MEGASAN Medikal entered the sector in 1981 with assembly and maintenance works and started production in 1998. It continues its activities in its production facility Our aim; By closely following scientific and technological established on a total area of 70 thousand m 2 with developments and following a policy parallel to the a closed area of 14 thousand m 2. There is also a globalization process in the world, we aim to maintain showroom in Ankara where the R&D and sales our leading position in our sector and become a more departments are located. Today, MEGASAN Medikal respected company around...
Open the catalog to page 2Description Input for Hospital Pipeline High Pressure Valve (Sintered Filter) Flexible High Pressure Connection High Pressure Collector Liquid Tank or Spare Manifold Connection Distribution Manifold Block Change-Over (Automatic Side Changer) Discharge Valve Cylinder Holders CAMGP High Pressure Reducers ensure that the pressure of medical gases (O2, CO2, N2O, compressed air) coming at high pressure (230 bar) through collectors connected to gas cylinders is adjusted to the required pressure values and safely supplied to the installation. It is mostly reduced to 4-8 Bar values. Intended Use: By...
Open the catalog to page 3Fully Automatic High Pressure Reducer Stations And Equipment Technical Specifications Product Code : MG-YBDNx “x:O (Oxygen), A (N2O), SA (Pure Nitrogen), KG (Mixed Gas), K (CO2), Product Name : Fully Automatic High Pressure Reducer Unit Input Pressure Output Pressure : 4 – 7 Bar Capacity Input Number : 4 (Primary Ramp, Spare Ramp, External Supply Point, Emergency Supply Point) Operating Temperature Value : (+10) - (+45) C° Power Supply Package Type Package Sizes Alarm System : Digital LCD, Alarm, Voice Alert, Touch Screen Alarm Panel (optional) Connection Type : 2xModBus 1- High Pressure Reducer...
Open the catalog to page 4OPTIONAL FEATURES Features Alternative Supply Elimination of the need for additional control panel by adding inlet for liquid tank and generator connection. Distribute, Cut, Spare While safe gas distribution is provided to the required areas thanks to the collector system it contains; The line to be serviced, maintained or any repaired is safely repaired by stopping the gas passage thanks to the relevant distribution collector system, and while this process is being carried out, the gas flow in other distribution lines continues safely. In addition, any malfunctions that may occur on the pipeline...
Open the catalog to page 5Single High Pressure Reducer Unit Intended Use: It ensures that the pressure of the medical gases needed in hospital installations is brought to the ideal values and the installation is fed. In general, it acts as a backup of the fully automatic oxygen plant. It is connected to the installation of the relevant gas with bypass in parallel with the fully automatic high pressure converter. It ensures the continuity of the supply of the installation in case of failure or servicemaintenance of the fully automatic high pressure reducer. It can also be used individually in places that do not require...
Open the catalog to page 6Oxygen Liquid Tank (LOX) Equipments Change Over Panels Intended Use: It is a system that automatically activates the backup system in case of any problem in the liquid tanks used in the supply of the hospital installation. It makes the gas flow uninterrupted. Chemical compatibility Isolation plugs before use Insulation Separator Mechanical Reading Alarm Unit (optional) Technical Specifications Product Code Product Name : Liquid - Cylinder Cycle Unit Input - Output Pressure Input Number : 4 Pieces (Primary Ramp, Spare Ramp, External supply point and Emergency supply socket) Operating Temperature...
Open the catalog to page 7Oxygen Generator (PSA) Equipments Generator- Cylinder Changover Unit Intended Use When there is any problem in the O2 production system, the backup system is activated without the need for intervention. Technical Specifications Product Code Product Name : Generator - Cylinder Cycle Unit Input - Output Pressure Input Number : 2 (Primary Ramp, Spare Ramp) Operating Temperature Value Power Supply Package Type Package Sizes Package Weight Alarm System : Visual and Sensory Alarm Chemical compatibility Isolation plugs before use Insulation Separator Mechanical Reading Alarm Unit These are the systems...
Open the catalog to page 8General Features OPTIONAL FEATURES Input Filter Thanks to the newly designed filter system, the diameter narrowing in the gas inlets is prevented and the possible particles that may enter the power plant from the gas sources are retained, thus extending the life of the power plant. *There is a small filter inside, since the filter clogs quickly, a large size filter is recommended. Functional Alarm System A 7” alarm system that can be added on the panels at any time, can show the pressure value in the ramps, gives visual and audible alarms, can repeat the alarms given and keep them under record,...
Open the catalog to page 9General Features Chemical Compatibility All gas contact surfaces are made of copper, brass and gaskets which are compatible with all medical gases, including oxygen. All types of medical gases do not react to the materials they are passing through. Discharge Line In cases where there is a sudden increase in pressure inside the product, it ensures the safe operation of the system by evacuating the high pressure wave in a pressure-sensitive manner, while ensuring that the environment where the product is located is safe by discharging these flammable gases outside the building. Beautiful in its...
Open the catalog to page 10Supply Collectors for Cylinder Systems Technical Data It provides fast and safe Product Code connection of high pressure cylinders feeding medical gas plants through flexible copper volume with 2-5 high pressure cylinder connection options. Technical Specifications Product Code : MG-KOLxy “x:O (Oxygen), A (N2O), SA (Pure Nitrogen), K (Carbon Dioxide), H (Dry Air), “ Product Name : Cylinder Supply Unit Collector Package Type Check-Valve Safety System It prevents the line from discharging Drain Valve It manually evacuates the medical gases remaining in the collector system during maintenance and...
Open the catalog to page 1115 Pages
5 Pages
108 Pages