ADAPTA™ DR PACING SYSTEM
5Pages

{{requestButtons}}

Catalog excerpts

ADAPTA™ DR PACING SYSTEM - 1

ADAPTA™ DR PACING SYSTEM Models ADDR01, ADDR03, ADDR06, ADDRS1, ADDRL1 Physical characteristics1 Physical characteristics Volume Model ADDR01 Battery Type Voltage Usable Capacity 11.3 yearsd 12.4 yearse with MVP™ On 8.5 yearsd 9.4 yearse with MVP™ On 14.0 yearsd 15.4 yearse with MVP™ On Parylene coating on backside of case. Capacity from Beginning of Service (BOS) to End of Service (EOS). Current serial number prefixes begin with “NW,” older model serial number prefix is “PW.” Clinician should consult labeling for relevant longevity information. d DDDR or DDD, 60 bpm, 100% pacing, ventricle 2.0 V,† atrial 1.5 V,†† 0.4 ms pulse width, 1,000 Ω pacing impedance e MVP™ Mode ON — 50% atrial pacing and 5% ventricular pacing. † Lower rate of 30 not available in MVP™ Mode †† ACM and VCM minimum adapted values at out-

Open the catalog to page 1
ADAPTA™ DR PACING SYSTEM - 2

Therapies for intrinsic activation Parameter Programmable values Programmable parameters Programmable values MVP™ Modes Pacing Modes DDDR; DDD; DDIR; DDI; DVIR; DVI; DOOR; DOO; VDD; VVIR; VDIR; VVI; VDI; VVT; VOOR; VOO; AAIR; ADIR; AAI; ADI; AAT; AOOR; AOO; ODO; OVO; OAO Max increase to AV Sinus Preference Sinus Preference Zone Search Interval Mode Switch Lower Rate Sleep Rate Upper Tracking Rateb Upper Sensor Rate Wake Time Rate Response Pacing Atrial Sensitivity Programmable values Ventricular Sensitivity Rate Profile Optimization Bipolar; Unipolard; Configure Bipolar; Unipolard;...

Open the catalog to page 2
ADAPTA™ DR PACING SYSTEM - 3

Atrial tachyarrhythmia therapies and interventions2 Automatic pacing, sensing, and lead monitor2 Mode switch Implant detection and initialization At the completion of the 30-minute Implant Detection period, MVP™ modes are enabled; Rate Profile Optimization is enabled; the appropriate pacing and sensing polarities are automatically selected by the device; Atrial and Ventricular Capture Management™ is enabled and Amplitude and Pulse width become Adaptive. Sensing Assurance is enabled and sensitivity becomes Adaptive. Programmable values Mode Switch Detected rate Detect duration Programmable...

Open the catalog to page 3
ADAPTA™ DR PACING SYSTEM - 4

Highlights significant events, AT/AF and Pacing Summary, Threshold and Impedance Trends Atrial and Ventricular Pacing Threshold Trends Battery Longevity Pacing Summary and Access to Rate Histogram Atrial and Ventricular Lead Impedance Trends Number of Hours/Day in Atrial Arrhythmia, Percentage of Time Access to Atrial Arrhythmia Diagnostics Observations P-Wave/R-Wave Amplitudes and Access to A and V Sensitivity Trends Trend data compiles up to 6 months of daily clinical information in an easy-to-interpret graphic format Telemetry Features Transtelephonic Monitor Extended Telemetry Extended...

Open the catalog to page 4
ADAPTA™ DR PACING SYSTEM - 5

References 1 Medtronic Adapta Implant Manual. M960723A001. Accessed June 14, 2017. 2 Medtronic Adapta™, Versa™, Sensia™, Relia™ Pacemaker Reference Guide, M965319A001 C. Accessed June 26, 2017. Brief Statement IPGs Indications Implantable pulse generators (IPGs) are indicated for rate adaptive pacing in patients who may benefit from increased pacing rates concurrent with increases in activity. Pacemakers are also indicated for dual chamber and atrial tracking modes in patients who may benefit from maintenance of AV synchrony. Dual chamber modes are specifically indicated for treatment of...

Open the catalog to page 5

All Medtronic catalogs and technical brochures

  1. EverFlex™

    4 Pages

  2. Micra™

    12 Pages

  3. Provia™

    4 Pages

  4. Intuition™

    3 Pages

  5. 5392

    2 Pages

  6. Evolut™ PRO+

    12 Pages

  7. SOLOIST™

    2 Pages

  8. BIS

    16 Pages

Archived catalogs

  1. MicroFrance®

    166 Pages

  2. HMS Plus

    6 Pages

  3. Endurant II

    8 Pages

  4. StealthViz

    4 Pages

  5. ENT product

    476 Pages

  6. Parts catalog

    15 Pages