1. Catalogs
  2. Metrohm
  3. NIRS XDS MasterLab Analyzer
video corpo

NIRS XDS MasterLab Analyzer

NIRS XDS MasterLab Analyzer

NIRS XDS MasterLab Analyzer

Product catalog summary
Features and Benefits
  • XDS NIR technology ensures ease-of-use and seamless method transferability.
  • Automated analysis of tablets or vials, with user-selected sizes.
  • Capable of analyzing fine powders to coarse granular materials.
  • Integrated variable spot-size for optimal sample illumination.
  • Hot-swappable modules allow quick changes without performance loss.
Analyzer Overview

The NIRS XDS MasterLab Analyzer utilizes XDS near-infrared (NIR) technology for rapid, non-destructive measurements of tablets, solids, and liquids. It replaces routine tests, reduces product hold time, and minimizes quarantine time. The analyzer supports unattended spectral acquisition, freeing operators for other tasks.

Specifications
  • XDS Laboratory Monochromator: Ensures precise instrument matching and seamless calibration transfer. Spectral coverage: 400-2,500 nm for reflectance, 850-1,600 nm for transmission.
  • XDS MasterLab Module: Automated transmission and reflectance analysis with integrated variable spot size.
  • XDS RCM Iris: Ensures reproducible sample positioning.
  • XDS Accessory Kit: Includes power cords, network cable, filters, replacement lamp, and documentation.
Software
  • Vision® SC/SP: Single-user software for chemical/pharmaceutical analysis, 21 CFR Part 11 compliant.
  • Vision® MC/MP: Multi-user software with centralized database management, 21 CFR Part 11 compliant.
Standards
  • Transmission: NIRStandardsTM Certified Tablet Transmission Standards.
  • Reflectance: NIRStandardsTM Certified Reflectance Standards, available in sets of 2 or 7.
Accessories and Options
  • Liquid Sampling Kit: For analyzing liquids with various optical pathlengths.
  • Sample Cups: For reflectance analysis of fine powders.
  • Spare Parts Kit: Includes lamps, fan filters, and fuses.
  • Validation Documentation: Electronic set for Vision SP/MP software validation.
  • Instrument Performance Certification: Semi-annual on-site certification by a certified engineer.
  • Training: Includes method development and service training courses.
Ordering Information
  • Analyzer: 2.921.1310 NIRS XDS MasterLab Analyzer.
  • Software: Various Vision software options, including FDA compliant versions.
  • Standards: NIRS Certified Reflectance Standards available in different sets.
See more

Catalog excerpts

NIRS XDS MasterLab Analyzer-1

NIRS XDS MasterLab Analyzer Features and Benefits • XDS NIR technology ensures ease-of-use and seamless method transferability • Automated transmission or reflectance analysis of a tray of tablets or vials (size of tablets or vials selected by user) • Analysis of fine powders to coarse granular materials such as pellets or flakes and dosage forms • Integrated variable spot-size for optimal sample illumination • Hot-swappable modules – change modules in minutes with no compromise in performance

 Open the catalog to page 1
NIRS XDS MasterLab Analyzer-2

The NIRS XDS MasterLab Analyzer based on XDS nearinfrared (NIR) technology, provides the next generation of dedicated NIR analysis for rapid non-destructive measurements of tablets, solids and liquids. With the MasterLab Analyzer you can replace routine tests, reduce product hold time and virtually eliminate quarantine time. The Analyzer supports acquisition of spectra in an unattended mode, freeing the operator to prepare other samples, analyze data, etc. The MasterLab Analyzer offers pharmaceutical manufacturers a rapid, reliable test method covering the full array of solid dosage forms: layered,...

 Open the catalog to page 2
NIRS XDS MasterLab Analyzer-3

The NIRS XDS MasterLab Analyzer consists of the following items • XDS Laboratory Monochromator XDS NIR technology ensures precise instrument matching and seamless calibration transfer. Hot-swappable interface allows rapid changing of additional sampling modules with no compromise in performance. Spectral coverage: 400-2’500 nm for reflectance, 850-1’600 nm for transmission. • XDS MasterLab Module Automated transmission and reflectance analysis of a tray of multiple tablets. Automated reflectance analysis of a tray of multiple vials. Integrated variable spot size for optimized sample illumination....

 Open the catalog to page 3
NIRS XDS MasterLab Analyzer-4

NIRS XDS MasterLab Analyzer Software 6.6069.102 Vision software 6.6069.103 Vision FDA complient software 6.6069.104 Vision multi user software 6.6069.105 Vision multi user FDA complient software 6.6069.106 Vision software for cascading libraries Standards 6.7450.000 NIRS Certified Reflectance Standards (set of 2 pc.) 6.7450.010 NIRS Certified Reflectance Standards (set of 7 pc.) Subject to modifications Layout by Ecknauer+Schoch ASW, printed in Switzerland by Metrohm AG, CH-9100 Herisau 8.921.5000EN – 2013-03

 Open the catalog to page 4
*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.