1. Catalogs
  2. MIKAI
  3. CLICKIT CF
video corpo

CLICKIT CF

CLICKIT CF
1 / 23 PagesView full catalog

CLICKIT CF

Product catalog summary
Overview: The document discusses Quick Connection Struts by Mikai S.p.A., designed for orthopedic uses such as fracture fixation, limb lengthening, and deformity correction. These struts are noted for their stability, lightweight design, and sterile condition, making them ready for immediate use.
Specifications: Made from an aluminum and stainless steel alloy, the struts are lightweight, stable, and resistant. They come in three configurations: static, telescopic monolateral, and telescopic bilateral, each offering specific compression/distraction capabilities.
Features: The struts feature a unique connection system that does not obstruct ring holes, allowing surgical flexibility. They include screw clamps for various screw sizes and oblique supports for optimal orientation. The system is compatible with different ring diameters and includes reinforced components for enhanced stability.
Components: The document lists components such as half rings, foot rings, ring segments, and various struts and screws, each with specific dimensions and configurations. Accessories like bolts, washers, and wire posts are also detailed.
Clinical Cases: Several clinical cases demonstrate the application of the ClickIt CF external fixator in trauma and orthopedic scenarios, highlighting its effectiveness in treating complex fractures, infections, and deformities, with successful recovery outcomes.
Instrumentation and Sterilization: The document outlines necessary instruments for strut application and provides sterilization guidelines, emphasizing autoclave sterilization for non-sterile instruments.
Case Overview: Details the treatment of a 25-year-old male with a sub-amputation of the left tibia due to road traffic trauma, treated with a FEP external fixator.
Initial Treatment: The patient underwent proximal lengthening osteotomy with an external fixator applied for stabilization.
Follow-Up and Complications: Follow-up X-rays were conducted 14 months post-operation and 2 months after fixator removal. Clinical follow-up occurred 1 month post-removal. Post-traumatic osteomyelitis was diagnosed 60 days after initial treatment.
Subsequent Procedures: Debridement of bone and soft tissue was performed in the infected area. Stabilization was achieved using ClickIt CF, and a double osteotomy addressed the bone defect. The external fixator was removed after 8 months, with follow-up X-rays and evaluations conducted 1 month post-removal.
Medical Team: Treatment was conducted by Dott. E. Scirica and Dott. R. Sciortino from Ospedale ARNAS Civico di Palermo, and Dott. C. Salomone from Ospedale Santa Maria di Misericordia di Albenga.
Manufacturer Information: Provided by Mikai S.p.A., headquartered in Genova, Italy, with a manufacturing facility in Monteviale, Italy.
See more

Catalog excerpts

CLICKIT CF-1

Quick connection struts Stable and Lightweight Sterile

 Open the catalog to page 1
CLICKIT CF-2

Indications Fractures, bone infections, deformities, non-unions and malunions. Applications Fracture fixation, limb lengthening, deformity correction, ankle arthrodesis and knee arthrodesis. CLINICAL ADVANTAGES Material: Aluminium and Stainless Steel Alloy Lightweight, stable and resistant Quick connection struts Quick and simple assembly Features Quick connection struts attach to an external portion of the half rings through a countersunk screw. This does not obstruct any of the ring holes, leaving them all free for surgery. The unique connection between the strut and the ring allows for a partial...

 Open the catalog to page 2
CLICKIT CF-3

Foot rings are available in several diameters. Foot ring extensions are available in 3 lengths. They connect to the ring through a countersunk screw that does not obstruct any of the holes of the ring. The foot ring hinged connection bolt allows for an optimal connection and orientation of the anterior ring. Screw clamps accept Ø4.0mm, Ø5.0mm and Ø6.0mm screws. The base of the clamp has slots that allow for an optimal orientation of the clamp to the bone. The wire bolt can be connected to the ring easily using an L Hexagonal wrench, thanks to a hexagonal hole on top. This is particularly beneficial...

 Open the catalog to page 3
CLICKIT CF-4

Components HALF RINGS Item No. Description Half Ring Ø 80 mm (2 pz) FOOT RINGS Item No. Description Foot Ring Ø 120 mm RING SEGMENTS Item No. Description Ring Segment Ø 140 mm

 Open the catalog to page 4
CLICKIT CF-5

COUNTERSUNK SCREW Item No. Description Ring connection bolt (10 pcs) CickIt Strut bolt (10 pcs) STATIC STRUTS Item No. Description Static Strut L 30 mm (2 pcs) MONOLATERAL TELESCOPIC STRUTS Item No. Description Monolateral Telescopic Strut L 65-80 mm (2 pcs) Monolateral Telescopic Strut L 80-110 mm (2 pcs) Monolateral Telescopic Strut L 100-150 mm (2 pcs) Monolateral Telescopic Strut L 150-250 mm (2 pcs) BILATERAL TELESCOPIC STRUTS Item No. Description Bilateral Telescopic Strut L 80-100 mm (2 pcs) Bilateral Telescopic Strut L 100-145 mm (2 pcs) Bilateral Telescopic Strut L 150-245 mm (2 pcs)...

