Catalog excerpts
Rhinomanometers Rhinotest 500 and Rhinotest 1000 are electronic devices for examinations of flow and pressure in patient nasal ways. Measurements provided by those devices, use an active anterior and posterior rhinomanometry method. Resistance values are determined by the standard and the Broms method. Innovative technical solutions used by MES in both Rhinotest 500 and Rhinotest 1000, affords possibilities to provide rhinospirometry in a forced nasal flow and maximally ventilation per minute. Rhinotest 1000 is a stationary, electronic medical device, consisting precise measurement unit operated by any PC computer with software implemented in any version of MS Windows based system. Basic advantages of Rhinotest 1000: q up-to-date pneumotachograph heads q immediate ability to operate after head replacing q data base with ability to provide epidemiological researches q software makes possible results transmission to statistical programs q connected computer can operate independently Rhinotest 500 is a small, portable electronic medical device, consisting precise measurement unit and internal computer for taking measurements and evaluating test results. Basic advantages of Rhinotest 500: q up-to-date pneumotachograph heads q immediate ability to operate q q q q q q q q after head replacing ability to data transmission to any PC compatible with MS Windows based system full keyboard for patient data and examination results description input high resolution graphical LCD display for graphs and chart of results viewing data base with capacity 100 tests ability to connect computer or thermal printer ability to input and storage your own institution letterhead (3 lines for 40 characters) ability to enter and storage your comments of the test taken small dimension and small weight
Open the catalog to page 1TECHNICAL SPECIFICATION: Flow range. ± 18 l/s Flow measurement accuracy <2% Usable flow resolution ± 10 ml/s Pressure range ± 1,25 kPa Pressure measurement accuracy ±1% Pressure measurement resolution ± 1 Pa Dimensions 334x240x40 mm Weight (without printer) Power supply MESUREMENT HEADPIECE Deadspace DV 40 Head DV 40 resistance PATIENT DATA: First name, last name, date of birth, body weigh, height, sex, test identification number, Identification number of patient, physician name. STANDARD EXAMINATIONS: Anterior method by Broms and by standard: RnRSln, RnRBln, RnRSEx, RnRBEx, RnLSln, RnLBln,...
Open the catalog to page 2All MES catalogs and technical brochures
-
VO2maxTracker
6 Pages
-
Lungtest LAB Body
4 Pages
-
Lungtest Basic
4 Pages
-
Lungtest LAB
6 Pages
-
Lungtest Handy
2 Pages
-
Lungtest Mobile
2 Pages
-
VO2max Finder
6 Pages
-
h/p cosmos quasar
1 Pages
-
OXY-TEST 2000M
2 Pages
-
ERGOSPIROMETER VO2max Finder
4 Pages
-
START 2000/START 2000M
4 Pages
-
Lungtest 1000
4 Pages
-
Lungtest 250
2 Pages
-
Lungtest Handy
2 Pages
-
Spirometr Lungtest Mobile
2 Pages