Non-Invasive Transcutaneous Bilirubin Meter The BiliCare™ Transcutaneous Bilirubin Meter The BiliCare System measures the level of bilirubin using a patented technology that has been validated in clinical studies to provide accurate results. BiliCare technology is based on spectroscopy—measuring substances using light at varying wavelengths. The BiliCare System measures the level of transcutaneous bilirubin in the newborn by transmitting light at different wavelengths through the outer ear. The amount of light absorbed by the bilirubin is calculated by comparing the intensity of the light before it enters the tissue with its intensity after it leaves. Then the transcutaneous bilirubin of the newborn is calculated according to a customized algorithm. Non-Invasive Transcutaneous Bilirubin Meter • Less sensitive to motion artifacts • Not sensitive to differences in pressure applied or angle of device The LED advantage Unlike Xenon lamps that deteriorate over time and require calibration service every few years, LEDs do not deteriorate over time. No shift in power or in wavelength means no need for routine calibration. Optional calibration check allows user to confirm calibration when desired. The calibration check process is quick and easy & provides immediate results. Accurately and conveniently measures and monitors the level of bilirubin to assess the risk of neonatal hyperbilirubinemia. Perfect for use in the NICU, newborn nursery, mother’s room or pediatrician’s office. www.mennenmedical.com Israel: Mennen Medical Ltd. 6 Ha-Kishon Street, Yavne, P.O. Box 102, Rehovot 7610002, Israel. Phone: +972-8-9323333. Fax: +972-8-9328510 United States: Mennen Medical Corp. 290 Andrews Road, Feasterville-Trevose, PA 19053-3480, USA. Phone: +215 259-1020. Fax: +215 357-2010 United Kingdom: Charter Kontron Ltd. Unit 18 Avant Business Center 21 Denbigh Road Milton Keynes MK1 1DT, UK. Phone: +44 1908 646070. Fax: +44 1908 646030 Mennen Medical Ltd. All rights reserved. Data is subject to be changed wi
Open the catalog to page 1THE NEXT GENERATION TRANSCUTANEOUS BILIRUBIN METER: MEASUREMENTS IN A NON-INVASIVE DEVICE • Simple for the User & Gentle on the Baby Ease of Use — just follow the simple prompts for quick measurement where and when you need it - Reduces the need for or number of heel sticks by providing accurate measurements at the bedside - Only requires a single measurement per test Neonatal jaundice is a common condition, but when not carefully monitored, • LED Transmission Technology Reduces User Variances & Maintenance Requirements hyperbilirubinemia can lead to kernicterus, a devastating condition....
Open the catalog to page 2All Mennen Medical catalogs and technical brochures
-
Cerebraline
4 Pages
-
hepatic-xvu
2 Pages
-
BiliCare
2 Pages
-
DTR8
4 Pages
Archived catalogs
-
VL 4000
2 Pages
-
VL 6000
2 Pages
-
Patient monitors
2 Pages
-
Horizon XVu
2 Pages
-
HemoCIS plus
2 Pages