Sterile Millex® Syringe Filters Overview

Millex® sterile syringe filters are designed for venting, gas filtration, and sterile filtration of biological and chemical solutions. They are autoclavable and suitable for sterile gas filtering, venting sterile containers, and in-line vacuum pump protection.

Membrane Types and Specifications

  • PTFE Fluoropore™ Membrane: Hydrophobic chemistry for gas filtration; pore sizes 0.20 µm and 0.45 µm; diameters 25 mm and 50 mm; polypropylene housing; various inlet/outlet connections including Luer and hose barb; CE marked.
  • PES Millipore Express® Plus Membrane: Fast flow, low binding for cell culture media; pore sizes 0.22 µm and 0.45 µm; diameters 25 mm, 33 mm, 50 mm; PVC or acrylic housing; sterilized by ethylene oxide or radiosterilization.
  • PVDF Durapore® Membrane: Lowest protein binding; pore sizes from 0.1 µm to 5.0 µm; diameters 4 mm to 33 mm; various housings; suitable for protein-rich solutions.
  • PVDF Durapel™ Membrane: Superhydrophobic for air venting and gas filtration; 0.22 µm pore size; PVC housing.
  • MCE MF-Millipore™ Membrane: General purpose membrane; pore sizes 0.22 µm, 0.45 µm, and 0.8 µm; PVC or acrylic housing.
  • Hydrophilic PTFE Membrane: Broad chemical compatibility; 0.2 µm pore size; HDPE housing.

Applications

  • Research: Sterile filtration of tissue culture media, buffers, DMSO, biological solutions.
  • Medical: CE marked and/or FDA registered filters for medical use, including fast flow, low binding membranes and superhydrophobic membranes for vial venting and transducer protection.

Non-Sterile Millex® Syringe Filters

Designed for chromatography (HPLC, IC, GC), general particle removal, industrial and environmental applications.

Membrane Types and Features

  • PTFE Hydrophilic Millipore® LCR Membrane: Lowest extractables, excellent solvent resistance; pore sizes 0.20 µm and 0.45 µm; diameters 4 mm to 33 mm.
  • PTFE Hydrophilic IC Millex® Filters: Low ion chromatography extractables; pore sizes 0.20 µm and 0.45 µm; diameters 13 mm and 25 mm.
  • PTFE Hydrophobic Fluoropore™ Membrane: Excellent solvent resistance; pore sizes 0.20 µm and 0.45 µm; diameters 4 mm to 33 mm.
  • PVDF Durapore® Membrane: Low protein binding; pore sizes 0.22 µm and 0.45 µm; diameters 4 mm to 33 mm.
  • Nylon Membrane: Broad chemical compatibility; pore sizes 0.20 µm and 0.45 µm; diameters 13 mm and 33 mm.
  • PES Millipore Express® Membrane: Fastest flow, high throughput; pore sizes 0.22 µm and 0.45 µm; diameters 13 mm and 33 mm.
  • MCE Membrane: General laboratory filtration of aqueous solutions; pore sizes 0.22 µm, 0.45 µm, and 0.8 µm; 25 mm diameter.

Automation Compatible Filters

Filters designed for dissolution testing and HPLC sample preparation with various membranes (PVDF, hydrophilic PTFE, Nylon) and glass fiber prefilters. Available in 25 mm diameter with pore sizes 0.20 µm, 0.22 µm, 0.45 µm, and 1.0 µm.

High Particulate Filtration & Automation Compatible

Filters with graduated multi-layer glass fiber prefilters for chromatography sample prep, wine analysis, and general particulate removal. Membranes include hydrophilic PTFE, PVDF, and Nylon, all 25 mm diameter with 0.20 µm or 0.45 µm pore sizes.

Samplicity® G2 Filtration System

A vacuum filtration system enabling simultaneous filtration of 1 to 8 samples directly into standard HPLC, UPLC, or GC sample vials (12 × 32 mm). It facilitates faster and easier use of Millex® 33 mm syringe filters for multiple samples.

