LATITUD - 1

Acetabular Cup System & Uncemented Stems India Office Meril Health Care Pvt. Ltd. H1 - H3, Meril Park Survey No 135/2/B & 174/2 Muktanand Marg, Chala, Vapi-396191, Gujarat, India T : +91 260 3052 100 E : info@maxxmed.com India Sales Office Maxx Medical Pvt. Ltd. 512-513, Midas Sahar Plaza Complex J.B. Nagar Andheri (East) Mumbai 400 059 T : +91-22-40479797/ 32170808 F : +91-22-40479717 E : info@maxxmed.com United States Maxx Orthopedics, Inc. 531 Plymouth Road Suite 526 Plymouth Meeting, PA 19462 T : +1-484-342-0092 x 2100 F : +1-484-342-0096 E : info@maxxortho.com

Open the catalog to page 1
LATITUD - 2

Endo-Surgery Orthopedics Meril is a global medical device company dedicated towards design and development of novel, clinically relevant, state-of-the-art and best-in-class devices to alleviate human suffering and improve the quality of life, spanning broad operational canvas from vascular interventional devices to orthopedics, in-vitro diagnostics and endo-surgery. Meril Orthopedics | HIP SYSTEM We share an enduring commitment to advance healthcare solutions, so more patients live longer, healthier lives. We thus have a strong commitment towards R&D and adherence to best quality standards...

Open the catalog to page 2
LATITUD - 3

Acetabular Cup System Acetabular cup system is a modular acetabular replacement system consisting of a range of Titanium coated modular shells designed for use with highly cross-linked polyethylene liners articulating with a range of dedicated cobalt chromium alloy modular heads. Enhance the Press Fit The design geometry of the shell allows press t to occur just below the acetabular bone margin to assist retention and stability. Hip Compatibility Table SHELL SIZES LINER SIZE

Open the catalog to page 3
LATITUD - 4

Uncemented Stems The design philosophy for Cement less femoral stem of latitudTM total hip replacement system is adopted from well proven and successful corail stem design. Cement less femoral stem is provided in two different angles to meet with patient's anatomy and developed into two versions: standard and increased offsets. The surface of cement less femoral stem is coated with hydroxyapatite with plasma spraying method for osteo-integration purpose and to be used without cement. The Dual Taper Trapezoidal Design with vertical and horizontal grooves to promote stability and resist...

Open the catalog to page 4
LATITUD - 5

With the correct rasp in placeremove the rasp handle and if required trim the neck using the calcar cutter fitted onto th T-handle. If the fit os this first rasp is unstable then the next size of intramedullary reamer is used follwed by the corresponding size rasp. This ream/rasp technique is continued until the fit of the rasp is stable. With the rasp still place, the fin cutter is gently tapped home into the groove int he rasp with the teeth facing the greater trochanter. The proximal femur is opened using the box chisel which is positioned laterally and posteriorly so that entry is in...

Open the catalog to page 5
LATITUD - 6

Instrument Set 1. Accetabulum Cup System 2. Uncememted Stem

Open the catalog to page 6