 Open the catalog to page 5
CLICKIT CF-6

OBLIQUE SUPPORTS 45° Item No. Description Wire Bolt (2 pcs) Wire Bolt (4 pcs) Screw Bolt 1 Hole Sterile Screw Bolt 2 Holes Screw Bolt 3 Holes

 Open the catalog to page 6
CLICKIT CF-7

Description 1 Hole Screw/Wire Post 2 Hole Screw/Wire Post 3 Hole Screw/Wire Post Compression/Distraction Nut for Threaded struts Description Adaptation plate Description Universal hinge coupling

 Open the catalog to page 7
CLICKIT CF-8

Description Male hinge (2 pcs) Hybrid Connecting Post FEP Description Hybrid Connecting Post ClickIt ER FOOT RINGS ACCESSORIES Item No. Description Foot Ring Extension 5 Holes (2 pcs) Foot Ring Extension 5 Holes (2 pcs) Foot Ring Extension 5 Holes (2 pcs) Foot ring connection bolt Foot ring support (2 pcs) Foot ring support NON STERILE (2 pcs) Description K-wire Ø 1.8 mm L 400 mm NON STERILE Olive K-wire Ø 1.8 mm L 400 mm NON STERILE K-wire Ø 1.8 mm L 400 mm Titanium NON STERILE K-wire Ø 1.8 mm L 400 mm Titanium (5 pcs) Mikai S.p.A.

 Open the catalog to page 8
CLICKIT CF-9

Screws HA COATED UNIVERSAL STAINLESS STEEL SCREWS Item No. HA coated self drilling cortical screw Ø 4.0 mm L 150 mm, thread L 40 mm HA coated self drilling cortical screw Ø 4.0 mm L 150 mm, thread L 55 mm HA coated self drilling cortical screw Ø 5.0 mm L 150 mm, thread L 40 mm HA coated self drilling cortical screw Ø 5.0 mm L 150 mm, thread L 55 mm HA coated self drilling cortical screw Ø 5.0 mm L 150 mm, thread L 70 mm HA coated self drilling cortical screw Ø 6.0 mm L 150 mm, thread L 40 mm HA coated self drilling cortical screw Ø 6.0 mm L 150 mm, thread L 55 mm HA coated self drilling cortical...

 Open the catalog to page 9
CLICKIT CF-10

STAINLESS STEEL SCREWS Item No. Description Self drilling cortical screw Ø 4.0 mm L 80 mm Self drilling cortical screw Ø 4.0 mm L 100 mm Self drilling cortical screw Ø 4.0 mm L 120 mm Self drilling cortical screw Ø 4.0 mm L 140 mm Self drilling cortical screw Ø 5.0 mm L 80 mm Self drilling cortical screw Ø 5.0 mm L 100 mm Self drilling cortical screw Ø 5.0 mm L 120 mm Self drilling cortical screw Ø 5.0 mm L 140 mm Self drilling cortical screw Ø 5.0 mm L 160 mm Self drilling cortical screw Ø 6.0 mm L 100 mm Self drilling cortical screw Ø 6.0 mm L 120 mm Self drilling cortical screw Ø 6.0 mm L...

 Open the catalog to page 10
CLICKIT CF-11

Hexagonal screwdriver long 3 mm Tubular wire Tensioner Wire cutter Wire bending pliers Stainless Steel Ruler Adapter for wire tensioner Empty sterilization tray for ClickIt CF * Implantable and sterile devices are covered by CE Mark 1936 mark, non-sterile reusable instruments are covered by the CE marked. Sterilization All ClickIt CF components are supplied sterile. For instruments, sterilization must be performed in autoclave using saturated steam with the following parameters: TEMPERATURE: 134°

 Open the catalog to page 11
CLICKIT CF-12

Clinical cases CASE 1 Dott. G. Caizzi, Prof. B. Moretti - Clinica Ortopedica e Traumatologica, Università degli Studi di Bari Road traffic trauma Debridement and reduction using K wires Post-operative necrosis Reduction using ClickIt CF external fixator and microvascular skin flap at 4 months from the trauma Subsequent correction of the equine foot using the external fixator Clinical Follow-up after 1 year

 Open the catalog to page 12
CLICKIT CF-13

Dott. M. Commessatti, Dott. D. Tigani - Ortopedia e Traumatologia, Ospedale Maggiore di Bologna Stabilization using temporary external fixator Skin necrosis after 2 weeks Treatment using VAC therapy, ClickIt CF external fixator and skin grafts. X-rays after 5 months, before the removal of the external fixator X-rays 3 months after the removal of the external fixator Complete recovery of the joint Sport related injury Open distal tibia fracture (III A) X-ray

 Open the catalog to page 13
CLICKIT CF-14

Dott. M. Commessatti, Dott. D. Tigani - Ortopedia e Traumatologia, Ospedale Maggiore di Bologna Road traffic trauma Open distal tibia fracture, Type II Emergency treatment using ClickIt CF Post-operative x-rays Fracture healed after 4 months X rays 1 month after the removal of the external fixator Complete recovery of the joint

 Open the catalog to page 14

All MIKAI catalogs and technical brochures

  1. MINISTYLO

    8  Pages

  2. CLICKIT STYLO

    7  Pages

  3. SMART SYSTEM

    2  Pages

  4. BLUE SHARK

    2  Pages

Archived catalogs

*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.