Catalog excerpts

CLICKIT STYLO - 1

Quick connection clamps Versatile and modular Ball joint unit

Open the catalog to page 1
CLICKIT STYLO - 2

Indications Intra and extra articular fractures of the wrist: •  unstable radius/ulna fractures •  open radius/ulna fractures •  fractures of the radius/ulna associated with severe soft tissue injuries CLINICAL BENEFITS Features several unique accessories Material: Aluminium and Steel alloy Body of the fixator The ball joint simplifies the fracture reduction and allows for a correction in all planes. Quick connection clamps The coupling of the clamp to the body of the fixator is independent to the coupling of the clamp to the screws. In cases where a greater stability is required, the many...

Open the catalog to page 2
CLICKIT STYLO - 3

Key surgical steps Perform a 1 cm incision in proximity of the metaphysis of the second metacarpal along the dorsal-radial margin, lateral to extensor tendon. Using the drill guide, insert two screws with 2.5 thread at approximately a 45-degree angle of the horizontal plane in the metacarpal. Use a power tool to go past the first cortex and then proceed by using the T handle. Perform a 1 cm incision in the radius at an adequate distance from the fracture. To facilitate the latter, use the body of the fixator as a unit of measure. The ball joint should be in proximity of the radio-carpal...

Open the catalog to page 3
CLICKIT STYLO - 4

Perform the reduction. Using the 3 mm wrench block the ball joint and secure the proximal clamp. In case the proximal clamp is very close to the end of the body of the external fixator, it is advised to use the extension rod that is available as an accessory. Make sure all the clamps have been tightened securely by using the 5000625 wrench. If the fracture pattern requires it, it is possible to attach an arch to the fixator and position additional screws and k-wires in the bone. Compression Distraction Unit Attach the fork of the compression distraction unit to the proximal part of the...

Open the catalog to page 4
CLICKIT STYLO - 5

Clinical Case Dr M. Corain - Verona University Hospital / UOC Hand Surgery Unit CT scan after 14 days Treated with a cast X-ray after 14 days Removal of cast due to pain and slight exposure of the head of the ulna Fixation using ClickIt Stylo and K-wires Post-operative x-ray Removal of the external fixator after 40 days Follow up x-ray and clinic after 4 months

Open the catalog to page 5
CLICKIT STYLO - 6

ORDERING INFORMATION Item No. ClickIt Stylo rod extension 40 mm ClickIt Stylo single clamp (one screw/K-wire) ClickIt Stylo single open-ended clamp ClickIt Stylo T-clamp (two screws/K-wires) ClickIt Stylo double clamp (two screw/K-wire) Arch 120° with screw clamp Clamp for arch support Self drilling screw Ø 3.0 mm L 60 mm thread 20 mm Self drilling screw Ø 3.0 mm L 70 mm thread 20 mm Self drilling screw Ø 3.0 mm L 80 mm thread 20 mm Self drilling screw Ø 3.0 mm L 90 mm thread 20 mm Self drilling screw Ø 3.0 mm L 50 mm thread Ø 2.5 mm L 12 mm Self drilling screw Ø 3.0 mm L 60 mm thread Ø 2.5...

Open the catalog to page 6
CLICKIT STYLO - 7

Via P. Gobetti, 56r - 16145 Genova - Italy Tel. +39 010 30801 - Fax +39 010 3080210 www.mikai.it - servizio.clienti@mikai.it MANUFACTURING FACILITY Via Canestrello, 2 - 36050 Monteviale (VI) - Italy Tel. +39 0444 950100 - Fax +39 0444 950133 www.mikai.it - servizio.clienti@mikai.it All images are for illustrative purposes only 2020 © MIKAI S.p.A. VAT 00972790109 - All rights reserved