video corpo

CardiUP12_sample_report
4Pages

{{requestButtons}}

Catalog excerpts

CardiUP12_sample_report - 1

Patient name: demo (pacemaker) CardiUP!12 Patient ID: 0001_0001 Date of birth: CardiUP!12 report Start of the examination 2015.02.02. Meditech Kft. Budapest 1184 Mikszath Kalman u. 24. Tel. 36(1)280-82-32 Fax. 36(1)282-93-88 This examination has been made with the CardiUP!12 device, serial number ED1 00000001.The start of measurement 2015.02.02. 11:57, end 2015.02.03. 11:57, complete duration 24:00. The device functions properly. In the examination there was 23:59:44 length of good quality 12 channel ECG recording. The recordings According to the modified evaluation made by the doctor, show 96311 heart cycles, of which 10.96 % normal beats, Ves:0.13% , SVes:0.23% , Pacemaker:88.68% . The normal beats can be classified into 1, Ves beats 2, SVes beats 1 groups. ECG dominant rhythm is pacemaker rhythm. Average heart rate (based on 30 second averages) for 24 hours 66/minute, day 68/minute, night 64/minute, during the morning period 62/minute. Maximum heart rate 90/minute at 14:01, minimum heart rate 59/minute at 03:20. Pause (2.5 sec) not exsist. Supraventricular ectopy: relatively frequent SVES beats and SV tachycardia/paroxism. Ventricular ectopy: relatively frequent VES beats. ST60 average value for 24 hours stI=-0.01 stII=-0.03 stIII=-0.02 staVR=0.01 staVL=0.02 staVF=-0.03 stV1=0.01 stV2=-0.02 stV3=-0.04 stV4=-0.04 stV5=-0.04 stV6=-0.03 . Total ischaemic burden stI=00:00 stII=00:08 stIII=00:02 staVR=00:00 staVL=00:00 staVF=00:04 stV1=00:00 stV2=00:02 stV3=00:02 stV4=00:02 stV5=00:02 stV6=00:00 , number of ischaemic events 7. Longest ischaemic event 3.0 min depression on the II channel at 16:57, deepest -0.22 mV. Deepest ST depression 16:57 at -0.22 mV on the II channel. Pacemaker: number of pacemaker induced beats: 85409 HRV: The average RR distance is 893 ms. 24-hour HRVti: 7, based on this the risk factor is high; SDNN: 87, based on this the risk factor is moderate. Atrial fibrillation not exsist page: 1 total: 4 pages

Open the catalog to page 1
CardiUP12_sample_report - 2

CardiUP!12 report Start of the examination 2015.02.02. Patient name: demo (pacemaker) CardiUP!12 Patient ID: 0001_0001 Date of birth: page: 2 total: 4 pages

Open the catalog to page 2
CardiUP12_sample_report - 3

Patient name: demo (pacemaker) CardiUP!12 Patient ID: 0001_0001 Date of birth: CardiUP!12 report Start of the examination 2015.02.02. page: 3 total: 4 pages

Open the catalog to page 3
CardiUP12_sample_report - 4

Patient name: demo (pacemaker) CardiUP!12 Patient ID: 0001_0001 Date of birth: CardiUP!12 report Start of the examination 2015.02.02. page: 4 total: 4 pages

Open the catalog to page 4

All Meditech catalogs and technical brochures

  1. Demo ApneABP

    4 Pages

  2. ABPM

    3 Pages