CONTROL PANEL SECTIONAL LAMP BARRIER (HINGED DOWN FOR LAMP AND BALLAST SERVICING) OBSERVATION WINDOW C/W LIGHT TIGHT COVER DUAL SIDEWALL MOUNTED AIR HANDLER/HEAT EXCHANGER PLENUMS -FRESH AIR (2) MAIN COOLING COIL (6) .INSTRUMENT...

 Open the catalog to page 11

All Meditech Technologies India catalogs and technical brochures

  1. walk in cooler

    11  Pages

  2. cold room

    10  Pages

  3. co2 incubator

    15  Pages

  4. BOD Incubator

    10  Pages

  5. Incubator

    2  Pages

  6. MTCR 60

    6  Pages

  7. MTPS432

    5  Pages

  8. MTPS360

    5  Pages

  9. MTPS288

    5  Pages

  10. MTPS216

    5  Pages

  11. MTPS144

    5  Pages

  12. MTPS72

    5  Pages

  13. MBDW80

    11  Pages

  14. MBDW120

    11  Pages

  15. Camping Cot

    1  Page

  16. MTR30

    3  Pages

  17. MTR26

    3  Pages

  18. ME7-2

    3  Pages

  19. ME8

    8  Pages

  20. MTBDR16

    3  Pages

  21. MTAC60

    7  Pages

  22. MTAC40

    7  Pages

  23. MTAC26

    3  Pages

  24. MA1000

    3  Pages

  25. Spirometer

    1  Page

  26. Walk in freezer

    11  Pages

  27. Cold rooms

    10  Pages

  28. CO2 incubator

    7  Pages

  29. Solar freezer

    7  Pages

*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.