Catalog excerpts

Fixed Restoration for Atrophic Ridges © MIS Implants Technologies Ltd. All rights reserved.
Open the catalog to page 1
MIS Warranty: MIS exercises great care and effort in maintaining the superior quality of its products. All MIS products are guaranteed to be free from defects in material and workmanship. However, should a customer find any fault in any MIS product after using it according to the directions, the defective product will be replaced.
Open the catalog to page 2
MIS Drilling Set for 18 and 20mm Length Implants. Implant Procedures. Solid Multi-Unit System. MULTIFIX Guide Strip.
Open the catalog to page 3
Overview. MIS MULTIFIX Fixed Restoration for Atrophic Ridges allows for a comprehensive treatment plan for edentulous patients, of full-arch immediate restoration, using Multi-Unit abutments on just four implants.
Open the catalog to page 4
Multi-Unit abutments and final fixed screw-retained restoration is immediately placed over the implants. The straight and 30° angulated Multi-Unit abutments allow for optimal distribution of force thanks to the unique insertion tool of the angulated units.
Open the catalog to page 5
Immediate Immediate esthetic and functional solution Permanent Permanent fixed full-arch restoration Stability High stability achieved by longer implants and posterior angulated placement Chair time Less chair time and more affordable treatment compared to full-arch alternatives Versatility Reduced need for bone augmentation, even in low bone volume cases
Open the catalog to page 7
18 and 20mm Length Implants. MIS SEVEN 18 or 20mm implants tilted posterior placement will provide high stability thanks to the anchorage in the dense D1 type anterior bone.
Open the catalog to page 8
9. MT-ETD38 Extra-long twist drill Ø3.80mm MT-ETD32 Extra-long twist drill Ø3.20mm MT-ETD28 Extra-long twist drill Ø2.80mm MIS Drilling Set for 18 and 20mm Length Implants. MT-ETD24 Extra-long twist drill Ø2.40mm MIS MULTIFIX Long Implants Drilling Set allows for a full drilling procedure followed by placement of an 18mm or 20mm Standard platform implant. Long implant placement is recommended for the posterior tilted implants when performing a Fixed Restoration for Atrophic Ridges. MT-LBT24 Long body try-in Ø2.40mm MT-LBT28 Long body try-in Ø2.80mm MT-LBT32 Long body try-in Ø3.20mm MT-LBT38...
Open the catalog to page 9
MIS unique single-use final drill is recommended only for dense bone. For soft bone, use the countersink drill.
Open the catalog to page 11
MT-BP460 Bone Profiler Ø4.60mm, internal hex., WP MT-BP370 Bone Profiler Ø3.70mm, internal hex., SP MT-BP320 Bone Profiler Ø3.20mm, internal hex., NP Bone Profiler Kit. Surgery may be followed by bone milling around the posterior tilted implants, for a uniform surface of the hard tissue, allowing an easy path of insertion and definite connection of the angulated Multi-Unit abutments. The MIS Bone Profiler Kit provides a solution for all platforms. MT-BGP32 Bone Profiler Guide Pin Ø3.20mm, internal hex., NP MT-BGP37 Bone Profiler Guide Pin Ø3.70mm, internal hex., SP MT-BGP46 Bone Profiler...
Open the catalog to page 12
Connect the Bone Profiler Guide Pin to the tilted implant (with max. torque of 10Ncm). Place the Bone Profiler over the Guide Pin while attached to the handpiece. Perform milling of the crestal bone (with a max. cutting speed of 200rpm) for a smooth path of insertion of the angulated Multi-Unit abutment.
Open the catalog to page 13
Solid Multi-Unit System. MIS Solid Multi-Unit abutments have no sharp edges for favorable soft tissue healing, a closed thread allowing for easy and preferable screw tightening and ultimate distribution of force and are delivered sterile for better surgical results. Straight Multi-Unit abutment Angulated Multi-Unit abutment
Open the catalog to page 14
Procedure. After using the MIS MULTIFIX Bone Profiler, connect the angulated Multi-Unit abutment to the tilted implant with its unique insertion tool and tighten the screw up to 20Ncm. Straight Multi-Unit long ratchet key (MT-MURL2) Straight Multi-Unit short ratchet key (MT-MURS2) Straight Multi-Unit long motor key (MT-MUML2) Straight Multi-Unit short motor key (MT-MUMS2) Long driver for 0.05 inch hex (MT-RDL30) Short driver for 0.05 inch hex (MT-RDS30) Long motor adapter for 0.05 inch hex (MT-LM005) Short motor adapter for 0.05 inch hex (MT-SM005)
Open the catalog to page 15
Bone Profiler Solid Multi-Unit 3. Bone Profiler Guide Pin All rights reserved. No part of this publication may be reproduced, transcribed, stored in an electronic retrieval system, translated into any language or computer language, or be transmitted in any form whatsoever, without the prior written consent of the publisher. Warning: MIS products referred to in this document should be used by licensed dentists only.
Open the catalog to page 16
Summary. 1. Drilling for the tilted implant is performed anterior to the mental foramen 2. 18 or 20mm implant is placed 3. MIS Bone Profiler Guide Pin is connected to the tilted implant 4. Bone milling by MIS Bone Profiler is performed 5. MIS angulated Multi-Unit abutment is connected after achieving a smooth path of insertion.
Open the catalog to page 17
MULTIFIX guide strips are used to assist in evaluating the drilling angle, while preparing the insertion site of the tilted implants during the MIS MULTIFIX procedure. These flexible strips are reusable. For use, a hole must be drilled in the front and center bone of the lower or upper jaw with a pilot drill at a 10mm depth. Once the guide strip pin is in place within this hole, it may be bent around the contours of the gingiva, its markings visible, showing guidelines for the drilling angle. This is in order to prevent drilling at an angle greater than 45”. MULTIFIX guide strips are...
Open the catalog to page 18
The MIS Quality System complies with the following international quality standards: ISO 13485:2003 - Quality Management System for Medical Devices, ISO 9001: 2008 – Quality Management System and CE Directive for Medical Devices 93/42/EEC. Please note that not all products are registered or available in every country or region.
Open the catalog to page 20All MIS Implants Technologies Ltd. catalogs and technical brochures
-
V3
6 Pages
-
C1
6 Pages
-
MIS_SEVEN
2 Pages
-
A Conical Connection Implant
32 Pages
-
PROSTHETIC OPTIONS
56 Pages
-
MIS_M4
2 Pages
-
_Conical_Connection_Catalog_2017
32 Pages
-
Internal_Hex_Catalog
224 Pages