Environmental Monitoring Product Guide
20Pages

{{requestButtons}}

Catalog excerpts

Environmental Monitoring Product Guide - 1

Environmental Monitoring Product Guide Sample Collection, Preparation, and Analysis for Air, Water, and Soil

Open the catalog to page 1
Environmental Monitoring Product Guide - 2

Environmental Monitoring Whether you need to collect large quantities of air to monitor particulate contamination, or analyze soil or water for hazardous chemicals, we can supply the expertise, products and protocols to ensure superior analytical results and compliance with regulatory requirements. Millipore devices and systems designed for environmental applications have been developed for use with standard methods, including those of NIOSH, OSHA™, and ASTM™. Alpha particle monitoring Industrial particulates Soil Monitoring Toxicity Characteristic Leaching Procedure (TCLP) Extraction Gas...

Open the catalog to page 2
Environmental Monitoring Product Guide - 3

Millipore supports you at every stage of the environmental monitoring workflow. Sample Collection Whether you need to collect large quantities of air to monitor particulate contamination, or analyze soil or water for hazardous chemicals, we can supply the expertise, products and protocols to ensure superior analytical results and compliance with regulatory requirements. • Sampling Kits • Filter Discs • Monitor Refills • Filter Holders • Solvent Dispensers Sample Preparation For the best downstream results, choose the best upstream tools. Sample preparation with Millipore filtration products...

Open the catalog to page 3
Environmental Monitoring Product Guide - 4

SPECIAL APPLICATION In order to reap the benefits of nuclear energy responsibly, both users and regulatory organizations must monitor the degree to which radioactive byproducts of human activity enter the environment. Human activities that generate radioactive particles include scientific experiments involving radiation, medical therapies, nuclear-powered submarines, x-ray procedures, nuclear power plants, and smoke detectors. The potential for misuse of radioactive materials and weapons by terrorist organizations and other criminals also demands vigilant radiation monitoring. Nuclear power...

Open the catalog to page 4
Environmental Monitoring Product Guide - 5

Collection is the first step of air, water and soil testing. An appropriate, representative sample is critical for accurate results. Millipore offers products for collecting diverse samples such as in-line purified water, liquid from cooling towers, air or other gases, and environmental field samples.

Open the catalog to page 5
Environmental Monitoring Product Guide - 6

Environmental Sample Collection Aerosol Filter Holders Vacuum-filter air or other gases from open atmospheres or from closed systems for particulate contamination analysis. Three-piece, 25 and 37 mm Aerosol Analysis Monitors Aerosol monitors contain 0.45 pm and 0.8 pm MCE membranes. Convenient matched weight monitors include two filters matched to within 0.1 mg. A cellulose support seal between monitor sections distributes sample evenly over the filter.

Open the catalog to page 6
Environmental Monitoring Product Guide - 7

1. Glass Fiber Filters Borosllicate microfiber glass without binder resin. Gravimetric stability up to 500 °C. For suspended solids in water and waste water. 2. Isopore™ Membrane Filters Polycarbonate film. Consistently low ash and tare weights. Hydrophilic, non-hygroscopic. For Chemotaxis, Environmental/air analysis. 3. PTFE Membranes Fluoropore Membrane Filters Bonded to high-density polyethylene support for easier handling. Broad chemical compatibility. For air monitoring, prefiiltration of solvents. Mitex’" Membrane Filters Unsupported PTFE membrane. It can be used under extreme...

Open the catalog to page 7
Environmental Monitoring Product Guide - 8

Sample Preparation Proper sample handling and preparation should begin immediately after collection to ensure accurate downstream analysis. Millipore’s family of certified sample preparation devices provide a disposable, yet reliable method for collecting and preparing environmental samples. For ultimate quality and convenience, use Millex® syringe filters. With their low extractables and low binding membranes, Millex filters are ideal for sensitive instrumental analysis, including gas, liquid and ion chromatography. A wide range of chemical compatibility enables their use with virtually...

Open the catalog to page 8
Environmental Monitoring Product Guide - 9

Millex Syringe Filters Filter Diameter (mm) Millex-LCR Filters for HPLC 4, 13, and 25 mm Millex-LCR filter units are low extractable filters specifically designed for HPLC. o HPLC Certified for low extractables o Low binding hydrophilic PTFE membrane o Filters both aqueous and organic solvents 13 mm size available with extended tube outlet for convenient filtration directly into autosampler vials or other small vessels.

Open the catalog to page 9
Environmental Monitoring Product Guide - 10

Millex Syringe Filters for Sample FiltrationMillex filters with Durapore membrane Description Millex filters with Nylon membrane Description HPF Millex Filters for High Particulate Filtration This dual membrane Millex filter is ideal for clarification of particulate-laden solutions prior to instrument analysis. The product includes two different media: a graduated glass fiber prefilter (10.0 to 0.7 pm) to remove larger particles and a 0.45 pm membrane filter for fine filtration. o Two to four times greater throughput than syringe filters without prefilters o Manual or automated use For a...

Open the catalog to page 10
Environmental Monitoring Product Guide - 11

To provide more informative environmental testing results, manufacturers of analytical instruments are constantly developing new technologies with lower and lower detection limits, demanding that samples be treated with the highest quality analysis tools. Millipore devices and systems designed for environmental monitoring analysis have been developed for use with standard methods, including those of NIOSH, OSHA, and ASTM. EXAMPLES OF REGULATED METHODS ARE: To get product recommendations on other methods, contact technical service at www.millipore.com/techservice.

Open the catalog to page 11
Environmental Monitoring Product Guide - 12

Hazardous Waste Filtration Systems For use in: o USEPA EP Toxicity Test (EPA Method 1310) for non-volatile or semi-volatile waste o Toxicity Characteristic Leaching Procedure (TCLP) applications (EPA Method 1311) - Separates solid and liquid phases of waste samples - Contains interior holder with PTFE coating to prevent heavy metal contamination - Allows easy introduction of bulky samples through wide entry port and removable top plate ZHE Hazardous Waste Filtration System Millipore's ZHE (Zero Head Space Extractor) system has been designated by the USEPA as a suitable apparatus for...

Open the catalog to page 12

All Merck catalogs and technical brochures

  1. SDS 500

    8 Pages

  2. ChromBook