A simple yet powerful daily QA test to verify IGRT setup accuracy The QUASAR™ IsoCenter Cube is designed to implement a modified Winston-Lutz test for IGRT accuracy required for optimal treatment delivery. This system is also used for TG-142 quality assurance compliance for isocenter and laser alignment tests. End-to-end positioning accuracy from planning CT to clinical IGRT treatment setup is achieved with 0.1 mm precision and is accomplished in minutes. The test is performed by aligning the QUASAR™ IsoCenter Cube Phantom using the cross-hairs etched on each side with your IGRT system, Compatible with TG142 tests Check various beam shaping devices Analyze EPID radiation field exposures Quick and simple Winston-Lutz testing for IGRT accuracy Report left/right, superior/inferior and anterior/posterior errors at configurable gantry, collimator and table angles then capturing radiation field exposures with film or EPID. The test results are used to determine end-to-end accuracy for frameless SRS, SBRT, and IGRT treatments. The QUASAR™ IsoCenter Cube Phantom features a seamless acrylic 5 x 5 x 5 cm unibody enclosure containing one 6 mm diameter Tungsten Sphere located at the central axis of the main cross-hairs and used for measuring isocenter accuracy. Displayed on 3 faces are 3 mm offset laser alignment marks, which are used for couch position accuracy. Test end-to-end IGRT positioning accuracy for clinical treatment setups with 0.1 mm precision in less than 5 minutes. Perform test by aligning the phantom containing radiopaque sphere with IGRT system, then capturing radiation field exposures with film or EPID Use the test results to determine end-to-end accuracy for frameless SRS, SBRT, and IGRT treatments Above: The acrylic 5 x 5 x 5 cm QUASAR™ IsoCenter Cube Phantom used for measuring i

 Open the catalog to page 1
Modus QA - Product Data Sheet - IsoCenter Cube-2

WINSTON-LUTZ ANALYSIS SOFTWARE Analyze EPID radiation field exposures with the automated Analysis Software. Check various beam shaping devices, report left/right, superior/ inferior and anterior/posterior errors at configurable gantry, collimator and table angles. Ability to test IGRT accuracy with a minimum of two gantry angle images. The user sets the warning and fail levels, and can visually see pass (green), warning (yellow), and fail (red) results. Above: Screenshot of the QUASAR™ IsoCenter Cube analysis software displaying pass (green) results Above: Screenshot of the QUASAR™ IsoCenter...

 Open the catalog to page 2
*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.