BiliCare
2Pages

{{requestButtons}}

Catalog excerpts

BiliCare - 1

Neonatal Noninvasive Bilirubin Meter The BiliCare™ Transcutaneous Bilirubin Meter The BiliCare System measures the level of bilirubin using a patented technology to provide accurate results. It’s technology is based on spectroscopy. The System measures the level of transcutaneous bilirubin in the newborn by transmitting light at different wavelengths through the outer ear. The amount of light absorbed by the bilirubin is calculated according to a customized algorithm. Neonatal Noninvasive Bilirubin Meter • Less sensitive to motion artifacts • Not sensitive to differences in pressure applied or angle of device The LED advantage LEDs do not deteriorate over time. No shift in power or in wavelength means no need for routine calibration. Optional calibration check allows user to confirm calibration when desired. The calibration check process is quick and easy & provides immediate results. Communication features Accurately and conveniently measures and monitors the level of bilirubin to assess the risk of neonatal hyperbilirubinemia. BiliCare includes communication features that may connect it to a PC and/or to a HIS via HL-7 BiliCare Viewer se in u r o f t c Perfe U or the NIC rsery rn nu newbo Unique S/W that displays the results in tables and graphs. These may be printed and exported. www.mennenmedical.com Israel: Mennen Medical Ltd. 4 Paran Street, Yavne, 8122503, Israel. Phone: +972-8-9323333. Fax: +972-8-9328510 United States: Mennen Medical LLC. 868 W. Street Rd. Unit #405, Warminster, PA 18974, USA. Phone: +215 259-1020. Fax: +215 357-2010 United Kingdom: Charter Kontron Ltd. Atlantic House 3 Michigan Drive Tongwell Milton Keynes MK15 8HQ UK Phone: +44 (0)1908 646070 Fax +44 (0)1908 646030 Gerium Medical Ltd. and it's Product BiliCare is ISO/CE ce

Open the catalog to page 1
BiliCare - 2

THE NEXT GENERATION TRANSCUTANEOUS BILIRUBIN METER MEASURING WITH BILICARE Simple for the User & Gentle on the Baby Neonatal jaundice is a common condition, but when not carefully monitored, • Reduces the need for Total Blood Bilirubin and the number of sticks in the baby’s heel, by providing an hyperbilirubinemia can lead to kernicterus, a devastating condition. Early measurement of bilirubin levels, leading to early intervention is recommended but the accurate bedside measurement time to take a blood sample and the trauma to the baby made universal screening difficult. • Only requires a...

Open the catalog to page 2

All Mennen Medical catalogs and technical brochures

  1. Cerebraline

    4 Pages

  2. hepatic-xvu

    2 Pages

  3. DTR8

    4 Pages

Archived catalogs

  1. VL 4000

    2 Pages

  2. VL 6000

    2 Pages

  3. BiliCare

    2 Pages

  4. Horizon XVu

    2 Pages

  5. HemoCIS plus

    2 Pages