1. Catalogs
  2. Miramhoo Aesthetics
  3. Diode laser TEC Cooling 50 million shots

Diode laser TEC Cooling 50 million shots

Diode laser TEC Cooling 50 million shots
1 / 20 PagesView full catalog

Diode laser TEC Cooling 50 million shots

Product catalog summary
Introduction
This document serves as an instruction manual for the New 755nm-808nm-1064nm Mixed Wavelength Laser Hair Removal Instrument, detailing its principles, technical specifications, and clinical operations.

Principle of Hair Removal
The device operates on selective photothermal dynamics, using mixed wavelengths (755nm, 808nm, 1064nm) to target and destroy hair follicles, preventing regrowth. It includes a cooling mechanism for epidermal protection and a painless experience.

Scope and Cycle of Application
Suitable for hair removal on lips, armpits, arms, legs, and bikini areas, with optimal results during the hair growth phase.

Technical Parameters
Features adjustable frequency (1-10Hz), energy density (1-150J/cm²), and pulse width (1-400ms). Includes a TEC sapphire cooling system, various spot sizes, and operates on 220V/110V with a 7L water tank.

Advantages of New Handle Model
The new handle model uses sapphire crystal for enhanced energy penetration and durability, offering focused light output, reduced treatment time, and increased comfort.

Clinical Operations
Operators must be trained and familiar with the manual. Suitable for all skin types, with cooling technology for comfort. Contraindications include skin cancer, pregnancy, and certain medical conditions. Emphasizes adjusting energy levels based on patient needs.

Photography and Documentation
Recommends taking before-and-after photos to document treatment progress, ensuring consistent conditions for accurate comparison.
Preoperative Instructions
Patients should bring medical records, avoid sun exposure 48 hours prior, and undergo preventive treatment for herpes simplex if necessary. Discuss treatment goals and expectations.

Treatment Procedure
Ensure patient comfort, use protective glasses, remove skin products, record pulse numbers, adjust parameters based on skin reaction, and cool the area post-operation.

Treatment Parameters
Consider skin color type, laser energy density, and repetition frequency.

Postoperative Care
Use cold gel or ice packs to reduce redness, avoid trauma, hot baths, exercise, and sun exposure for several days, and apply high-index sunscreen for at least a month.

Treatment Side Effects
Possible side effects include itchy skin due to photosensitivity or improper operation.

Follow-up
Re-examine patients within 4 weeks, adjust based on hair growth cycles, and advise on sun protection.

Operational Precautions
Connect to designated power supply, use pure water for cooling, update monthly, adjust parameters gradually, and ensure proper handpiece cooling. Patients with conditions like diabetes or photosensitivity are not suitable for treatment.
See more

Catalog excerpts

Diode laser TEC Cooling 50 million shots-1

New 755nm-808nm-1064nm Mixed Wavelength Laser Hair Removal Instrument Instruction Manual

 Open the catalog to page 1
Diode laser TEC Cooling 50 million shots-2

Chapter One The Principle of Hair Removal 1.1.The principle of 755nm-808nm-1064nm mixed wavelength ice point hair removal 755nm-808nm-1064nm mixed wavelength ice point is based on the principle of selective photothermal dynamics. By properly adjusting the laser wavelength, energy and pulse width, the light energy passes through the skin surface to the root hair follicles of the hair, is absorbed and converted into thermal energy that destroys the hair follicle tissue, thereby making the hair lose its regenerative ability. The extremely fast ice point hair removal system adopts a unique freezing...

 Open the catalog to page 2
Diode laser TEC Cooling 50 million shots-3

Chapter One The Principle of Hair Removal 1.3.Hair removal cycle Only when 755nm-808nm-1064nm mixed wavelength ice point hair removal is carried out during the growth period can the best effect be achieved. During the growth period, the pigment particles produced in the hair follicles can fully absorb the thermal energy. At this time, the hair follicles are the most vulnerable, and the effect of hair removal is bound to be the best. The number of treatments is also related to the hair density, color and the proportion of hair follicles in the resting period in the treatment area. Generally, obvious...

 Open the catalog to page 3
Diode laser TEC Cooling 50 million shots-4

New 755nm-808nm-1064nm Mixed Wavelength Laser Hair Removal Instrument

 Open the catalog to page 4
Diode laser TEC Cooling 50 million shots-5

Chapter Two Technical Parameters 2.2.New 755nm-808nm-1064nm mixed wavelength ice point depilator & hair removal handle New 755nm-808nm-1064nm Mixed Wavelength Laser Hair Removal Instrument

 Open the catalog to page 5
Diode laser TEC Cooling 50 million shots-6

Chapter Two Technical Parameters 2.3.Nine major advantages of the comparison between the new and old handle models New 755nm-808nm-1064nm mixed wavelength handle Collimated light, energy light output, more focused and concentrated Non-collimated light, the energy light output is relatively scattered and the effect is not ideal Quartz or K9 glass, the penetrability of energy light is only 60-80%, and it is fragile and prone to cracking at high temperatures. The first model adopts the best crystal in the industry: sapphire crystal. Sapphire crystal, the penetrability of energy light can reach 99.9%,...

