Introduction
The MELA quick®12+ is a compact and efficient autoclave designed for the rapid sterilization of dental instruments, meeting hygiene standards for both 'semi-critical' and 'critical' uses. It offers a fast and reliable solution for sterilizing handpieces and turbines, crucial for maintaining hygiene in dental practices.
Specifications
The device requires minimal installation space (20.5 x 45 cm) and includes two 5-litre containers for demineralized and used water. It operates with a fractionated gravity method for air removal and pulsating overpressure drying, ensuring compliance with European Standard 13060. The autoclave is compatible with a 220-240 V electrical supply and has a chamber volume of 1.35 liters.
Programs and Operation
The MELA quick®12+ offers three Class S programs: a Quick-Program for unwrapped instruments and two programs for wrapped instruments, all operating at 134 ºC. The Quick-Program sterilizes in 3.5 minutes with a total operating time of 6-8 minutes. The Universal-Program and Prion-Program cater to wrapped instruments with longer operating times. The device features easy program selection via four soft keys on the display.
Features
The autoclave includes integrated water quality measurement to prevent operation with poor water quality. It supports documentation and batch release through MELA flash and MELA net Box, and can operate without a compressed air connection using the MELA quick®12+ p model, which includes an integrated compressor pump.
Compliance and Standards
The MELA quick®12+ complies with several directives and standards, including the European Directive for Medical Devices (93/42/EEC), Pressure Equipment Directive (97/23/EC), and Machinery Directive (2006/42/EC). It also meets ISO 9001 and ISO 13485 quality management standards.
Conclusion
The MELA quick®12+ is an innovative solution for dental practices, offering fast, efficient, and compliant sterilization of instruments, ensuring high hygiene standards are maintained with minimal operational disruption.
See more

Catalog excerpts

MELAquick 12+-1

Compact. Fast. Strong.

 Open the catalog to page 1
MELAquick 12+-2

The requirement. Requirements for the preparation of dental instruments are defined by official hygiene experts. Instruments for “semicritical” use (restorative treatment) have to be prepared and treated after each patient, preferably in a validated, mechanised disinfection and cleaning process. If no mechanical prepa­ ation and treatment process is used, a manual process r can be selected, but it has to be concluded with sterilization of the instruments. “Critical” hand pieces and turbines used for paradontological, endodontic and surgical treatment have to be sterilized at the end of the reprocessing...

 Open the catalog to page 2
MELAquick 12+-3

Example of loading with unwrapped instruments Example of loading with wrapped instruments High quality preparation­ . Big inside  — small outside. Both air removal and drying are of the utmost importance in the sterilization of handpieces and turbines. The fractionated gravity­ method creates the ideal conditions for sterilization safety in accordance­with European Standard 13060 — programs in line with the standard. Drying takes place by connecting the MELA quick®12+ to the compressed air supply of the practice in the preparation room. To protect the instruments and to preserve the value of...

 Open the catalog to page 3
MELAquick 12+-4

Operation  — no compromises. Universal basket on a frame Small parts insert for universal basket All programs and options can be selected easily and quickly using the four soft keys found on the display. Support with ISO adapters on a frame The programs  — fast and multifunctional. Three class S programs are provided : One Quick-Program for unwrapped instruments and two programs for wrapped instruments. All programs in accordance with the European Standard 13060. Programs Packaging Sterilization time Operating time* Drying Loading** Quick-Program S unwrapped 3.5 min at 134 ºC 6 – 8 min ~1 min...

 Open the catalog to page 4
MELAquick 12+-5

Interfaces and connections. Device fuse —16A gRL Plug on the side for sterile filter (only in MELA quick®12+ p) Device fuse —10 AT Connection for monitoring the feed water container Connection for monitoring the waste water container Serial interface (RS232) for documentation Connection for compressed air (only in MELA quick®12+) Mains connection for IEC plug Connection for external waste water container Spring safety valve Slit for emergency unlocking Connection for external feed water container

 Open the catalog to page 5
MELAquick 12+-6

MELA  uick®12+ p q The stand-alone device. This innovative device concept can also be used if there is no compressed air connection in the preparation room. MELA quick®12+ p has a compressor pump integrated into the device, which permits operation of the autoclave irrespective of location. The functionality and short operating times are identical in both MELA quick®12+ devices. Documentation and approval. Possibilities for documentation, batch release and re-tracing known from the Pro- and PremiumClass MELAG device series are also available for the MELA quick®12+. Starting with MELA flash through...

 Open the catalog to page 6

Archived catalogs

  1. MELAseal Pro

    4  Pages

  2. Cliniklav®25

    12  Pages

  3. Vacuklav 40 B+

    12  Pages

  4. Cliniclave 45 M

    12  Pages

*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.