VISIA AF MRI™ S VR SURESCAN™ Model DVFC3D1
7Pages

{{requestButtons}}

Catalog excerpts

VISIA AF MRI™ S VR SURESCAN™ Model DVFC3D1 - 1

VISIA AF MRI™ S VR SURESCAN™ Model DVFC3D1 Product specifications Physical characteristics Volumea Surface area of device can Materials in contact with human tissuec Titanium, polyurethane, silicone rubber Battery chemistry Hybrid CFx lithium/silver vanadium oxide Battery model Volume with connector ports unplugged. b The radiopaque ID and Medtronic radiopaque identifier can be viewed in a fluoroscopic image of the device. c These materials have been successfully tested for the ability to avoid biological incompatibility. The device does not produce an injurious temperature in the surrounding tissue during normal operation. a Replacement indicators Recommended Replacement Time (RRT) < 2.73 V on 3 consecutive daily automatic measurements Maximum energy levels and typical full energy charge times Maximum programmed energy Maximum delivered energya,b 36 J Maximum stored energyc Typical charge time at Beginning of Service (BOS)d Typical charge time at Recommended Replacement Time (RRT)d a Energy delivered at connector block into a 50 Ω load. For 35 J programmed energy, delivered energy exceeds 35 J. Energy stored at charge end on capacitor. d Charge time during a nonwireless telemetry session may be slightly higher. b c § MR Conditional with PhysioCurve™ Design § SmartShock™ Technology § Complete Capture Management™ § AF Diagnostics

Open the catalog to page 1
VISIA AF MRI™ S VR SURESCAN™ Model DVFC3D1 - 2

Device parameters Ventricular tachyarrhythmia therapy parameters Parameter Tachyarrhythmia detection parameters Parameter Programmable values VF Initial Beats to Detect FVT Interval (Rate) VT Detection VT Interval (Rate)a VT Initial Beats to Detect AX>B; B>AX Rx1-Rx4: B>AX ; Rx5-Rx6: AX>B During Charging ; Before Charging; Off Therapy Type Burst ; Ramp; Ramp+ On ; Off Programmable values VT Monitor Interval (Rate)a Monitored VT Beats to Detect Switch when number of consecutive ATP successes equals Smart Mode VT/FVT Therapy parameters Match Threshold Therapy Type CV; Burst; Ramp; Ramp+ Rx1:...

Open the catalog to page 2
VISIA AF MRI™ S VR SURESCAN™ Model DVFC3D1 - 3

Ventricular tachyarrhythmia therapy parameters, cont’d. Programmable values Programmable values Ramp+ therapy parameters … 15 Initial # Pulses Smart Modeb This setting applies to all sensing in this chamber for both tachyarrhythmia detection and bradycardia pacing operations. RV Capture Management™ parameters Parameter Shared Settings V-V Minimum ATP Interval Programmable values RV Amplitude Safety Margin RV Minimum Adapted Amplitude RV Acute Phase Remaining Blanking periods Progressive Episode Therapies Active Can™/SVC Coil If the Active Can/SVC Coil parameter is set to Can Off, the Active...

Open the catalog to page 3
VISIA AF MRI™ S VR SURESCAN™ Model DVFC3D1 - 4

Post VT/VF shock pacing parameters Number of Shocks Delivered in an Episodec Device Tone Programmable values Post VT/VF Shock Pacing Overdrive Rate Overdrive Duration Alert Enable – Urgency … 120 bpm Patient Home Monitor Shared (Device Tone and Patient Home Monitor) Number of Shocks Thresholda Programmable values Post Shock V. Amplitude Post Shock V. Pulse Width Alert Enableb Post shock pacing parameters Parameter All Therapies in a Zone Exhausted for an Episode Device Tone Alert Enable – Urgency Patient Home Monitor Sleep parameters Parameter Programmable values Sleep Rate Wake Time Alert...

Open the catalog to page 4
VISIA AF MRI™ S VR SURESCAN™ Model DVFC3D1 - 5

Lead/Device integrity alerts, cont’d. RVtip to RVcoil; RVtip to RVring Stored (Ventricular) EGM1 and EGM2 ; EGM1 and EGM3; EGM1 and LECG; EGM2 and EGM3; EGM2 and LECG; EGM3 and LECG Stored (Atrial) EGM1 and LECG; EGM2 and LECG ; EGM3 and LECG Off ; On – 1 month; On – 3 months; On Continuous Excessive Charge Time EOS Device Date/Timed (enter time and date) Device Tone Holter Telemetry Programmable values SVC Defibrillation Impedance Less than SVC Defibrillation Impedance Greater than Low Battery Voltage RRT Device Tone Alert Enable – Urgency Patient Home Monitor Alert Enable Alert Enable –...

Open the catalog to page 5
VISIA AF MRI™ S VR SURESCAN™ Model DVFC3D1 - 6

Manual defibrillation parameters Parameter Parameter Resume at Deliver Enabled ; Disabled Enabled; Disabled AX>B; B>AX If the Active Can/SVC Coil parameter is set to Can Off, the Active Can electrode is not used as part of the high-voltage delivery pathway. If the Active Can/SVC Coil parameter is set to SVC Off, the SVC Coil electrode is not used as part of the high-voltage delivery pathway. Selectable values Monophasic ; Biphasic AX>B; B>AX If the Active Can/SVC Coil parameter is set to Can Off, the Active Can electrode is not used as part of the high-voltage delivery pathway. If the...

Open the catalog to page 6
VISIA AF MRI™ S VR SURESCAN™ Model DVFC3D1 - 7

Longevity Projected service life in years Projected service life in years Pacing Mode, percent pacing Pacing Amplitude Brief Statement Visia AF MRI™ S VR DVFC3D1 The Visia AF MRI S VR SureScan™ ICD is MR Conditional and, as such is designed to allow patients to be safely scanned by an MRI machine when used according to the specified MRI conditions for use. When programmed to On, the MRI SureScan feature allows the patient to be safely scanned while the device continues to provide appropriate pacing. The Visia AF MRI SureScan system automatically detects and records the occurrence of atrial...

Open the catalog to page 7

All Medtronic catalogs and technical brochures

  1. EverFlex™

    4 Pages

  2. Micra™

    12 Pages

  3. Provia™

    4 Pages

  4. Intuition™

    3 Pages

  5. 5392

    2 Pages

  6. Evolut™ PRO+

    12 Pages

  7. SOLOIST™

    2 Pages

  8. BIS

    16 Pages

Archived catalogs

  1. MicroFrance®

    166 Pages

  2. HMS Plus

    6 Pages

  3. Endurant II

    8 Pages

  4. StealthViz

    4 Pages

  5. ENT product

    476 Pages

  6. Parts catalog

    15 Pages