video corpo

Steam Boilers
6Pages

{{requestButtons}}

Catalog excerpts

Steam Boilers - 1

The new BL Micro Controller Boiler Control System (left), the “brain” behind Miura’s enhanced energy management system, offers signicant advancements including many new individual monitoring points –an increase of over 60% compared to our popular XJ1 Controller. The BL Controller provides robust 24/7 boiler Monitoring, Measuring & Verication (MM&V) capabilities and enhances troubleshooting by identifying problems and suggesting solutions via an easy-to-read display that interfaces with Miura Online Maintenance® software. Information is accessible both on site and on-line. The BL Controller features simple, intuitive programming that is easy to set up, program and operate. When combined with our O&M training program, the easy-to-use interface provides your facility with an intelligent boiler system to optimize energy and personnel management for increased productivity, efciency and a reduced environmental impact. ITEM Utilization Horsepower Equivalent Output (*2) Heat Output • Allows for compensated adjustment of high and low re scale thermocouple settings. • Allows for compensated adjustment of automatic blowdown based upon Total Dissolved Solids (TDS) and/or blowdown rates. Steam Pressure Flue Gas Temperature Feed Water Temperature Scale Monitor Temperature Overheat Monitor Temperature Flame Current Remaining Time to Blowdown Automatic Surface Blowdown Valve (On/Off) Water Conductivity 11-Point Boiler Management Data ... Plus many more EX-200 SGO EX-250 SGO EX-300 SGO (*9, *10) 150HP 200HP 250HP 300HP 3,450 LB/HR 5,175 LB/HR 6,900 LB/HR 8,625 LB/HR 10,350 LB/HR 3,348,000 BTU/HR 5,022,000 BTU/HR 6,695,000 BTU/HR 8,369,000 BTU/HR 10,050,000 BTU/HR 193 FT2 323 FT2 170 PSIG MAWP, 150 PSIG Maximum Operating Efciency (fuel to steam) (*3) Heating Surface Area 85% (80% without Economizer) 323 FT2 407 FT2 468 FT2 Operational Weight 7,250 LBS 11,500 LBS 11,500 LBS 17,850 LBS 18,000 LBS Shipping Weight 6,750 LBS 10,650 LBS 10,650 LBS 16,600 LBS 17,100 LBS Dimensions Given are Approximate Width 81 1⁄2 in. 90 in. 90 in. 94 in. 1051⁄2 in. Length 108 ⁄ in. 130 in. 130 in. 135 ⁄ in. 142 in. Height 102 1⁄2 in. 127 in. 127 in. 157 in. 157 in. 12 Combustion System Electric Spark Ignited, Interrupted Gas Pilot Power Supply Max. Electrical Consumption 208, 230, 460, or 575 V, 3 PHASE, 60 HZ 13.35 KVA (14.2 for oil) 24.5 KVA (25.4 for oil) 27.5 KVA (28.5 for oil) 32.3 KVA (34.3 for oil) Fuel Type (*4) Gas Consumption (*5) No. 2 oil 12 Proprietary Forced Draft, Step Fired Modulation Hi-Low-Off Ignition System The BL Micro Controller Boiler Control System measures the performance of your boiler in an easy-to-read, user-friendly format: • • • • • • • • • • EX-150 SGO 100HP Maximum Pressure (*1) High Performance via Enhanced Control Capability • Greater control over steam pressure settings for steadier steam pressure. EX-100 SGO 35.4 KVA (37.3 for oil) Natural Gas or Propane (3-5 PSIG), No. 2 oil 3,920 SCFH 5,880 SCFH 28.1 GAL/Hr 42.2 GAL/Hr Gas Supply Pressure 7,850 SCFH 9,810 SCFH 11,780 SCFH 68.7 GAL/Hr 56.3 GAL/Hr 84.5 GAL/Hr 3-5 PSIG Natural (Gas or Propane) OmegaFlo w Flow of combustion gas Dual Fuel (Gas/Oil) Miura’s EX Series boilers offer a unique advantage for users of both gas and oil. Now you can enjoy the exibility of switching fuel, without the need for a separate burner, typically required by other manufacturers. Miura technology means outstanding innovation and ease of use. Reduced Boiler Footprint Miura’s unique compact modular design utilizes a