Catalog excerpts
Technical specifications: Measurement range: Linearity: Resolution: Response time T10 - T90: Zero stability: Initial heating time: Atmospheric pressureinfluence: N2O compensation: Calibration: Power supply: Graphic display: Output: • analogue • serial Dimensions: Weight: Additional advantages: • real time clock • memory 256 kB (12 input) • software transmission program to any PC with Pet CO2 and Pe CO2 analysis • trends displaying • analogue output PeCO2 and PetCO2 signaling • ability to connect with a thermal printer • setting alarm systems for exceeding range of average and ending exhaust values Alarms: • exceeding of programmed breath frequency signalization program • exceeding of programmed CO2 concentration range signalization system Capnograph CO2 TEST 2000 IR is designed for continuous non-invasive monitoring of CO2 capacity in air exhaled by a person. The device analyses the sample in the side stream, taken from the main exhalation track. Sucked-up by an analyzer air is transferred through a dryer device to the quick analyzer, operating on a infrared absorption method. The analyzer operates „breath-by-breath” method and gives the following carbon dioxide concentration values: final exhalation and average for whole exhalation. Pulsoximeters and capnographs production of MES pulsoximeters is based on measuring systems and sensors delivered under the contract with an American company NONIN Medical Inc. The devices are designed for the non-invasive measurement of hemoglobine SpO2 oxidation extent and HR pulse frequency. The sensors operate using the light absorption effect by flowing blood trough the blood vessels. For measurement purposes has been used the 650 nm wavelength in a range of visible light and wavelength of 910 nm in infrared. Depending on a user purposes and requirements, MES Inc. offers four models of pulsoximeters differing in the way of: results visualization, dimensions, power supply system, results storing range, compatibility with other devices and signaling system range of exceeding preset parameters as well. MES Inc. produces capnograph CO2 TEST 2000 IR designed for continuous, non-invasive monitoring of changes in carbon dioxide capacity in air exhaled by a person.
Open the catalog to page 1Pulsoximeter OXY TEST 250 is designed for continuous monitoring of SpO2 signal and pulse frequency changes in real time. The device consists a large graphical LCD display which enables even remote reading of test results. All functions are accessible by using two buttons only, which makes the device exceptionally easy to use. Pulsoximeter OXY-TEST 250 has a tight waterproof casing. A large clip on the back of the case allows for attaching to a bed or a patient clothing.Optionally pulsoximeter OXY-TEST 250 can be equipped with OXY-TEST 2000M software for on line transmission to any PC...
Open the catalog to page 2All MES catalogs and technical brochures
-
VO2maxTracker
6 Pages
-
Lungtest LAB Body
4 Pages
-
Lungtest Basic
4 Pages
-
Lungtest LAB
6 Pages
-
Lungtest Handy
2 Pages
-
Lungtest Mobile
2 Pages
-
VO2max Finder
6 Pages
-
h/p cosmos quasar
1 Pages
-
ERGOSPIROMETER VO2max Finder
4 Pages
-
START 2000/START 2000M
4 Pages
-
Rhinotest 500
2 Pages
-
Lungtest 1000
4 Pages
-
Lungtest 250
2 Pages
-
Lungtest Handy
2 Pages
-
Spirometr Lungtest Mobile
2 Pages