S390L (Firefly WDR) - 2

Simple Design + Simple Operation The design was inspired from the shape of firefly. The smart design largely saves space for clinicians compared other bulky camera systems.We have preset many camera parameters so the user does not need to adjust settings before using the device. The user can operate the machine immediately once the installation has been finished. The device has the following automatic functions for photo shooting and processing when equipped with our Mediview software: Wide Dynamic Range Meibomian Glands Examination Auto Exposure Auto Gain Auto White Balance Auto OS/OD...

Open the catalog to page 2
S390L (Firefly WDR) - 3

Optical resolution increased by 40% High-quality optical microscope with extraordinary resolution to meet doctors' higher optical quality requirements for better accuracy and safe diagnostic results Built-in yellow filter The Meibomian glands examination

Open the catalog to page 3
S390L (Firefly WDR) - 4

Convenient Patient Management The patient management system enables clinicians to build and edit patient record,search information by inputting keywords.Clinicians can easily record symptoms and manage the data all the time. The software supports DICOM which makes the images captured by Firefly be easily integrated into hospital's medical system. Functional Image Analysis Clinicians can measure the pathology area with our powerful software tools and change the contrast and brightness of the images. Clinicians can also compare several images at one time to analyze the symptoms and pathology....

Open the catalog to page 4
S390L (Firefly WDR) - 5

The Most Effective Tools for Dry Eye Meibomian Gland Observation Tear Film Break-up Time Built-in infrared light source allows the doctor to accurately judge the absence of the meibomian glands. High-performance digital module, doctors can get the tear film break-up time and judge the stability of it by high-resolution video recording. Red Eyes Analysis and Keratopathy Exposure Tear Meniscus Height With a built-in yellow filter, doctors can accurately analyze eye surface damage and inflammation images. Doctors can obtain tear meniscus height by using measuring function in the Mediview...

Open the catalog to page 5
S390L (Firefly WDR) - 6

Microscope Microscope Type Magnification Change Total Magnification Eyepieces Angle between Eyepieces Pupillary Adjustment Diopter Adjustment Field of View Slit Illumination Slit Width Slit Length Aperture Diameters Slit Angle Slit Inclination Filters Lamp Luminance 0~14mm continuous (slit becomes a circle at 14mm) 1~14mm continuous 014mm, 010mm, 05mm, 03mm, 02mm, 01mm, 00.2mm 0°~180° 5°, 10°, 15°, 20° Heat-absorbing filter, ND filter, Red-free filter, Cobalt Blue filter,Yellow filter built-in 3V LED Module > 150KLX Power Supply Input Voltage Input Frequency Power Consumption Output Voltage...