Housing Materials

  • High-density polyethylene and polypropylene for chromatography, automation, and high-particulate filtration applications.
  • PVC housing used where noted.

Available Membranes for Samplicity® G2

  • Hydrophilic PTFE (0.20 µm and 0.45 µm)
  • PVDF Durapore® (0.22 µm and 0.45 µm)
  • Nylon (0.20 µm and 0.45 µm)
  • PES (0.22 µm and 0.45 µm)

Accessories

  • Samplicity® G2 System base
  • Vial trays
  • Waste trays
  • Tube set assembly
  • Replacement lids

Key Notes and Recommendations

  • Medical devices are sold only in countries where registered; contact local support for availability.
  • Filters are available in various pack sizes ranging from 10 to 1000 units depending on product type.
  • Membrane pore size and housing material selection depend on application requirements such as chemical compatibility, flow rate, and protein binding.
  • Autoclavable filters are suitable for sterile gas filtration and venting applications.
  • Hydrophobic membranes are preferred for gas and alcohol filtration; hydrophilic membranes for aqueous solutions.
  • Prefilters (glass fiber) enhance filtration of high particulate samples and are compatible with automation systems.

For more information, visit SigmaAldrich.com/OneMillex.

© 2023 Merck KGaA, Darmstadt, Germany. All rights reserved.

See more

Catalog excerpts

Sterile Millex® syringe filters you can trust.-1

Millipore. Preparation, Separation, Filtration & Monitoring Products Research Applications: Sterile filtration of tissue culture media and additives / Buffers / DMSO / Biological solutions Pore Size Diameter Process Volume (^m) (mm) (hold-up) Housing, Connections sterilization method (inletjoutlet) PES Millipore Express® Plus Membrane 0'22 Fast flow and low binding for cell culture media preparation HB | HB with filling bell SLGPB5010 PVDF Durapore® Membrane Lowest binding for protein rich solutions Vented FLL|MLS PVDF Durapel™ Membrane Superhydrophobic for air venting 0.22 and gas filtration Most referenced general purpose Hydrophilic PTFE Membrane Broad chemical compatibility PTFE Fluoropore™ Membrane alcohol filtration Medical Applications*: CE marked and/or FDA registered for medical intended use. *Medical devices are only sold in countries where they are registered. Please contact your local customer support team for availability. Autoclavable for sterile-filtering gases / Venting sterile containers / In-line vacuum pump protection Pore size Diameter Sterilization Inlet Outlet (pm) (mm) method connection connection 10 PK 25 PK PTFE Fluoropore™ Membrane Hydrophobic chemistry for gas filtration 0.20 pm 50 mm PP, Autoclavable HB (latex) 1/8 in. NPTM SLFG65010 See more on back side. PVC = Polyvinyl Chloride, PP = Polypropylene, EO = Ethylene Oxide, RS = Radiosterilized HDPE = High-density polyethylene FLL = Female Luer-Lok™ outlet, FLS = Female Luer slip, MLL = Male Luer-Lok™ outlet, MLS = Male Luer slip, HB = Stepped 1/2-1/4 in. Hose Barb NPTM = National Pipe Thread Male

 Open the catalog to page 1
Sterile Millex® syringe filters you can trust.-2

Non-Sterile Millex® syringe filters 4 you can trust. Chromatography HPLC, IC, GC / General particle removal / Industrial / Environmental Diameter (mm) Pore Size (Mm) Process Volume (hold-up) PTFE Hydrophilic Millipore® Lowest extractables and excellent solvent resistance PTFE Hydrophilic IC Millex® Low IC extractables/Ion Chromatography Certified 25 PTFE Hydrophobic Fluoropore™ Membrane 4 Excellent solvent resistance PVDF Durapore® Membrane Low-protein binding Nylon Membrane Broad chemical compatibility 13 Fastest flow, high throughput General laboratory filtration of aqueous solutions Automation...

 Open the catalog to page 2
*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.