ME750 - 1

ME75x/MEP75x datasheet MONOLITHIC PIEZORESISTIVE CERAMIC PRESSURE TRANSDUCER Metallux ME75x and MEP75x are monolithic pressure sensors made with ceramic cell and work following the piezoresistive principle. The Wheatstone bridge is screen printed directly on one side of the ceramic diaphragm by means of Thick-Film technology and signal conditioning electronics are added to generate 0.5...4.5 V ratiometric output (ME750), current loop 4...20 mA (ME751) or 0...10 V non ratiometric output (ME752). Also available in customized version I2C output. Pressure and temperature calibration are done electronically with the on-board ASIC and can be performed in bar (ME75x) or in psi (MEP75x). Electronics provide offset and span correction when temperature changes. Aging detection is constantly performed. This new method guarantees good precision and long-term stability. The Metallux ME75x family meets EMC requirements. The ASIC stores production lot specific data for sensor traceability and allows custom calibration. Due to the excellent chemical immunity of the the Al2O3 ceramic, the ME75x sensors are suitable for nearly all aggressive media. FEATURES Excellent resistance to corrosion and abrasion Signal conditioning EMC compliant Thermally compensated Zero stress mounting software Pressure sensors family tree ME600 (P+T) Measuring cell Piezore sistive Gau ge Al 2O3 96% Sign al Conditione d Ø18 mm Piezore sistive Gau ge sealed gau ge absolu te Sign al Conditione d Ø9 mm. With housing Capacitve Gau ge sealed gau ge absolu te Measuring cell METALLUX - Via Moree 12 - 6850 Mendrisio – Switzerland Metallux SA reserves the right to change this datasheet without notice Also available in not thermally compensated version Digitally trimmed offset, also available not thermally compensated 3 Not available with sapphire diaphragm. 4 Suitable for low pressure range (≤1 bar) 2 Flush diaphragm Thermally compensated Measuring cell Ratiometri c Curren t loop METALLUX Pressure sensors

Open the catalog to page 1
ME750 - 2

ME75x/MEP75x datasheet Technical characteristics Parameters Output Output range Sensor type Technology Material Weight g Response time ms Supply voltage VDC Max current 1 mA Operating temp. °C Storage temp. °C Compliant with EMC / ESD compliance 2 Burst pressure Vacuum capability Current loop Non ratiometric 4...20 [mA] 0...10 [V] Monolithic, gauge Piezoresistive with electronic signal conditioning Ceramic Al2O3 96% ≤ 8 (with standard wires) ≤5 4.5...5.5 9...35 12...35 6 (RLOAD ≥ 2 kΩ) 4...20 8 (RLOAD ≥ 2 kΩ) -25...+125 (-13 °F...+257 °F ) -40...+135 (-40 °F...+275 °F ) REACH, RoHS,...

Open the catalog to page 2
ME750 - 3

ME75x/MEP75x datasheet Mechanical drawings Top View Side View Bottom View Retaining area is the same for all ME(P)75x versions For internal sealing please refer to our mounting proposal All quotes are in mm [inch] – General tolerance ISO 2768-1 M Electrical terminations ME750 Example: type 0, Connector plus 52 mm cable Wire section : AWG 28 Cable length: L = 52.0 ± 2 [ 2 ± 0.08 ] Stripping length: S = 3.2 ± 0.7 [ 0.13 ± 0.028 ] Vout*: Analog output (white) Operating temperature: -25°C...+125°C Connector on PCB : FCI 10114828-10203LF VCC : Power supply (red) *programming through Vout wire...

Open the catalog to page 3
ME750 - 4

ME75x/MEP75x datasheet Ordering code ME Output signal Ratiometric Current loop Non ratiometric Pressure range ME MEP 0...1.6 bar or 0...20 psi 0...2 bar or 0...30 psi 0...2.5 bar or 0...50 psi 0...4 bar or 0...60 psi 0...5 bar or 0...100 psi 0...6 bar or 0...115 psi 0...10 bar or 0...150 psi 0...16 bar or 0...300 psi 0...20 bar or 0...400 psi 0...25 bar or 0...500 psi 0...40 bar or 0...750 psi 0...50 bar or 0...1000 psi 0...100 bar or 0...1500 psi 0...200 bar or 0...3000 psi 0...250 bar or 0...4000 psi 0...400 bar or 0...5000 psi Others on request (please specify) Calibration High accuracy...