1. Catalogs
  2. Metrex
  3. CaviWipes 2.0 Technical Bulletin
video corpo

CaviWipes 2.0 Technical Bulletin

CaviWipes 2.0 Technical Bulletin

CaviWipes 2.0 Technical Bulletin

Product catalog summary
Product Description
CaviWipes 2.0 is a multi-purpose disinfectant designed for cleaning and disinfecting hard, non-porous surfaces and non-critical instruments in healthcare settings. It is particularly useful in environments where controlling cross-contamination is crucial.

Active Ingredients
  • Isopropyl Alcohol: 17.20%
  • Didecyl dimethyl ammonium chloride: 0.17%
  • Alkyl dimethyl benzyl ammonium chloride: 0.11%
  • Other Ingredients: 82.52%

Efficacy
Tuberculocidal Efficacy
  • Effective against Mycobacterium tuberculosis var: bovis (BCG) with a 2-minute contact time using the AOAC Tuberculocidal Activity Test.
Bactericidal Efficacy
  • Effective against various bacteria including Staphylococcus aureus, Pseudomonas aeruginosa, and Salmonella enterica with a 2-minute contact time using the Germicidal Spray Products as Disinfectants AOAC Method.
  • Effective against multi-drug resistant bacteria such as MRSA and VRE.
Virucidal Efficacy
  • Effective against non-enveloped viruses like Adenovirus Type 2 and Norovirus, and enveloped viruses such as Influenza A and B, with a 2-minute contact time using ASTM E1053-11.
Fungicidal Efficacy
  • Effective against Candida Auris with a 2-minute contact time using the OECD Quantitative Method.

Safety and Toxicity
  • No chronic hazards or carcinogenic components identified.
  • Classified as a Flammable Liquid Category 4 under GHS/HAZCOM 2012.
  • Minimal eye irritation and slight skin irritation observed.
  • Not a skin sensitizer.
See more

Catalog excerpts

CaviWipes 2.0 Technical Bulletin-2

Product Description CaviWipes 2.0 is a multi-purpose disinfectant for use in cleaning, and disinfecting hard non-porus, inanimate surfaces and non-critical instruments in hospitals, laboratories, and other critical care areas where environmental control of cross-contamination between treated surfaces is important.

 Open the catalog to page 2
CaviWipes 2.0 Technical Bulletin-3

Bactericidal Efficacy Studies Bacteria Staphylococcus aureus [ATCC 6538] Pseudomonas aeruginosa[ATCC 15442] Salmonella enterica [ATCC 10708] Legionella pneumophila [ATCC 33153] Bordetella pertussis [ATCC 12743] Moraxella catarrhalis [ATCC 25240] Enterococcus faecium [ATCC 51559] Klebsiella pneumoniae [ATCC 4352] Acinetobacter baumannii [ATCC 19606] Escherichia coli O157:H7 [ATCC 35150] Micrococcus luteus [ATCC 14408] Streptococcus mutans [ATCC 25175] Burkholderia cepacia [ATCC 25416] Stenotrophomonas maltophilia [ATCC 25596] Streptococcus pyogenes [ATCC 12344] Contact time tested Test Method...

 Open the catalog to page 3
CaviWipes 2.0 Technical Bulletin-4

Virucidal Efficacy Studies Non-Enveloped Viruses * Adenovirus Type 2* [ATCC VR-846] Norovirus – Feline Calicivirus as surrogate* [ATCC VR-782] Feline Calicivirus* [ATCC VR-782] Human Rotavirus* [ATCC VR-2018] Enterovirus Type 71* [ATCC VR-1432] Echovirus Type11* [ATCC VR-41] Contact time tested Test Method 2 Minutes ASTM E1053-11 “Standard Test Method to Assess Virucidal Activity of Chemicals Intended for Disinfection of Inanimate, Nonporous Environmental Surfaces” 5% Organic Soil Load PASS Organic soil load Test Results Enveloped Viruses* Herpes simplex virus Type 1* [ATCC VR-733] Herpes simplex...

 Open the catalog to page 4
CaviWipes 2.0 Technical Bulletin-5

Toxicity Study Test Guideline Test Results Minimal irritation to eyes. Acute Skin Irritation Slight skin irritation. Acute Inhalation Acute Dermal Toxicity Acute Oral Toxicity Skin Sensitization Chronic Hazards: None expected. Carcinogen: None of the components are listed as a carcinogen or potential carcinogen by IARC, NTP, ACGIH, or OSHA. GHS / HAZCOM 2012 Classification: Flammable Liquid Category 4 *Virus MKT-20-0687 ©2020 Metrex Research, LLC

 Open the catalog to page 5
*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.