2Shape
1 / 12Pages

Catalog excerpts

2Shape - 2

New asymmetrical asymmetr cross section ti

Open the catalog to page 2
2Shape - 3

 etter resistance B to cyclic fatigue  ore flexibility M Respect of the original root can

Open the catalog to page 3
2Shape - 4

Simplified endodontics Intuitive sequence with 2 shaping instruments in continuous rotation. Instrumental dynamics TS1 and TS2  rogressive movement in three waves (3 up-and-down movements) with upward P circumferential filing movement. nsert the rotating instrument into the root canal until a resistance can be felt. I Perform a circumferential brushing movement when feeling the resistance in order to eliminate the primary constraints. Remove the file from the root canal, clean the grooves and irrigate the root canal. Then continue the progressive downward movement. 2Shape is...

Open the catalog to page 4
2Shape - 5

Safe endodontics Innovation Increased resistance to instrument fracture Proprietary Heat-Treatment process 2Shape Without heat-treatment technology more resistance to cyclic fatigue More flexibility  etter negotiation of curvatures. B  reservation of the elasticity of Nickel-Titanium. P * Data from Research and D

Open the catalog to page 5
2Shape - 6

Efficient endodontics MICRO-MEGA® presents its latest generation of cross section with triple helix: the perfect compromise between cutting efficiency and debris removal. 2 main cutting edges  or excellent F F cutting efficiency New asymmetrical cross section 1 secondary cutting edge  or improved debris F removal  o reduce constraints T The asymmetrical cross section:  educes the risk of instrument fracture1 R ncreases the efficacy of the circumferential brushing I movements for efficient selective cleaning2 Debris removal The 2Shape sequence allows a better removal of...

Open the catalog to page 6
2Shape - 7

Respect of the original root canal anatomy and more efficient cleaning of the root canal walls Superposition of a mandibular molar whose mesial roots were shaped with the 2Shape sequence (TS1 & TS2). 1. Effect of Asymmetry on the Behavior of Prototype Rotary Triple Helix Root Canal Instruments. Franck Diemer, Jérome Michetti, Jean-Philippe Mallet and Robert Piquet. J Endod – 2013 2. The Influence of Brushing Motion on the Cutting Behavior of 3 Reciprocating Files in Oval-shaped Canals. Shereen Alattar, DDS, DESE, Walid Nehme, DCD, DESE, Franck Diemer, DDS, MS, PhD, and Alfred Naaman, DDS,...

Open the catalog to page 7
2Shape - 8

Clinical cases Prof. Franck Diemer, France Preoperative x-ray of a patient’s necrotic 47 which received a crown reconstruction 6 months ago (glass ionomer cement + composite). Postoperative x-ray after shaping with 2Shape, apical finishing using F40 and obturation with pure thermomechanical condensation technique thanks to Revo Condensor. Obturation of the secondary canal in the center of the distal root and the apical delta of the mesial root. Prof. Walid Nehme, Lebanon Preoperative x-ray of a 16 and a 17, both with deep caries and acute pulpitis. Both molars were shaped using the 2Shape...

Open the catalog to page 8
2Shape - 9

Dr. Jean-Philippe Mallet, France Finally a rotary file system easy to learn, easy to use and easy to teach. Thanks a lot MICRO-MEGA®. Preoperative x-ray: upon diagnosis of pulp necrosis an initial endodontic treatment is indicated. The mesial root canals present a mineralized root canal lumen and a strong curvature and the distal canal an extremely curved apical third. Dr. Filippo Cardinali, Italy 2Shape perfectly meets my expectations of a shaping instrument: simplicity, efficiency and polyvalence. Beyond that, it perfectly preserves the root dentine. Dr. Jean-Pierre Siquet, Belgium...

Open the catalog to page 9
2Shape - 10

To complete your treatment Files for apical finishing F35 #35 .06  arge root L Thin root canals  traight root S canals Curved root canals canals Blister containing 200 paper points (6 points per

Open the catalog to page 10
2Shape - 11

2ShapePresentation + operating protocol 0459 Year of CE-marking: 2017 Medical device class IIA according to directive 93/42/EEC Certifying body: LNE/G-MED Medical device for dental care, meant for professional dental use only. See product labelling and, where applicable, instructions for use. sterile I eo Sterile devices Sterility guaranteed if package is unopened and undamaged. Can be sterilized in a steam sterilizer (autoclave) at the indicated temperature. MICRO-MEGA® 5-12, rue du Tunnel 25006 Besangon cedex - France www.micro-mega.com sterile I eo Sterile devices Sterility guaranteed if...

Open the catalog to page 11
2Shape - 12

Non contractual pictures - MICRO-MEGA® reserves the right to modify the characteristics of its products without prior notice. Ref. 60301807-B 03/18 MICRO-MEGA® 5-12, rue du Tunnel 25006 Besançon Cedex - France Tel.: +33 (0)3 81 54 42 36 commercial@micro-mega.com

Open the catalog to page 12

All Micro-Mega catalogs and technical brochures

  1. Catalogue 2019

    48 Pages

  2. Alto Surge

    38 Pages

  3. MM-ENDObook

    40 Pages

  4. Catalogue 2018

    48 Pages

  5. One-Curve

    12 Pages

  6. EndoUltraTM

    12 Pages

  7. One Flare

    6 Pages

  8. R-Endo

    2 Pages

  9. MM-MTA

    8 Pages

  10. SANAO

    6 Pages

  11. X-Cid® 2

    8 Pages

  12. MM.control

    6 Pages

  13. Revo-S®

    20 Pages