1. Catalogs
  2. Medlere Limited
  3. Platelet Aggregation Analyzer

Platelet Aggregation Analyzer
1 /2Pages

Platelet Aggregation Analyzer

Platelet Aggregation Analyzer
1 /2Pages

Catalog excerpts

Platelet Aggregation Analyzer-1

Platelet Aggregation Analyzer Thrombosis and hemostasis have close correlation to blood platelet function, and 80% of the clot strength depends on platelet, therefore measurement on platelet function is essential. Light Transmission Aggregometry (LTA) is gold standard for platelet function measurement, suitable for clinical fast detection, and suitable for monitoring anti-platelet therapy. 1. Application in anti-platelet therapy: specific monitoring of administration of aspirin by AA specific monitoring of administration of clopidogrel by ADP 2. Assistant diagnosis of thrombosis, miocardial infarction, cerebral thrombosis, angina pectoris, hypertension, diabetic hyperlipemia 3. Detection of threatened abortion 4. Assistant diagnosis on genetic platelet deficiencies based on different reagents as shown in table Thrombocytasthenia Bernard-Soulier syndrome Fast sample measurement (40 tests/hour) Accuracy and reliability in measurement results Automatization and standardization in operation Walk-away operation and facilitated result acquirement light source Normal Normal Platelet storage pool deficiency 5. Assistant diagnosis on acquired disorders, uremia, MDS, hepatocirrhosis 6. Detection of vWF deficiency caused von Willebrand disease (vWD), which results in platelet adhesion, by using specific reagent of RIS. 1 Instrument, 1 Cuvette, Multiple reagents - Automatic measurement reagent receptor reagent platelet thrombus fibrinogen receptor (IIb/IIIa)

 Open the catalog to page 1
Platelet Aggregation Analyzer-2

Platelet Aggregation Analyzer vascular injury collagen exposure platelet adhesion endogenus blood coagulation system platelet release platelet aggregation tissue factor endogenus blood coagulation system platelet thrombus(pale thrombus) thrombosis and hemostasis Analytical modes Light Transmission Aggregometry (LTA) Test velocity Test channel Temperature control automatic sample injection, washing, temperature controlling, magnetic stirring and liquid level tracking 30 groups - 60 positions for platelet-rich plasma (PRP) 250 ul/T and platelet-poor plasma (PPP) 250 ul/T 5 positions with cooling...

 Open the catalog to page 2

All Medlere Limited catalogs and technical brochures

  1. FiCA-II

    4  Pages

  2. FiCA Mate

    2  Pages

  3. FiCA-I

    4  Pages

*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.