video corpo

CSF Management, Critical Care, Cranial Repair, and Neuroendoscopy
130Pages

{{requestButtons}}

Catalog excerpts

CSF Management, Critical Care, Cranial Repair, and Neuroendoscopy - 1

PRODUCTS CATALOG CSF Management, Critical Care, Cranial Repair, and Neuroendoscopy

Open the catalog to page 1
CSF Management, Critical Care, Cranial Repair, and Neuroendoscopy - 3

TABLE OF CONTENTS Contents . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Page Hydrocephalus Therapy. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5 Critical Care. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 69 Neuroendoscopy . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . ....

Open the catalog to page 3
CSF Management, Critical Care, Cranial Repair, and Neuroendoscopy - 5

HYDROCEPHALUS THERAPY Contents Valves. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6 Catheters. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 16 Shunts . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 30 Lumboperitoneal shunts. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . ....

Open the catalog to page 5
CSF Management, Critical Care, Cranial Repair, and Neuroendoscopy - 6

VALVES The StrataVarius™ Adjustment System is a battery-powered, handheld instrument that senses the location and orientation of the magnet contained in any Strata-type adjustable valve. The StrataVarius works in conjunction with the StrataVarius Adjustment Tool to change the magnet orientation, and thus the Performance Level (PL) setting of the valve. StrataVarius™ Adjustment System Included with Product: §§ StrataVarius System §§ Adjustment Tool §§ Strata II Smart Card §§ Strata NSC Smart Card §§ Storage/Carrying Case §§ X-Ray Templates §§ Instruction Manual Product Description 45806...

Open the catalog to page 6
CSF Management, Critical Care, Cranial Repair, and Neuroendoscopy - 7

VALVES StrataMR™ Adjustment Tools are used to non-invasively adjust and verify the performance level setting of StrataMR valves pre-op and post-op. Not compatible with Strata™ II or Strata™ NSC valves. HYDROCEPHALUS THERAPY StrataMR Valve Adjustment Tools Indicator Tool Locator Tool Adjustment Tool Dimensions included in this catalog are for reference only.

Open the catalog to page 7
CSF Management, Critical Care, Cranial Repair, and Neuroendoscopy - 8

VALVES The Strata II valve was created to allow for preoperative and noninvasive postoperative pressure level adjustments. This adjustment ability is intended to reduce both the potential trauma and cost a patient might endure as a result of valve revisions relating to pressure changes. Neither the finished product, nor materials used during manufacture of product, contain latex. The exterior surface of the Strata II valve with BioGlide is surface modified with a covalently bonded hydrogel. (The exterior of the Delta Chamber mechanism is not surface modified so as not to interfere with...

Open the catalog to page 8
CSF Management, Critical Care, Cranial Repair, and Neuroendoscopy - 9

VALVES The Strata™ NSC valve was created to allow for preoperative and noninvasive postoperative pressure level adjustments. This adjustment ability is intended to reduce both the potential trauma and cost a patient might endure as a result of valve revisions relating to pressure changes. Neither the finished product, nor materials used during manufacture of product, contain latex. HYDROCEPHALUS THERAPY The exterior surface of the Strata NSC valve with BioGlide™ is surface modified with a covalently bonded hydrogel. The exterior surface has hydrophilic properties for enhanced lubricity....

Open the catalog to page 9
CSF Management, Critical Care, Cranial Repair, and Neuroendoscopy - 10

VALVES The Strata™ NSC LP valve is sized for subcutaneous placement in a lumboperitoneal (LP) shunt. It features an integral lumbar connector and strain relief for easy, non-kinking attachment of the proximal lumbar catheter. The larger valve flange allows the user to suture the valve up to the dermal layer. Neither the finished product, nor materials used during manufacture of product, contain latex. Strata NSC LP Valve Product Description 44465 CSF Management, Critical Care, Cranial Repair and Neuroendoscopy Products Catalog

Open the catalog to page 10
CSF Management, Critical Care, Cranial Repair, and Neuroendoscopy - 11

VALVES The Delta™ valve is designed to minimize overdrainage of CSF and maintain intraventricular pressure (IVP) within a normal physiologic range, regardless of patient position. The normally closed Delta chamber mechanism opens in response to positive intraventricular pressure. Working with the membrane valve, this mechanism minimizes overdrainage by utilizing the principle of hydrodynamic leverage. HYDROCEPHALUS THERAPY All Delta valves incorporate an injectable reservoir dome, occluders for selective flushing, and a non-metallic design. The valves are fabricated of dissimilar materials...

Open the catalog to page 11
CSF Management, Critical Care, Cranial Repair, and Neuroendoscopy - 12

VALVES Delta Valve, Regular Product Performance Level Delta Valve, Small Product Performance Level CSF Management, Critical Care, Cranial Repair and Neuroendoscopy Products Catalog

Open the catalog to page 12
CSF Management, Critical Care, Cranial Repair, and Neuroendoscopy - 13

VALVES Delta Valve, Neonatal Product Performance Level HYDROCEPHALUS THERAPY Delta Valve, Burr Hole Product Dimensions included in this catalog are for reference only.

Open the catalog to page 13
CSF Management, Critical Care, Cranial Repair, and Neuroendoscopy - 14

VALVES CSF-Flow Control valves (Contoured valves) are fabricated of dissimilar materials — polypropylene and silicone elastomer — reducing valve sticking and deformation. The internal flow path, combined with the membrane valve design, contribute to optimum valve performance. Each valve is individually tested to ensure conformance with individual flow characteristics. All valve designs include integral connectors to facilitate catheter connection. The contoured, burr hole, and ultra small models include central reservoirs with needle guards for percutaneous CSF access. One or two flushing...

Open the catalog to page 14
CSF Management, Critical Care, Cranial Repair, and Neuroendoscopy - 15

VALVES CSF-Flow Control Valve, Contoured Small Product 27102 Low-Low 42312 Low 42314 Medium 42316 High 92312 Low with BioGlide 92314 Medium with BioGlide 92316 High with BioGlide HYDROCEPHALUS THERAPY Pressure Description CSF-Flow Control Valve, Ultra Small Product Pressure 42410 Low-Low 42412 Low 42414 Medium CSF-Flow Control Valve, Button Included with product: • Straight Connector (not shown) Product Pressure 24003 LL 24003 L 24003 M CSF-Flow Control Valve, Burr Hole Product Pressure Low Medium High Low Medium High Dimensions included in this catalog are for reference only.

Open the catalog to page 15

All Medtronic catalogs and technical brochures

  1. EverFlex™

    4 Pages

  2. Micra™

    12 Pages

  3. Provia™

    4 Pages

  4. Intuition™

    3 Pages

  5. 5392

    2 Pages

  6. Evolut™ PRO+

    12 Pages

  7. SOLOIST™

    2 Pages

  8. BIS

    16 Pages

Archived catalogs

  1. MicroFrance®

    166 Pages

  2. HMS Plus

    6 Pages

  3. Endurant II

    8 Pages

  4. StealthViz

    4 Pages

  5. ENT product

    476 Pages

  6. Parts catalog

    15 Pages