Introduction
Miura boilers are designed to maximize efficiency and provide cost savings for hospitals. They offer high-pressure steam solutions with quick start-up times and low emissions, making them ideal for healthcare facilities.

Specifications and Features
Miura offers both the EX Series (gas or oil-fired) and the LX Series (gas-fired/low NOx) high-pressure steam boilers. These boilers are compact, fitting through standard doorways, and feature low NOx emissions, with ratings as low as 9ppm depending on the model. They are available in various pressure options and can operate on multiple fuel types.

Efficiency and Cost Savings
Miura boilers are engineered for high in-service efficiency, achieving fuel-to-steam efficiencies of 85%. They offer significant fuel savings compared to traditional firetube designs, with studies showing 10% to 40% savings. The modular design allows for load matching and reduced installed horsepower, contributing to lower operational costs.

Environmental and Economic Benefits
Miura boilers support environmental sustainability by reducing CO2 emissions and conserving natural resources. Their compact design reduces construction costs, which is crucial for hospital facilities where space and budget are limited.

Operational Advantages
The boilers feature a quick start-up time of five minutes, allowing for efficient load management and reduced fuel consumption. The MI Controller automates boiler operation, ensuring even wear and efficient performance across all units.

Maintenance and Support
Miura provides an online maintenance system that records and diagnoses issues before they occur, ensuring reliable performance. The BL Micro Controller offers user-friendly monitoring and control of boiler operations.

Conclusion
Miura boilers offer hospitals a reliable, efficient, and environmentally friendly solution for steam generation. Their innovative design and technology provide significant cost savings and operational benefits, making them a preferred choice for healthcare facilities.
See more

Catalog excerpts

Hospital Brochure-1

More Hospitals are Discovering ” The Miura ” “ Advantage. MIURA Gas or Oil Fired EX Series High Pressure Steam Boiler MIURA Gas-Fired/Low Nox LX Series High Pressure Steam Boiler “ We had Miura boilers here for about three years. Our first two paid for themselves in about a year on fuel savings alone. These were Miura EX-Series duel-fuel 200BHP units.The third unit is an LX-Series gas-fired 100BHP unit.” Shannon Clifton, Engineering Supervisor, Duke Raleigh Hospital

 Open the catalog to page 1
Hospital Brochure-2

Hospitals Select Miura Boilers for Highest Natural Resource Conservation, Reduc Seasonal Efficiency Miura boilers maximize efficiency for the unique seasonal load requirements of hospitals, while providing the 100% back-up capability (N+l) as required by the Joint Commission (JCAHO). For example, a typical competitor may spec two 400BHP units for a mid size hospital, while Miura will spec three 200BHP units.The competitor will run both units (800HP) while Miura will run two 200HP units (400HP) and have the third 200HP unit on standby. Since Miura boilers produce steam in 5 minutes from a cold...

 Open the catalog to page 2
Hospital Brochure-3

Efficiency in All Seasons, Fuel Cost Savings, ed Construction Spending, and more... High and low pressure steam options available (300 MAWP, Hot water boilers are available depending on models (refer to a Miura hot water boiler catalog fit through a standard doorway The BL Micro Green (normal) Controller Boiler Control System your boiler in an easy- to-read, user-friendly • Steam Pressure • Feed Water • Scale Monitor • Overheat Monitor • Flame Current • Remaining Time • Automatic Surface Valve (On/Off) • Water Conductivity Management Data Greater control over steam pressure settings for steadier...

 Open the catalog to page 3
Hospital Brochure-4

Are your boilers burning your bottom line? Copy, fill out, and fax-back today for a Free In-Service Efficiency Study. Company Name: Contact Name: Company Address: Phone Number: ( Email Address: Please check all that apply: □ I am interested in a free in-service efficiency study □ I am interested in a free load analysis □ Please cotact me with more information on Miura Boiler, Ine In-Service Efficiency is a measure of overall performance, no matter your load profile. High In-Service Efficiency is the level of performance every Miura Boiler customer can expect.This standard of excellence has been...

 Open the catalog to page 4

All Miura Boiler catalogs and technical brochures

  1. Steam Boilers

    6  Pages

  2. Colormetry

    4  Pages

  3. BOILERMATE

    2  Pages

  4. Think Green

    4  Pages

  5. MMP+ MMP

    4  Pages

  6. MMC MMIP

    4  Pages

  7. MMRC MMRP

    4  Pages

  8. Steam Boilers

    6  Pages

  9. New LX-300

    2  Pages

  10. MI System

    4  Pages

*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.