 Open the catalog to page 6
Diode laser TEC Cooling 50 million shots-7

Chapter Two Technical Parameters The old model has 5 million shots. Handle power: The power of the new handle is 1200W, and the total power is 3000 watts. The power of the new model is twice that of the old model. The old model is 600 watts, and the total power is 1500 watts. The number of hair removal sessions: The new model only requires 1 - 5 times. The old model requires 6 - 10 times. Small and exquisite, lighter and more delicate. It's easier and not tiring to operate for hair removal. Big, clumsy. The operation is prone to making the hands sore and getting tired New model: Imported military-grade...

 Open the catalog to page 7
Diode laser TEC Cooling 50 million shots-8

Chapter Two Technical Parameters Instrument operation interface Homepage Operation Interface New 755nm-808nm-1064nm Mixed Wavelength Laser Hair Removal Instrument

 Open the catalog to page 8
Diode laser TEC Cooling 50 million shots-9

Chapter Two Technical Parameters Operation Interface Pulse Width Frequency Part Water Temperature Water Flow New 755nm-808nm-1064nm Mixed Wavelength Laser Hair Removal Instrument

 Open the catalog to page 9
Diode laser TEC Cooling 50 million shots-10

Chapter Two Technical Parameters Handle Installation 1. A is aligned with position B and inserted all the way to the bottom. ↑ 2. Screw to the left and right horizontal position. New 755nm-808nm-1064nm Mixed Wavelength Laser Hair Removal Ins

 Open the catalog to page 10
Diode laser TEC Cooling 50 million shots-11

Chapter Two Technical Parameters Light Outlet Touch Control Handle Light Emission Button The small light exit port can be used to operate areas of different sizes. The small light exit port has stronger energy and better effect. The large light exit port is used to operate large areas. New 755nm-808nm-1064nm Mixed Wavelength Laser Hair Removal Instrument

 Open the catalog to page 11
Diode laser TEC Cooling 50 million shots-12

Chapter Two Technical Parameters Operate closely against the skin. Body part Lip Hair Beard Armpit Arms Hair Leg Hair Bikini 1. When operating on each part, it is necessary to adjust from the lowest energy level first, and then gradually increase the energy until the maximum energy that the customer can accept. 2. The operating time and the number of shots should be appropriately adjusted according to the actual situation of the customer. 3. The greater the energy, the longer the treatment time, and the better the effect will be. But it should not be excessive to avoid causing discomfort to the...

 Open the catalog to page 12
Diode laser TEC Cooling 50 million shots-13

Chapter Three Clinical Operations 3.1. Introduction This section can provide assistance to professionals using the new Soprano 755+808+1064nm Diode Laser freezing point hair removal system. The attachment adds and emphasizes the introduction of usage, prevention and warning information to reduce the occurrence of dangers in the operation manual. All operators should read the entire operation manual thoroughly before reading this section and operating the system. 3.2. Training Requirements The design of the new Soprano 755+808+1064nm Diode Laser freezing point hair removal system requires the...

 Open the catalog to page 13
Diode laser TEC Cooling 50 million shots-14

Chapter Three Clinical Operations 3.4. Contraindications ŸCancer, especially skin cancer ŸPregnancy (including IVF) ŸUse of photosensitive drugs and traditional Chinese medicine ŸDisorders that are easily stimulated at a wavelength of Soprano 755+808+1064nmDiode Laser nanometers ŸSun exposure or artificial sunbathing in the 3 to 4 weeks before treatment ŸActive inflammation or herpes simplex infection in the treatment area ŸHistory of keloid ŸDiabetes (relying on insulin injection) ŸDry and sensitive skin ŸEndocrine disorders (strong light can cause irritation) ŸUse of anticoagulants ŸEpilepsy...

 Open the catalog to page 14
Diode laser TEC Cooling 50 million shots-15

Chapter Three Clinical Operations Energy Density The energy density output (joules/cm²) is set by the operator during each treatment. Energy density is: the total energy (joules) output under the selected pulse type / the spot area (cm²). When the spot is smaller (12X15mm), the scattering is the smallest, so the result is a continuous energy output and deeper penetration. The greater the energy density, the higher the temperature of the target tissue hair, surrounding tissues and epidermis. Before treatment The treatment parameters depend on the skin type, the color, type, density and depth of...

 Open the catalog to page 15

Archived catalogs

  1. Morpheus8 RF-2

    32  Pages

  2. DL4

    6  Pages

  3. Miramhoo-HRL2

    6  Pages

  4. Miramhoo-DL5

    6  Pages

  5. Miramhoo-DL4

    6  Pages

  6. 22D HIFU-1

    9  Pages

  7. Shockwave ESWT

    19  Pages

  8. Skin analysis-1

    11  Pages

  9. Miramhoo-HL2

    5  Pages

  10. truSculpt ID

    6  Pages

*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.