Remote Connection: The system supports remote connections for docking stations, infusion pumps, and syringe pumps, with a maximum connection capacity of 64 docking stations or 512 infusion and syringe pumps. Connections can be established via wired or wireless methods.
Unified Parameter Setting: Infusion parameters can be set at the hospital department level and delivered to all docking stations.
Access Management: The system allows for hierarchical login and operation permissions to ensure data security.
Data Collection: Automatically identifies and collects data from connected docking stations, infusion pumps, and syringe pumps.
Infusion Monitoring: Provides real-time display of the running status of syringe and infusion pumps, including drug information.
Infusion Management: Features auto-sorting of remaining infusion time and displays alarm information, drug name, infusion rate, and remaining time.
Central Alarm: Supports remote alarms for syringe and infusion pumps.
Drug Library Management: Allows editing, storing, importing, and exporting of the drug library.
Total Volume Statistics: Offers digital and graphic display options, with support for printing or exporting data.
Data Statistics: Supports exporting or printing reports such as fluid balance and event logs.
Data Transmission: Customizable data transmission protocols for integration with third-party systems.
Display: An optional 22-inch central display is available.
Network Switch: Features a 10/100M adaptive switch with at least 24 interfaces and an optional wireless router.
Note: Functions marked with an asterisk (*) are optional and require a configuration with a display to be utilized.
See more

Catalog excerpts

Central Station IMS50 Parameters-1

Central Station IMS50 Parameters Remote Connection Max. Connection Supports remote connection of the docking stations, infusion pumps and syringe pumps. No less than 64 units docking station, or 512 units of infusion pumps and syringe pumps. Connection Method Wired or wireless Unified Parameter Hospital Dept. infusion parameters can be set and delivered to all docking Setting stations. Access Can set login and operation permissions hierarchically to ensure data security Management Data Collection Identify connected docking stations or infusion pumps & syringe pumps, and collect data automatically. Infusion Monitoring Real-time display of syringe pump or infusion pump running status and drug in use information etc. Infusion Auto-sorting of remaining infusion time, display alarm information. Management Auto-display Drug name, infusion rate, remaining time etc. Central Alarm* Support syringe pump and infusion pump remote alarm. Drug Library Can edit, store, import and export drug library. Management* Total volume Digital and graphic display, support print or export data statistics* Data Statistics* Support reports like fluid balance, event logs, etc.to be exported or printed. Data transmission* Can customize data transmission protocols for data transmission to third-party systems Display* Optional 22-inch central display Network switch* 10/100M adaptive, no less than 24 interfaces, optional wireless router Notes: Optional items are with *, only configuration with display can achieve those functions.