Product catalog summary
Technical Specifications:
The document details the specifications for the 916 Ti-Touch, 915 KF Ti-Touch, and 917 Coulometer. Key features include intelligent dosing elements, touch control operation, and various stirrer options. These devices support multiple titration modes, offer FDA compliance, USB connectivity, and can generate PDF reports without a PC.
916 Ti-Touch:
This compact titrator is designed for potentiometric titration, supporting modes such as DET, MET, SET, STAT, and MAT. It features direct Intranet and LIMS access, plug-and-play operation, and a personalized touchscreen for quick method access. It ensures user safety with contact-free reagent replacement and offers paperless PDF reporting.
915 KF Ti-Touch:
Designed for volumetric Karl Fischer titration, this model integrates the buret, stirrer, and operating module into a compact unit. It includes features like KF icons for process tracking, a 'Safety Stop' to prevent overflow, and an integrated pump for safe reagent handling. The device supports automation and network connectivity for data management.
917 Coulometer:
This model is tailored for coulometric Karl Fischer titration, combining the operating module, stirrer, and pump in a compact design. It offers automation options, reagent monitoring, and paperless PDF reporting. The device features an integrated pump for convenient reagent handling and automatic titration start.
Network Integration and Data Management:
The Ti-Touch family supports network integration, allowing for PDF report export to LIMS or tiBase, and data archiving. The tiBase software facilitates data management, offering features like audit trails, traceability, and customizable reporting.
Automation with 810 Sample Processor:
The 810 Sample Processor enhances automation, allowing unattended analysis of up to 24 samples. It ensures precise and reproducible results, minimizes exposure to hazardous liquids, and offers flexibility with various sample racks.
Ordering Information:
The document provides ordering details for various models and optional accessories, including all-inclusive packages for specific titration applications and additional components like Dosino and Dosimat units.
See more

Catalog excerpts

916 Ti-Touch, 915 KF Ti-Touch and 917 Coulometer-1

916 Ti-Touch, 915 KF Ti-Touch and 917 Coulometer Compact titrator for routine analysis

 Open the catalog to page 1
916 Ti-Touch, 915 KF Ti-Touch and 917 Coulometer-2

916 Ti-Touch with Rod stirrer 916 Ti-Touch with magnetic stirrer Dosing element with Intelligent Exchange Unit/Dosing Unit with an integrated data chip Dosing steps per cylinder content 800 Dosino: 10,000 pulses; 805 Dosimat: 20,000 pulses Operation, dialog Stirrers, titration stand Touch Control Incl. 802 Rod stirrer additionally 1 × 801 Magnetic stirrer or 1 × 802 Rod stirrer or 1 × 803 KF Titration Stand Attachment of Dosimats, Dosinos, stirrers Built-in magnetic stirrer, additionally 1 x 801 Magnetic stirrer or 1 x 802 Rod stirrer or 1 x 803 KF Titration Stand 2 MSB connectors (Metrohm Serial...

 Open the catalog to page 2
916 Ti-Touch, 915 KF Ti-Touch and 917 Coulometer-3

Ti-Touch – the modern way to titrate «Reduce to the max» – this is the Ti-Touch concept. The compact titrator from Metrohm offers maximum performance in routine analysis in the smallest possible space: • Maximum system integration: buret, stirrer and control module in one practical unit. • Maximum data security and network integration – without a PC! - FDA Compliance: All Ti-Touch models comply with FDA-regulation 21 CFR, Part 11. - enerate forge-proof reports in PDF format and save them to a USB flash drive or to the G network. - thernet interface for direct access to the Intranet. Method Printing...

 Open the catalog to page 3
916 Ti-Touch, 915 KF Ti-Touch and 917 Coulometer-4

916 Ti-Touch – the compact titrator for potentiometric titration 04 The 916 Ti-Touch is the compact titrator ­ esigned d for potentiometric titration. The instrument supports all titration modes: DET (dynamic equivalence point titration), MET (monotonic equivalence ­ point titration), SET (titration to one or two specified endpoints), STAT (enzymatic and pH-STAT titrations), and MAT (manual ­ itration). t • Save and print data, etc. – without a PC USB interface for printer, keyboard or barcode reader. Save methods and determination data directly to a USB flash drive for uploading again at a later...