low volume pressure vessel offering output capacities comparable to much larger conventional boilers. The resulting reduced boiler footprint provides design exibility, reduced construction costs and enhanced utilization of existing space. Built-in Online Monitoring 2 in. 3 in. 3 in. 4 in. 4 in. One 2 in. One 2 1⁄2 in. One 2 1⁄2 in. Two 2 in. Two 2 1⁄2 in. Main Water Inlet 1 in. 1 in. 1 in. 1 1⁄4 in. 1 1⁄4 in. Fuel Gas Inlet 2 in. 2 in. 2 in. 2 ⁄ in. 2 1⁄2 in. Automatic Surface Blowdown 38 One ⁄ in. One ⁄ in. 38 One ⁄ in. Two 3⁄8 in. Two 3⁄8 in. Manual Blowdown • Easily interfaces with the Miura ‘‘Colormetry’’ unit to minimize scale formation due to water softener failure. Main Steam Outlet Safety Valve Outlet (*1) Two 1 in. Two 1 in. Two 1 in. Two 1 in. Two 1 in. Chimney Diameter (ID) 14 in. 20 in. 20 in. 20 in. 26 in. Fuel Oil Inlet See Miura’s MOM / ER brochure for more information. ⁄ in. 34 38 Flame Detector Ultraviolet Flame Eye Sensor Pressure Control Miura’s MOM / ER “Dashboard” Systems Efciency is also measured in consistent, reliable performance and Miura offers a robust suite of “dashboard” monitoring systems integrated with its BL boiler controller to provide real-time, 24/7 monitoring capability. Miura’s On-line Maintenance® (“MOM”) system provides a unique“sliding window” feature that records cautions / alarms in real time + 4 seconds preceding them to provide enhanced troubleshooting capability. The “MOM” system is standard with every unit and Miura offers monitoring to subscribing customers with a free 6-month trial of the service. Miura offers its ER monitoring system to those facilities that wish to integrate boiler monitoring into their on-site control system rather than subscribe to an off-site monitoring service. 12 Adjustable Pressure Transducer and Switch Liquid Volume Control Overheat Protection Note: *1 *2 *3 *4 *5 *6 *7 *8 *9 *10 *11 Electric Conductivity Type Low Water Cut Off & Thermocouple Optional EXH-SGO Series at 250 PSIG MAWP, 225 PSIG maximum operating. Equivalent output calculated from and at 212°F (100°C) feed water at 212°F (100°C) steam. Thermal Efciencies are based on high heating values of fuels at 68°F (20°C) feed water. UL and c-UL approved for natural gas, propane, and No. 2 oil. Gas consumption based on natural gas with high heating 1004 BTU/SCF. All Miura steam boilers are fully packaged and test red at factory. Built to meet and exceed UL & ASME standards in U.S.A; c-UL & B-51 standards in Canada. Flue gas recirculation is optional only with the Economizer. Low water content option available to meet provincial water volume regulations in Canada. Low NOx model (EXN300SGOF) available to meet 30ppm NOx. Safety valve outlet size may change depending on the pressure setting. ‘‘S’’ - Economizer ‘‘G’’ - Natural Gas or Propane Fired ‘‘O’’ - #2 Oil Fired The new, BL Micro Controller Boiler Control System Miura Gas/Oil-Fired EX Series High Pressure Steam Boiler USA: 1-888-309-5574 • Canada: 1-800-666-2182 • www.miuraboiler.com Worldwide Headquarters • Japan: +81-89-979-7123 • www.miuraz.co.jp Facilities located in: USA • Canada • Japan • China • Korea • Taiwan Miura Steam is Engineered for Greater Efciency, Lower Costs, and Reduced Environmental Impact. EX1EN10 On-Demand Steam Solutions

Open the catalog to page 1

All Miura Boiler catalogs and technical brochures

  1. Colormetry

    4 Pages

  2. BOILERMATE

    2 Pages

  3. Think Green

    4 Pages

  4. MMP+ MMP

    4 Pages

  5. MMC MMIP

    4 Pages

  6. MMRC MMRP

    4 Pages

  7. New LX-300

    2 Pages

  8. MI System

    4 Pages