
Give routine a different taste Three models.Three targets. One high-quality standard
Open the catalog to page 1««• ZENTT'C5S"IC5'H-r I Three models.Three targets. One high-quality standard
Open the catalog to page 2Zenit G-Sight Systems: technology The screening for anti-nuclear antibodies (ANAs) performed on human epithelial (HEp-2) cells by indirect immunofluorescence (IIF) tests is the gold standard method in the diagnostic approach to systemic rheumatic disorders recommended by both the European and the American guidelines. The need for standardized and reproducible evaluation of cell-based IIF assays that overcome the disadvantages of classic assay have guided autoimmunity laboratories on the road to automation. The Zenit G-Sight systems from A. Menarini Diagnostics for image acquisition and interpretation...
Open the catalog to page 3««• ZENTT'C5S"IC5'H-r I Three models.Three targets. One high-quality standard
Open the catalog to page 4Zenit G-Sight Systems: characteristics Zenit G-Sight Twice: High performance, moderate cost, limited analytic autonomy Conceived as an entry-level instrument for its relatively low cost (30-35% less than Zenit G-Sight Classic), Zenit G-Sight Twice has the same performance of the other instruments but less autonomy for the analysis: the motorized scan stage holds 2 slides. In case of high workload, the operator simply needs to load the slides more frequently. Zenit G-Sight Classic*: Perfect for the daily routine with large sample numbers Zenit G-Sight Classic is the prototype among the Zenit G-Sight...
Open the catalog to page 5Three models. Three targets. One high-quality standard
Open the catalog to page 6Zenit G-Sight Systems: technical features and specifications Technical specifications Zenit G-Sight Twice Zenit G-Sight Classic Zenit G-Sight AMiDot Objectives Optional objectives Scan stage Scanning speed 4x, 40x Five remaining available positions for accommodating objectives (max. of 7) 20x for tissues Holds up to 2 IIF slides - 5-6 minutes for each well - About 1 minute for 5 images 4x, 40x Five remaining available positions for accommodating objectives (max. of 7) 20x for tissues Holds up to 8 IIF slides - 5-6 minutes for each well - About 1 minute for 5 images Illumination Type of compression...
Open the catalog to page 7Three models. Three targets. One high-quality standard AUSTRIA A. Menarini GmbH Pottendorfer Strasse 25-27 A-1120 Wien Tel. +43-1-8041576 Fax +43-1-8043194 BELGIUM A. Menarini Diagnostics Benelux S.A/N.V. Belgicastraat 4 1930 Zaventem, Belgium Tel. +32-2-7214545 Fax +32-2-7209292 FRANCE A. Menarini Diagnostics France S.A.R.L. 3-5, rue du Jura - BP 70511 94633 Rungis Cedex, France Tel. +33-1-56346910 Fax +33-1-56346911 GERMANY A. Menarini Diagnostics Deutschland Eine Division der Berlin Chemie AG Glienicker Weg 125 - 12489 Berlin Tel. +49-2-30-67073000 Fax +49-2-30-67073020 GREECE A. Menarini...
Open the catalog to page 82 Pages
2 Pages
4 Pages
8 Pages