
Catalog excerpts

Hygiene Plan WHAT Object Hand dIsinfection WHEN Time/interval WITH of work WHAT Means (e.g. disinfectant) of hygienic measures Hygienic hand desinfection: • before work area preparation • after work area maintainance • before putting on and off gloves • before and after non-surgical treatment • after toilet use Hand disinfectant HOW cleaning Type of maintenance, and disinfection Disinfection by rubbing: Keep hands moist for 30 seconds with a sufficient amount of hand disinfectant. Responsible or concerned person Disinfection by rubbing: Keep hands moist for 3 minutes with a sufficient amount of hand disinfectant. Surgical hand disinfection: • before surgical interventions Hand washing • before start of work • after end of work • in case of visible contamination • after toilet use Cleaning and reduction of germs through washing Disinfection by spraying and wiping (wipe disinfection is preferred): Action time: 1 minute RESPONSIBLE PERSON: Disinfection by wiping: 1 minute action time RESPONSIBLE PERSON: Disinfection by wiping: 1 minute action time Cleaning and disinfection by spraying (foam) and wiping: 1 minute action time Disinfection by wiping: 1 minute action time Nurturing hand wash lotion with antimicrobial action Nurturing hand wash lotion Hand care after every treatment which have been contaminated but cannot be thermally disinfected or immersed in solutions (e.g. floating tables, storage systems) Spray disinfectant Small surfaces (e.g. outer surface of transmission instruments) after every treatment Large surfaces insensitive to alcohol (e.g. glass surfaces, metal) after every treatment Surfaces and objects sensitive to alcohols (e.g. dental chair coverings, acrylic or plexiglass) after every treatment Large surfaces of medical devices sensitive to alcohol (e.g. chair coverings) after every treatment Suction system, spittoon bowl Rinse with cold water after every treatment! Disinfection of suction system should be carried out once a day (at the end of the working day). The suction system must be disinfected before every invasive surgical treatment. everday before the first treatment, and as needed Hand and angle pieces, turbines Impression materials, prosthetic work Surgery stamp, Date, Signature: Alcohol-free cleaning and disinfecting foam Alcohol-free wipes immediately after removal from the patient immediately after use of the medical device Disinfection and cleaning by wiping Material-friendly surface disinfectant and cleaner Recommendation for use: 1% solution: 30 minutes action time Rinsing through suction of an air/water mixture Cleaning and disinfection through suction of a water, disinfectant and cleaner mixture (600 ml): 1% solution: 60 minutes action time RESPONSIBLE PERSON: RESPONSIBLE PERSON: Physical and chemical cleaning Disinfection spray spray water and coolant lines (medical devices) and auxiliary appliances used for treatments need to be classified into different risk groups: • non-critical medical devices (contact only with intact skin) • semi-critical medical devices (contact only with mucous membranes or pathologically affected skin) • critical medical devices (permeation of the skin or mucous membrane, contact with blood or inner tissues) Alcoholic wipes Alcoholic wipes in examination and treatment rooms SPECIAL AREAS with alcohol without alcohol Nourishing hand cream Spray disinfection Duration of spraying: 2 seconds Action time: 2 minutes Does not replace oil spray recommended by manufacturer! All materials must be immersed in the solution for 5 minutes. Then rinse thoroughly with water. Cleaning and disinfection by air bubble-free immersion of the instruments into the disinfection solution RESPONSIBLE PERSON: Instrument cleaning and disinfection RESPONSIBLE PERSON: Recommendations for use: 1% solution: 60 minutes action time Instrument reprocessing (manual/automated) 1. Preparation: Remove coarse contaminants using tissue paper. Air bubble-free immersion of instruments into the solution 2. Cleaning 3. Disinfection 4. Rinsing and drying 5. Further reprocessing according to risk group classification (sterilisation, if required) Note: • Use cold water to prepare the disinfection solution. • Observe the specifications of the instrument manufacturer. • After cleaning and disinfection, check whether the instruments are in a clean and intact condition. according to waste generation Note recycling possibilities hazardous waste (e.g. filters, lead foils, needles and scalpels, knives, amalgam capsules, extracted teeth, old pharmaceuticals) according to waste generation Disposal/recycling through Dental ECO Service Tel. no.: +43-512-205420 amalgam collection container • METASYS • Dürr • Sirona Disposal/recycling through Dental ECO Service Tel. no.: +43-512-205420 RESPONSIBLE PERSON: Storage and transport in specially approved containers according to EU-standards Replacement of the amalgam collection container and disposal according to manufacturer's specifications household-like waste METASYS ... makes the difference! www.metasys.com METASYS Medizintechnik GmbH Florianistraße 3, A-6063 Rum bei Innsbruck Phone: +43 512 205420 - Fax: +43 512 205420 7 G&C Hygiene Plan GB 11.2012 70010323 ZK-55.205/02 Subject to printing and setting errors! Please follow the manufacturer's instructions!
Open the catalog to page 1All METASYS Medizintechnik catalogs and technical brochures
-
GREEN&CLEAN 2023
20 Pages
-
Hygiene of the Dental Unit
8 Pages
-
COMPRESSORS
8 Pages
-
META Tower
4 Pages
-
Central Suction Systems
8 Pages
-
HYGIENE OF THEDENTAL UNIT
8 Pages
-
SPARE PARTS LIST
5 Pages
-
AMALGAM SEPARATION
8 Pages
-
METASYS GREEN&CLEAN
8 Pages
Archived catalogs
-
Amalgam Separator
6 Pages
-
Hand Disinfection
1 Pages
-
AMALGAM SEPARATION
6 Pages
-
Amalgam separators1
6 Pages