 Open the catalog to page 4
916 Ti-Touch, 915 KF Ti-Touch and 917 Coulometer-5

05 • Contact-free reagent replacement No contact with reagents thanks to the patented 800 Dosino technology. • Intelligent rod stirrer The stirrer rotational speed adapts automatically. • Incorrect results excluded All system components (electrodes, exchange units, etc.) and measurement results are monitored and malfunctions area displayed – in plain text. • iBase titration database for perfect workflow t Store determination data on a USB flash drive or in your network for direct importing from there into tiBase. • Paperless PDF reports Generate forge-proof PDF reports without a PC and save them...

 Open the catalog to page 5
916 Ti-Touch, 915 KF Ti-Touch and 917 Coulometer-6

915 KF Ti-Touch – the titrator for volumetric Karl Fischer titration 06 Just as with the 916 Ti-Touch, the 915 KF Ti-Touch Karl Fischer version is also an outstanding instrument: buret, stirrer and operating module are integrated in a single, compact system unit. This is not only practical but also and in particular saves a great deal of space on the laboratory table. • Affordable automation The 810 Sample Processor enables fully automated analysis for up to 24 samples. • Paperless PDF reports Generate forge-proof PDF reports without a PC and save them to a USB flash drive or to the network....

 Open the catalog to page 6
916 Ti-Touch, 915 KF Ti-Touch and 917 Coulometer-7

07 • Contact-free reagent replacement Contact with KF reagents is avoided with the patented Dosino technology. The moment of replacement is freely selectable. • Keeping track thanks to KF icons KF icons show whether the instrument is still conditioning or if water determination can now be started. • tiBase titration database for perfect workflow Store determination data on a USB flash drive or in your network for direct importing from there into t ­ iBase. • «Safety Stop» prevents the cell from overflowing The electrode test and the «Safety Stop» parameter prevent cell overflow during conditioning....

 Open the catalog to page 7
916 Ti-Touch, 915 KF Ti-Touch and 917 Coulometer-8

917 Coulometer – the compact titrator for coulometry 08 The 917 Coulometer is the compact titrator for coulometric Karl Fischer titration. The operating module, stirrer, and pump for reagent exchange are combined into a single, space-saving, compact instrument. • Automation is always an option Measurements can be easily automated with the 885 Compact Oven Sample Changer. • Paperless PDF reports Generate forge-proof PDF reports without a PC and save them to a USB flash drive or to the network. • Personalized touchscreen for fast method start Up to 14 methods per user can each be linked to a favorites...

 Open the catalog to page 8
916 Ti-Touch, 915 KF Ti-Touch and 917 Coulometer-9

• Integrated pump for optimum convenience The integrated pump enables the titration cell to be emptied and then refilled with fresh reagent at the touch of a button. Contact with reagents is completely avoided. • Keeping track with KF icons KF icons show whether the instrument is still conditioning or if water content determination can now be started. • Automatic titration start No manual titration start required. The instrument automatically begins the titration after the sample has been added. • tiBase titration database for maximum convenience Save determination data to a USB flash drive or...

 Open the catalog to page 9
916 Ti-Touch, 915 KF Ti-Touch and 917 Coulometer-10

All members of the Ti-Touch family now fully comply with FDA-regulation 21 CFR, Part 11. This includes: • Sophisticated user administration Allocate access rights to each user in accordance with your company’s security policy. • Complete Audit Trail Each action performed on a Ti-Touch Titrator is stored automatically in the Audit Trail. This means that you can obtain a detailed record of which employee performed what action at what point in time. • Complete traceability Who carried out a determination and when? What titrator was used? What alterations were made to the determination and by whom?...

 Open the catalog to page 10
916 Ti-Touch, 915 KF Ti-Touch and 917 Coulometer-11

tiBase – modern titration data management 11 Manage and archive your titration data Either your Ti-Touch is directly connected to your network or titration data is manually imported from a USB stick: Your determinations are therefore safely archived, giving you full traceability of all aspects of the determinations. This software will greatly facilitate your work, because you can search for and filter determinations. Straightforward reprocessing This is particularly helpful if you wish to correct the sample weight or use a different formula to calculate results, for example. It goes without saying...

 Open the catalog to page 11
*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.