MELAquick 12+ - 6 Pages

Add to MyMedicalExpo favorites
MELAquick 12+

Catalog excerpts

Compact. Fast. Strong.

 Open the catalog to page 1

The requirement. Requirements for the preparation of dental instruments are defined by official hygiene experts. Instruments for “semicritical” use (restorative treatment) have to be prepared and treated after each patient, preferably in a validated, mechanised disinfection and cleaning process. If no mechanical prepa­ ation and treatment process is used, a manual process r can be selected, but it has to be concluded with sterilization of the instruments. “Critical” hand pieces and turbines used for paradontological, endodontic and surgical treatment have to be sterilized at the end of the...

 Open the catalog to page 2

Example of loading with unwrapped instruments Example of loading with wrapped instruments High quality preparation­ . Big inside  — small outside. Both air removal and drying are of the utmost importance in the sterilization of handpieces and turbines. The fractionated gravity­ method creates the ideal conditions for sterilization safety in accordance­with European Standard 13060 — programs in line with the standard. Drying takes place by connecting the MELA quick®12+ to the compressed air supply of the practice in the preparation room. To protect the instruments and to preserve the value...

 Open the catalog to page 3

Operation  — no compromises. Universal basket on a frame Small parts insert for universal basket All programs and options can be selected easily and quickly using the four soft keys found on the display. Support with ISO adapters on a frame The programs  — fast and multifunctional. Three class S programs are provided : One Quick-Program for unwrapped instruments and two programs for wrapped instruments. All programs in accordance with the European Standard 13060. Programs Packaging Sterilization time Operating time* Drying Loading** Quick-Program S unwrapped 3.5 min at 134 ºC 6 – 8 min ~1...

 Open the catalog to page 4

Interfaces and connections. Device fuse —16A gRL Plug on the side for sterile filter (only in MELA quick®12+ p) Device fuse —10 AT Connection for monitoring the feed water container Connection for monitoring the waste water container Serial interface (RS232) for documentation Connection for compressed air (only in MELA quick®12+) Mains connection for IEC plug Connection for external waste water container Spring safety valve Slit for emergency unlocking Connection for external feed water container

 Open the catalog to page 5

MELA  uick®12+ p q The stand-alone device. This innovative device concept can also be used if there is no compressed air connection in the preparation room. MELA quick®12+ p has a compressor pump integrated into the device, which permits operation of the autoclave irrespective of location. The functionality and short operating times are identical in both MELA quick®12+ devices. Documentation and approval. Possibilities for documentation, batch release and re-tracing known from the Pro- and PremiumClass MELAG device series are also available for the MELA quick®12+. Starting with MELA flash...

 Open the catalog to page 6

All MELAG catalogs and technical brochures

  1. MELAcontrol

    6 Pages

  2. MELAtherm®10

    12 Pages

  3. melatronic 23

    4 Pages

  4. MELAstore

    4 Pages

  5. MELAdem®

    8 Pages

  6. Cliniclave 45 M

    12 Pages

  7. MELAquick 12+ p

    6 Pages

  8. MELAtronic EN+

    4 Pages

  9. Pro-Class

    12 Pages

  10. INCUBAT 80 / 85

    1 Pages

  11. CLINICLAVE 45

    4 Pages

  12. Vacuklav 40 B+

    12 Pages

  13. Sterilizer 205

    2 Pages

  14. Sterilizer 75

    2 Pages

  15. MELAseal 100+

    4 Pages

  16. MELAseal 200

    4 Pages

  17. MELAseal Pro

    4 Pages

  18. MELAdem 40

    2 Pages

  19. MELAnet Box

    1 Pages

  20. MELAdoc

    4 Pages

  21. MELAcontrol Pro

    6 Pages

  22. MELAcontrol

    1 Pages

  23. MELAtherm 10

    12 Pages

  24. EUROKLAV +

    12 Pages

  25. S-Class

    12 Pages

  26. Profi-Class

    12 Pages

  27. MELAdest® 65

    2 Pages

  28. MELAdem®40

    2 Pages

  29. MELAtherm®

    4 Pages

  30. MELAtronic®EN

    4 Pages

  31. Cliniklav®25

    12 Pages