Principle of Hair Removal
The laser hair removal device operates on selective photothermal dynamics, utilizing mixed wavelengths (755nm, 808nm, 940nm, 1064nm) to target and destroy hair follicles by converting light energy into thermal energy. A cooling mechanism is included to protect the skin and ensure a painless experience.

Scope and Cycle of Application
The device is suitable for hair removal on lips, armpits, arms, legs, and bikini areas. Optimal results are achieved during the hair's growth phase, requiring multiple treatments based on hair density and color.

First Hair Removal Process
The process includes consultation, skin assessment, shaving, cooling gel application, irradiation, and post-treatment cooling.

Technical Parameters
The instrument features adjustable wavelengths, energy density, and pulse width, with a TEC sapphire cooling system and a 15.6-inch screen. It operates on a 220V/110V power supply and has a durable handle with high shot capacity.

Advantages of New Handle Model
The new handle model improves energy focus, increases shot capacity, and reduces treatment time. It uses sapphire crystal for better energy penetration and comfort.

Clinical Operations
Operators must be trained professionals. The system is suitable for all skin types and uses cooling technology for comfort. Contraindications include skin cancer, pregnancy, and certain medical conditions. Preoperative instructions involve medical history review and skin assessment.

Photography and Preoperative Instructions
Photographic documentation is recommended to track treatment progress, with consistent conditions for accurate comparison.
Introduction
This document provides guidelines for using the Soprano 755 + 808 + 940 + 1064nm Diode Laser for hair removal, covering pre-treatment considerations, clinical operations, treatment parameters, postoperative care, and follow-up recommendations.

Pre-Treatment Considerations
Patients should avoid artificial sunbathing within 48 hours of treatment and prolonged sun exposure. Preventive medication is advised for those with a history of herpes simplex in the treatment area. Discuss treatment goals and expectations with patients.

Consultation Services
During consultations, clarify the patient's reasons for treatment and expectations. Multiple sessions over several months are required, with potential discomfort or temporary side effects.

Clinical Operations
Treatment Procedure:
1. Ensure patient comfort and use protective eyewear.
2. Remove skin products like perfume or sunscreen.
3. Record pulse numbers for energy calculation.
4. Select and save treatment settings.
5. Ensure the handpiece is cold and in contact with the skin.
6. Conduct skin tests to monitor reactions.
7. Adjust parameters if side effects occur.
8. Gradually increase energy if no adverse reactions are observed.

Warnings:
Protective goggles are mandatory to prevent eye damage. Avoid treating lighter-colored hairs than the surrounding skin.

Treatment Parameters
The system is preset based on experienced users' conclusions, but parameters like skin color type, laser energy density, and repetition frequency can be adjusted.

Postoperative Care
Use cold gel or ice packs to reduce redness and discomfort. Avoid trauma, hot baths, exercise, and sun exposure for a specified period. Apply high-index sunscreen and avoid direct sunlight for at least a month post-treatment.

Treatment Side Effects
Photosensitivity or improper operation may cause itchy skin.

Follow-up
Re-examine patients within 4 weeks post-operation, with follow-up treatments as needed based on individual hair growth cycles. Sun protection is advised throughout the treatment course.

Operational Precautions
1. Connect the instrument to the designated power supply.
2. Read the instruction manual thoroughly.
3. Conduct treatments in an isolated room.
4. Use pure water for cooling and update monthly.
5. Gradually adjust parameters and monitor customer comfort.
6. Avoid water contact with the touch screen.
7. Clean and prepare the treatment area, ensuring protective measures are in place.
8. Check the cooling condition of the handpiece.
9. Certain conditions like diabetes or photosensitivity may contraindicate treatment.
10. Redness post-treatment is normal and should subside within 24 hours.
11. Avoid direct eye exposure to the laser.
12. Ensure proper contact with the skin during operation.
13. Avoid targeting black objects with the laser.
See more

Catalog excerpts

4 wavelength Diodelaser-1

New 755nm-808nm-940nm1064nm Mixed Wavelength Laser Hair Removal Instrument In st r u ct i o n Ma nu al

