Spare Parts Catalogue
58Pages

{{requestButtons}}

Catalog excerpts

Spare Parts Catalogue - 1

Via Giotto 2 31021 Mogliano Veneto (TV) - ITALY Tel. +39.041.5937000 Fax. +39.041.5937011 e-mail: micromed@micromed.eu Internet: www.micromed.eu

Open the catalog to page 1
Spare Parts Catalogue - 4

Spare Parts Catalogue INTRODUCTION This Catalogue offers all spare parts that are possible to use along with the “System PLUS EVOLUTION” units. “System PLUS EVOLUTION” is the name of a group of systems divided as follows:     BRAIN QUICK HANDYEEG MYOQUICK MYOHANDY which indicates any Stationary PC based system for EEG which indicates any Laptop PC based system for EEG which indicates any Stationary PC based system for EMG and/or EP which indicates any Laptop PC based system for EMG and/or EP All these systems share the same software, that is “System PLUS EVOLUTION”, which has a common...

Open the catalog to page 4
Spare Parts Catalogue - 5

Spare Parts Catalogue AMPLIFIERS Amplifiers and JackBox for EEG – LTM New 48 Channel EEG Acquisition Headbox SD PLUS "Research" version New 38 Channel EEG Acquisition Headbox SD PLUS "Flexi" version SD PLUS HIGH RATE New 29 Channel EEG Acquisition Headbox SD PLUS "Flexi HighRate" version New 29 Channel EEG Acquisition Headbox SD PLUS "Flexi Clinic" version New 32 Channel LTM Headbox, needs JackBox New 64 Channel LTM Headbox, needs JackBox

Open the catalog to page 5
Spare Parts Catalogue - 6

Spare Parts Catalogue JackBox with 32 Common Reference Inputs, 21 arranged as Head Shape, 8 can be switched to Bipolar, to be used with SD LTM EXPRESS Series Headboxes JackBox with 64 Common Reference Inputs, 6 can be switched to Bipolar, to be used with SD LTM EXPRESS Series Headboxes JackBox with Double 37 pin D-Sub Connector and additional Touch Proof Inputs for Ground, Reference and 4 Bipolar Inputs, to be used with SD LTM EXPRESS Series Headboxes JackBox with Touch Proof Inputs for All Channels, including 8 Bipolar, Common Reference and Ground and Double 37 pin D-Sub Connector

Open the catalog to page 6
Spare Parts Catalogue - 7

Spare Parts CatalogueAmplifiers for PSG - Ambulatory Recorder BRAIN SPY PLUS BRAIN SPY PLUS Ambulatory Recorder. NOTE: Requires Memory Card (i.e. BS CARD 1024 or BS CARD 2048) MORPHEUS PSG Ambulatory Recorder. NOTE: Requires Memory Card (i.e. BS CARD 1024 or BS CARD 2048)

Open the catalog to page 7
Spare Parts Catalogue - 8

Spare Parts CatalogueSTIMULATORS Stimulators for EMG - EP

Open the catalog to page 8
Spare Parts Catalogue - 9

Spare Parts Catalogue Stimulators for LTM – Cortical Stimulation Cortical Stimulator to be combined with SD LTM 64 Series Amplifiers BATTERY PACK STIM External Battery Pack for Old SD LTM STIM Cortical Stimulator Model INTERFACES Interfaces for SD PLUS and SD LTM EXPRESS Interface Card working on PCI Express bus, to operate SD PLUS and SD LTM EXPRESS Headbox, with Triggers on Panel and Hardware Key USB Interface Card for SD PLUS and SD LTM EXPRESS Series Headbox Module to Interface SD PLUS e SD LTM EXPRESS (Include BQ USB EXPRESS), including Power Supply and Wall Mount Module to Interface...

Open the catalog to page 9
Spare Parts Catalogue - 10

Spare Parts Catalogue Interfaces for MORPHEUS and MATRIX Interface Card working on PCI bus, to operate MORPHEUS and MATRIX Headbox via Standard Cable, with Triggers on Panel and Hardware Key Interface Card working on PCI bus, to operate MORPHEUS and MATRIX Headbox via Standard Cable and/or via Fibre Optic, with Triggers on Panel and Hardware Key Interface Card working on PCI bus, to operate BQ PCI PLUS HALF Micromed Headbox via Standard Cable, with Triggers on Panel and Hardware Key, "Half Size" USB Interface Card for MORPHEUS and MATRIX Series Headbox Module to Interface MORPHEUS via...

