video corpo

PURITAN BENNETT ™
12Pages

{{requestButtons}}

Catalog excerpts

PURITAN BENNETT ™ - 1

HELP THEM BREATHE MORE NATURALLY Medtronic Further, Together

Open the catalog to page 1
PURITAN BENNETT ™ - 2

Your patients’ comfort matters. That’s why we designed the Puritan Bennett™ 980 ventilator with some of the most innovative breathdelivery technology available. Simple. Smart. Safe. Because helping your patients breathe more naturally† may make them more comfortable, too.1 †Compared to conventional mechanical ventilation (VC,VC+

Open the catalog to page 2
PURITAN BENNETT ™ - 3

Simple ■ Innovative user interface ■ Customizable display ■ Intuitive screen navigation Smart ■ Advanced synchrony tools let you set the ventilator to adapt to each patient's unique needs ■ These synchrony tools help provide the right level of support throughout each breath Safe ■ Unique ventilator assurance feature* ■ Integrated expiratory filtration system

Open the catalog to page 3
PURITAN BENNETT ™ - 4

LET’S WORK TOGETHER TO REDUCE DISCOMFORT IN THE ICU Being in the ICU can be unsettling and uncomfortable for patients. With limited consciousness and limited ability to communicate, patients have little control over their own comfort.2,3 Machines and clinicians may need to assume control over the most instinctive decisions patients have made all their lives, including:4 ∙∙When to eat and move around ∙∙How to moderate their body temperature ∙∙When and how they breathe, if they are being mechanically ventilated It’s easy to see why 71 percent of ICU patients show signs of agitation at least...

Open the catalog to page 4
PURITAN BENNETT ™ - 5

AN EXAMPLE OF THE VICIOUS CYCLE OF ASYNCHRONY Ventilation is sometimes necessary. But conventional modes of ventilation can’t always match your patients’ breathing patterns or properly manage their work of breathing. This can make them agitated. And without a better way to manage agitation, sedation can seem like the only option. In fact, one study reported that 42 percent of all increases in sedation are responses to patientventilator asynchrony.5,6 Respiratory muscle atrophy begins in as little as What’s more, an increase in sedation can lead to longer ventilator dependency.2, 3 That’s...

Open the catalog to page 5
PURITAN BENNETT ™ - 6

PATIENTS FACE ENOUGH CHALLENGES IN THE ICU. TRYING TO BREATHE SHOULDN'T BE ONE OF THEM. Our advanced synchrony tools adapt to each patient's unique needs — and provide the appropriate level of support throughout the breath, from initiation to completion. With calculations happening every 5 milliseconds, the Puritan Bennett™ 980 ventilator stays in tune with patients' demands. It helps them receive the flow and volume they want — when they want it, from breath to breath.

Open the catalog to page 6
PURITAN BENNETT ™ - 8

HELPING PATIENTS DICTATE BREATHS PAV™*+ Software With PAV™*+ software, patients define the rate, depth, and timing of each breath they receive. It can: ∙∙ Help you clearly understand the work required to complete each breath ∙∙ Tell the ventilator when patients want to begin inspiration, how deep the breath should be, when to end the breath, and how often the patient needs to breathe ∙∙ Continuously measure patient demand by reading flow and volume every 5 milliseconds ∙∙ Change ventilatory support within the same breath as patient demand changes When you set the % support within PAV™*+...

Open the catalog to page 8
PURITAN BENNETT ™ - 9

HELPS PREVENT AUTO-TRIGGERING AND ASYNCHRONY Leak Sync software Leaks from a mask interface or uncuffed endotracheal tube are common during mechanical ventilation.11-13 And that can cause auto-triggering and asynchrony. Leak Sync software can help: ∙∙Detect changes in breathing ∙∙Compensate for leaks ∙∙Adjust effective trigger sensitivity, helping manage the patient’s WOB5,10 Published study Puritan Bennett™ ventilator leak compensation performance during both invasive and noninvasive ventilation14 Invasive mechanical ventilation ∙∙The Puritan Bennett 980 ventilator is one of only two...

Open the catalog to page 9
PURITAN BENNETT ™ - 10

PEACE OF MIND. FOR YOU. FOR YOUR PATIENTS. The Puritan Bennett™ 980 ventilator is built on the reliability and sophisticated breathdelivery technology you have come to expect from this portfolio. With features you can depend on, including: ∙∙NeoMode 2.0 software: Helps you provide ventilatory support to neonates weighing as little as 300 grams by delivering tidal volumes as small as 2 mL ∙∙Noninvasive software: Allows versatile options, including SIMV and CPAP ∙∙BiLevel software: Permits spontaneous breathing at all times and supports biphasic or airwaypressure release ventilation for extra...

Open the catalog to page 10
PURITAN BENNETT ™ - 11

EXPERIENCE. RELIABILITY. SERVICE. Quality Our service team worked hand-in-hand with design engineers during the development of the Puritan Bennett™ 980 ventilator. So they can provide the high-quality service that you have come to expect. Consistency Our service team operates on a solid foundation of experience and expertise, with more than 50 years of experience with Puritan Bennett™ ventilators. Responsiveness With more than 40 customer support engineers across the country, our fully integrated sales, service, and clinical support team lets us respond quickly to your needs. Integrity We...

Open the catalog to page 11
PURITAN BENNETT ™ - 12

1. Grasso S, Puntillo F, Mascia L, et al. Compensation for increase in respiratory workload during mechanical ventilation. Pressure-support versus proportionalassist ventilation. Am J Respir Crit Care Med. 2000;161(3 Pt 1):819-826. 2. Siegel MD. Management of agitation in the intensive care unit. Clin Chest Med. 2003;24(4):713-725. 3. Tate JA, Devito Dabbs A, Hoffman LA, Milbrandt E, Happ MB. Anxiety and agitation in mechanically ventilated patients. Qual Health Res. 2012;22(2):157-173. 4. Patak L, Gawlinski A, Fung NI, Doering L, Berg J, Henneman EA. Communication boards in critical care:...

Open the catalog to page 12

All Medtronic catalogs and technical brochures

  1. EverFlex™

    4 Pages

  2. Micra™

    12 Pages

  3. Provia™

    4 Pages

  4. Intuition™

    3 Pages

  5. 5392

    2 Pages

  6. Evolut™ PRO+

    12 Pages

  7. SOLOIST™

    2 Pages

  8. BIS

    16 Pages

Archived catalogs

  1. MicroFrance®

    166 Pages

  2. HMS Plus

    6 Pages

  3. Endurant II

    8 Pages

  4. StealthViz

    4 Pages

  5. ENT product

    476 Pages

  6. Parts catalog

    15 Pages