cardXplore_sample_report
4Pages

{{requestButtons}}

Catalog excerpts

cardXplore_sample_report - 1

Patient name: Demo 210 card(X)plore Patient ID: 0001-0210 Date of birth: card(X)plore report Start of the examination 2018.01.04. Meditech Kft. Budapest 1184 Mikszath Kalman u. 24. Tel. 36(1)280-82-32 Fax. 36(1)282-93-88 This examination has been made with the card(X)plore device, serial number CT2 00000001.The start of measurement 2018.01.04. 11:01, end 2018.01.05. 10:54, complete duration 23:53. The device functions properly, sometimes the cuff was not on the patient's arm during the measurements.. In the examination there was 23:52:35 length of good quality 3 channel ECG recording, From 40 inflation there were 26 successful blood pressure measurements. . The examination can be divided into day 06:00-22:00, night 22:00-06:00 periods. The 24-hour systolic/diastolic average blood pressure was 153/80 mmHg, daytime average 151/81 based on 21 recordings, night time average 156/74 based on 5 recordings. Average pulse rate for 24 hours 84/minutes, day 86, night 74. The systolic/diastolic diurnal index is -3/8 negative, within non-dipper range. The recordings According to the modified evaluation made by the doctor, show 116696 heart cycles, of which 99.72 % normal beats, Ves:0.27% . The normal beats can be classified into 1, Ves beats 3, SVes beats 1 groups. ECG dominant rhythm is sinus rhythm. Average heart rate (based on 30 second averages) for 24 hours 80/minute, day 84/minute, night 73/minute. Maximum heart rate 120/minute at 10:12, minimum heart rate 55/minute at 01:48. Pause (2.5 sec) exsist 5 times. Supraventricular ectopy: relatively frequent SVES beats and SV tachycardia/paroxism. Ventricular ectopy: relatively frequent VES beats. ST60 average value for 24 hours stA=-0.01 stB=-0.02 stC=-0.01 . Total ischaemic burden stA=00:00 stB=00:00 stC=00:01 , number of ischaemic events 0. HRV: The average RR distance is 735 ms. 24-hour HRVti: 32, based on this the risk factor is low; SDNN: 159, based on this the risk factor is low. Atrial fibrillation: located ( Total length 23:51:54 ) QT maximum: 464 ms ( 01:57 ) QTc maximum: 507 ms ( 01:27 ) page: 1 total: 4 pages

Open the catalog to page 1
cardXplore_sample_report - 2

Patient name: Demo 210 card(X)plore Patient ID: 0001-0210 Date of birth: card(X)plore report Start of the examination 2018.01.04. Blood pressure chart BP [mmHg] 230 created 2018.01.05. page: 2 total: 4 pages

Open the catalog to page 2
cardXplore_sample_report - 3

Patient name: Demo 210 card(X)plore Patient ID: 0001-0210 Date of birth: card(X)plore report Start of the examination 2018.01.04. ECG spikechart Pause 5 [pcs] Missing beat 658 [pcs Atrial fibrillation 1 [pcs] Ves Beats 316 [pcs V couplet 5 [pcs] SVes Beats 15 [pcs] SV tachycardia/part 1 [pcs] R on T 17 [pcs] QTc long (LQTS) 4 [pcs] Tachycardia 708 [pcs Bradycardia 37 [pcs] QTc max 1 [pcs] page: 3 total: 4 pages

Open the catalog to page 3
cardXplore_sample_report - 4

Patient name: Demo 210 card(X)plore Patient ID: 0001-0210 Date of birth: card(X)plore report Start of the examination 2018.01.04. created 2018.01.05. page: 4 total: 4 pages

Open the catalog to page 4