Open the catalog to page 10
Spare Parts Catalogue - 11

Spare Parts CatalogueHEADBOX CABLESCables for SD PLUS Headbox Series Cables for SD PLUS on Interface BQ PCI EXPRESS LTM or BQ USB EXPRESS Connection via BOX TERMINAL on BQ PCI EXPRESS LTM or BQ USB EXPRESS CB TERMINAL 15 CB TERMINAL xx Cable to Connect Interfaces to BOX TERMINAL EXPRESS, length 15 m or "xx” to be specified Wall Box including circuits to connect SD PLUS and for trigger management (1 IN, 1 OUT) Needs cable CB TERMINAL xx to connect to the recording station and cables to connect to the Headbox HBC EXPRESS Length 5 m, without Trigger

Open the catalog to page 11
Spare Parts Catalogue - 12

Spare Parts Catalogue Cables for SD LTM EXPRESS Headbox Series Cables for SD LTM EXPRESS on BQ PCI EXPRESS LTM or BQ USB EXPRESS Q; BQ PCI EXPRESS LTM or BQ USB EXPRESS TERM EXPRESS BQ PCI EXPRESS LTM or BQ USB EXPRESS BQ PCI EXPRESS LTM or BQ USB EXPRESS

Open the catalog to page 12
Spare Parts Catalogue - 13

Spare Parts Catalogue Connection via BOX TERMINAL on BQ PCI EXPRESS LTM or BQ USB EXPRESS Cable to Connect Interfaces to BOX TERMINAL EXPRESS, length 15 m or “xx” to be specified Wall Box including circuits to connect SD LTM EXPRESS up to 256 channels and for trigger management (1 IN, 1 OUT) Needs cable CB TERMINAL xx to connect to the recording station and cables to connect to the Headbox Length 5 m, without Trigger TERM EXPRESS Terminal to Connect 1 SD LTM EXPRESS Series Headbox in 32 or 64 channel configuration, with Quick Disconnect Terminal to Connect 2 SD LTM EXPRESS Series TERM...

Open the catalog to page 13
Spare Parts Catalogue - 14

Spare Parts Catalogue Additional Wall Plug for SD LTM EXPRESS Headbox Additional Wall Plug for SD LTM EXPRESS Headbox, to be used in combination with a BOX TERMINAL EXPRESS WALL PLUG WALL PLUG TERM EXPRESS SD LTM 64 EXPRESS Headbox (Device Auto) Main Power Room A Synchronization Cable for SD LTM EXPRESS in 128 channel Ambulatory Mode Cable to Connect 2 SD LTM 64 EXPRESS Headbox for 128 channel Ambulatory Mode T OFF SD LTM 64 EXPRESS Headbox (Device First) SD LTM 64 EXPRESS Headbox (Device Second) CB LTM SYNC Connection Cable for Cortical Stimulator SD LTM STIM Cable to Connect Cortical /...

Open the catalog to page 14
Spare Parts Catalogue - 15

Spare Parts Catalogue Cables for MORPHEUS, SD LTM (Obsolete) Headbox Series Cables for MORPHEUS, SD LTM (Obs.) on Interfaces BQ USB or BQ PCI PLUS Terminal for Quick Disconnection of MORPHEUS or SD LTM Headbox Length 5 m, Without Trigger HBC INT LTM R cable, Length 5 m, with Quick Disconnection TERM LTM MORPHEUS (SD LTM) Electrically Powered MORPHEUS (SD LTM) Electrically Powered DC Inputs Isolation Box for MORPHEUS recorders DC Inputs Cable for MORPHEUS Headbox Cable to connect DC channels on MORPHEUS recorders

Open the catalog to page 15
Spare Parts Catalogue - 16

Spare Parts Catalogue Fibre Optic connection for MORPHEUS, SD LTM (Obs.) on BQ PCI PLUS FO Interface Fibre Optic, Standard Length from 5 to 100 m. Wall Box including FO PLUS circuit and SD POWER Needs Fibre Optic to connect to the Recording Unit and Headbox Cable to connect to the Headbox Cable to Connect FO PLUS to Quick Disconnect Terminal for Quick Disconnection of SD LTM Headbox MORPHEUS, SD LTM Headbox Electrically Powered Main Power Fibre Optic connection for MORPHEUS, SD LTM (Obs.) on BQ USB Interface The connection is the same as for BQ PCI PLUS FO with the addition of the FO...

Open the catalog to page 16