Safety anaesthesia workstation SIGMA 70 & 120
16Pages

{{requestButtons}}

Catalog excerpts

Safety anaesthesia workstation SIGMA 70 & 120 - 1

Safety anaesthesia workstation SIGMA 70 & 120

Open the catalog to page 1
Safety anaesthesia workstation SIGMA 70 & 120 - 2

Our company was established under the name MINERVE Medical in 1953, and since then it has stuck to its original vocation of designing, manufacturing and distributing medical equipment. At the time it focused on both human and veterinary medicine. With a growing need for specialisation, MINERVE broadly focused on veterinary science. As a reorganised company, it joined the animal health department of the SANOFI group in 1980. In 1993 its veterinary medical equipment branch was sold to a group employee. The company EQUIPEMENT VETERINAIRE MINERVE was then established in its present form. The...

Open the catalog to page 2
Safety anaesthesia workstation SIGMA 70 & 120 - 3

Concept : Minerve’s anaesthesia workstation are devices designed to ensure a safe and controlled working area to perform anesthesia on smalls animals with the aim of adapting to the different constraints of installation and use in a laboratory environment (SIGMA 120 version 2 indépendants working area) (SIGMA 120 version 4 multiples induction box for big series of animals, prelevement) (SIGMA 120 version 2 postes) The different versions available can meet the majority of user needs, the trays are interchangeable to ensure different configuration possibilities. (Compatible disinfection...

Open the catalog to page 3
Safety anaesthesia workstation SIGMA 70 & 120 - 4

General présentation : Automatic induction box Integrated Air pump/concentrat or 9004007PH/1301 446 Ajustable braked castors Thermo regulated suction trays Large accessories drawer Active carbon filter 40 liters 1301661

Open the catalog to page 4
Safety anaesthesia workstation SIGMA 70 & 120 - 5

Vaporizer TEC 3 5151608 Mix of input 2 gases Touch Screen 7" Thermo regulated suction trays Large accessories drawer Integrated air pump/oxygene concentrator 9004007PH/1301446 Active carbon filter 25 liters 1301719 Ajustable braked castors

Open the catalog to page 5
Safety anaesthesia workstation SIGMA 70 & 120 - 6

The input gases are combined to produce a carrier gas, this gaseous mixture is sent to the vaporizer to be loaded with anesthetic agent. Then it’s distributed to each accessories channels that control activation, concentrations and utilization rates independantly. The central aspiration system captures and filters the anesthetic agents through an integrated activated carbon cartridge. It is also possible not to use internal activated carbon cartridges and return the stale air to a suitable reprocessing system (cartridges or HVAC system)

Open the catalog to page 6
Safety anaesthesia workstation SIGMA 70 & 120 - 7

Fonctionnalités : IHM Interface Human Machine Clogging indicator of the air filter or hepa filter (2) Management of the set temperature surgical plan and display of the animal’s temperature (1) Management of the type Secure vaporizer filling assistant Indicator of the saturation state of the active carbon filter Automatic or manual gestion of the extraction system (3) Automatic detection of accessory type (2) Parameters and realtime contrôle of the flow (2) Set the concentration of anaesthesic agent independantly on each way (2) Gestion and real time control of temperature of each tray The...

Open the catalog to page 7
Safety anaesthesia workstation SIGMA 70 & 120 - 8

(1) Set the concentration of anaesthesic agent A system of quick shortcuts makes possible to define 3 favorite values for the following parameters: Flow rate, concentration and the set temperature for the surgical plans/ heating plates. A system of automatic detection of the connected accessory (cage or mask) allows to optimize the consumption of the anesthetic gas and informs the user of the status of each accessory (mask occupied, waiting, cage open, cage saturated ... ).

Open the catalog to page 8
Safety anaesthesia workstation SIGMA 70 & 120 - 9

Elements and security routines : Détails of extraction system : A high-capacity activated carbon filter ensures the capture and neutralization of residual anesthesics agents. A pre-filter and / or HEPA FILTER is avaible as an alternative to the active carbon filter and can be used when the table is connected to the laboratory’s air handling system, in accordance with the specific health and environmental constraints associated with the location installation. The suction flow is enslaved to ensure a constant efficienty of the extraction system regardless of the filter level of clogging by...

Open the catalog to page 9
Safety anaesthesia workstation SIGMA 70 & 120 - 10

Elements and security routines Filling vaporizer wizard : The "anesthesia filling" wizard has been developed to ensure that the user is not exposed during the filling phase of the vaporizer due to the presence of residual pressure when the latter is opened. In fact, even an ISOTEC7 type vaporizer can not contain the residual pressure during the filling phases. This wizard ensures that the system pressure has dropped to 0mb before asking the user to open the evaporator to fill.

Open the catalog to page 10
Safety anaesthesia workstation SIGMA 70 & 120 - 11

Elements and security routines : System alarms : The operating system of the SIGMA 70 permanently monitors all the parameters related to anesthesia, with the aim of guaranteeing maximum user safety while optimizing the consumption of halogenated agents. Below is a list of the checks performed by the table in real time: - Inlet gas pressures 1 and 2 external - Inlet gas pressures 1 and 2 internal (concentrator and Hf air pump) - Extraction flows - Clogging condition of the hepa pre-filter - Saturation state of the activated carbon filter - Anesthesia output flow value corresponds to the set...

Open the catalog to page 11
Safety anaesthesia workstation SIGMA 70 & 120 - 12

Optical detector presence rat / mouse mask: The presence of the animal on the anesthetic mask is performed without contact by an infrared type optical detector. It is equipped with a green led to ensure a visual check of the flow status (Flashing: Off / On: sending in progress) Surgical mask for Rat/Mouse : INOX surgical mask with coaxial suction. The muzzle of the animal is surrounded by a silicone membrane to limit isoflurane leakage, and release the maximum space at the head, the surplus is redirected to the extraction system through the suction located on the outskirts. The mask is...

Open the catalog to page 12
Safety anaesthesia workstation SIGMA 70 & 120 - 13

Multi-mask support for Rat or Mouse: Allows to maintain under anesthesia up to 6 mice or 4 rats simultaneously. Each outlet is equipped with an independent manual shut-off valve to shut off the supply of anesthetic mixture independently. The main advantage of this ramp is the use of a single gas outlet and avoid the multiplication of anesthesia circuits on the workspace; it must be fixed on a perforated tray by means of dedicated mask holders. The aspiration of the tray ensures the aspiration of all residual anesthetics. Masks of anesthesia big animals: Allows to maintain under anesthesia...

Open the catalog to page 13