 Open the catalog to page 1
4 wavelength Diodelaser-3

C h a p t e r On e Th e Pr i n c i p l e of Ha i r Re m o v a l 1 . 1. The principle of 755nm-808nm-1064nm mixed wavelength ice point hair removal 75 5nm -80 8n m -1 06 4n m mix e d wa v e le ng t h ic e po in t is ba se d on the pr i n c i p l e of se l e c t i v e ph o t o t h e r m a l dy n a mi c s . By pr o p e r ly ad ju s t i n g th e la s e r wa v e l e n g t h , ene r g y an d pu l s e wi d t h , th e li g h t en e r g y passes throug h the skin su rface to the root hair follicles of the hair, is a b s o r b e d a n d co n v e r t e d in t o th e r m a l en e r g y t h a t de s t r o...

 Open the catalog to page 3
4 wavelength Diodelaser-4

C h a p t e r On e Th e Pr i n c i p l e of Ha i r Re m o v a l 1.3. Hair removal cycle Onl y whe n 75 5 n m -8 0 8 n m - 1 0 6 4 n m mi x e d wa v e l e ng t h ice po in t ha i r rem ova l is ca rried out during the gr o wth period can the best effect be ac h i e v e d . Du r in g th e gr o w t h pe ri o d , the pi g m e nt pa r t ic l e s pr od u c e d in the hair fo llicle s ca n fully ab sor b the the rm a l ener g y. At this tim e, th e ha ir fol li c le s ar e the mos t vu lne r a bl e , and the ef fe ct of hair rem ov al is bound to be the best . The numb er of treat ments is also related...

 Open the catalog to page 4
4 wavelength Diodelaser-5

Chapter Two Technical Parameters 2. 1 . Tec hn ic a l par am et er s of the new 808nm ic e poin t hair removal Wavelength Wo r k i n g fr e q u e n c y TEC*Sapphire cooling Spot (light exit port) La s e r po w e r Output mode Pulse output Water temperature DP-60 diaphragm pump, 12V power supp ly Fo ur 22 0V silent fans, ro tation speed 315 0r/min Exclusive customization Boot logo, store name, brand, etc., minimum order quantity is one unit.

 Open the catalog to page 5
4 wavelength Diodelaser-6

Chapter Two Technical Parameters 2. 2 . New 755 nm - 808 nm -94 0n m -10 64n m mix ed wa vel en g th ic e poi nt depilator & hair removal handle Mainframe

 Open the catalog to page 6
4 wavelength Diodelaser-7

Chapter Two Technical Parameters 2. 3 . Ni n e ma j o r ad v a n t a g e s of th e co m p a r i s o n be t w e e n th e ne w an d ol d ha n d l e mo d e l s Collimated light, energy light output, more focused and concentrated Old laser Non-colli mated light, the energy light output is relatively scattered and the effect is not ideal Super strong light. The energy light output is mo r e fo c u s e d an d co n c e n t r a t e d. Th e ef f e c t iv e ligh t and ener gy ar e in crea se d by 5 tim es, and the comfort level is better. Non-super strong light. The energy light output is re l a t i v e...

 Open the catalog to page 7
4 wavelength Diodelaser-8

Chapter Two Technical Parameters The number of shots of the handle: The new model has 20 million shots , and the number of shots of the new model is four times that of the old on e . The old model has 5 million shots . Handle power: The power of the new handle is 1200W , and the total power is 3000 watts . The power of the new model is twice that of the old m od e l. Small and exquisite , lighter and more delicate . It 's easier and not tiring to operate for hair removal. Big , clumsy . The operation is prone to making the hands sore and getting tired New model: Imported military-grade laser...

 Open the catalog to page 8
4 wavelength Diodelaser-9

Chapter Two Technical Parameters Instrument operation interface Homepage Operation Interface New 755nm-808nm -940nm -1064nm Mixed Wav elength Laser Hair Removal Instrument

 Open the catalog to page 9
4 wavelength Diodelaser-10

Chapter Two Technical Parameters Pulse Width Temperature Water Flow New 75 5nm-808nm-940nm-1064nm Mixed Wavelength Laser Hair Removal Instrument

 Open the catalog to page 10
4 wavelength Diodelaser-11

Chapter Two Technical Parameters Handle Installation 1. A is align ed with position B and inserted all th e way to the bottom . ↑ 2. Screw to the left and right horizontal position. New 755nm-808nm 940nm -1064nm Mixed Wavelength Laser Hair Removal Instrumen

 Open the catalog to page 11
4 wavelength Diodelaser-12

Chapter Two Technical Parameters Light Outlet Touch Control Handle Light Emission Button The small light exit port can be used to operate are a s of di f f e re n t si z e s . The small light exit port has stronger energy and better effect. The large light exit port is used to operate large areas. New 755nm-808nm-040nm- 1064nm Mixed Wav elength Laser Hair Removal Instrument

 Open the catalog to page 12
4 wavelength Diodelaser-13

Chapter Two Technical Parameters Body part Lip Hair Beard Armpit Arms Hair Leg Hair Bikini 1. When operating on each part, it is necessary to adjust from the lowest energy level first, and then gradually increase the energy until the maximum energy that the customer can accept. 2. The operating time and the number of shots should be appropriately adjusted according to the actual situation of the customer. 3. The greater the energy, the longer the treatment time, and the better the effect will be. But it should not be excessive to avoid causing discomfort to the customer's skin. 4. After the treatment,...

 Open the catalog to page 13
4 wavelength Diodelaser-14

Chapter Three Clinical Operations 3 . 1 . Introduction This section can provide assistance to professionals using the new Soprano 755 + 808 + 940+1064nm Diode Laser freezing point hair rem oval system . T h e at t a c h m e n t ad d s an d em p h a s i z e s th e in t r o d uc t io n of us a g e , pre v e n t i o n an d wa rn in g in f o r m a ti on to re d u c e th e oc c u rre n ce of dangers in the operation manual. All operators should read the entire op er ation man u al th o ro u g h ly be fo re re ad in g th is sec tio n an d operating the system . 3 . 2. Training Requirements The design...

 Open the catalog to page 14
4 wavelength Diodelaser-15

New 755nm-808nm-940nm- 1064nm Mixed Wav elength Laser Hair Removal Instrument

 Open the catalog to page 15
4 wavelength Diodelaser-16

Chapter Three Clinical Operations 3 . 4 . Contraindications Cancer , especially skin cancer Pregnancy (including IVF) Use of photosensitive drugs and traditional Chinese medicine Disorders that are easily stimulated at a wavelength of Soprano 755 + 808 + 1064nm D iode L aser nanom eters Sun exposure or artificial sunbathing in the 3 to 4 weeks before treatment Active inflammation or herpes simplex infection in the treatment area History of keloid Diabetes (relying on insu lin injection) Dry and sensitive skin Endocrine disorders (strong light can cause irritation) Use of anticoagulants Epilepsy...

 Open the catalog to page 16
4 wavelength Diodelaser-17

Chapter Three Clinical Operations Energy Density The energy density output (joules/ cm² ) is set by the operator during each treatment. Energy density is: the total energy (joules) output un d e r th e se le ct e d pul s e ty p e / th e sp o t are a (cm ² ) . When the spot is sm aller (1 5X15m m ) , the scattering is the sm allest , so the result is a continuous energy output and deeper penetration . The greater the energy density , the higher the temperature of the target tissue hair , surrounding tissues and epiderm is . B efo re trea tm e n t The treatment parameters depend on the skin type...

 Open the catalog to page 17

Archived catalogs

  1. Morpheus8 RF-2

    32  Pages

  2. DL4

    6  Pages

  3. Miramhoo-HRL2

    6  Pages

  4. Miramhoo-DL5

    6  Pages

  5. Miramhoo-DL4

    6  Pages

  6. 22D HIFU-1

    9  Pages

  7. Shockwave ESWT

    19  Pages

  8. Skin analysis-1

    11  Pages

  9. Miramhoo-HL2

    5  Pages

  10. truSculpt ID

    6  Pages

*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.