QUASAR IsoCenter Cube

QUASAR IsoCenter Cube

QUASAR IsoCenter Cube

Product catalog summary
Key Benefits
  • Facilitates quick and simple Winston-Lutz testing for Image-Guided Radiation Therapy (IGRT) accuracy.
  • Minimizes Cone Beam Computed Tomography (CBCT) artifacts.
  • Analyzes Electronic Portal Imaging Device (EPID) radiation field exposures and various shaping devices.
  • Reports positional errors in multiple directions at configurable gantry, collimator, and table angles.
Product Overview

The QUASAR™ IsoCenter Cube is designed to enhance IGRT accuracy through a modified Winston-Lutz test. It ensures precise end-to-end IGRT positioning accuracy for clinical treatment setups with a precision of 0.1 mm in under 5 minutes. The process involves aligning a phantom with a radiopaque sphere using the IGRT system and capturing radiation field exposures with film or EPID.

Analysis Software
  • Imports and analyzes EPID images.
  • Configures gantry, collimator, and couch rotation parameters.
  • Exports results for trend analysis.
  • Defines parameter and threshold templates.
Specifications
  • Acrylic cube dimensions: 5 x 5 x 5 cm.
  • Tungsten sphere at isocenter with a 6mm diameter.
  • Rubber no-slip base and laser alignment marks on the cube.
  • Offset laser alignment marks on three faces.
Minimum Technical Requirements
  • Standard desktop or laptop PC with Windows 7, Vista, or XP.
  • 1 GB RAM.
  • .NET framework 4.0.
Ordering Information

Product Code: 100-1016 QUASAR™ IsoCenter Cube Package (includes Phantom and Software).

Contact Information

Toll-Free: (866) 862-9682 (North America)
Phone: +1 (519) 438-2409
Fax: +1 (519) 643-0127
Email: [email protected]
Website: www.modusmed.com

QUASAR™ in Radiation Therapy

The QUASAR™ system supports testing of various dosimetric and nondosimetric functions in planning systems, CT simulators, and delivery systems. It is integral to quality assurance programs, aiding in respiratory motion, MLC beam geometry, and daily on-board imaging QA. It is also useful for commissioning new systems, upgrades, and testing repairs, ensuring optimal patient treatment.

See more

Catalog excerpts

QUASAR IsoCenter Cube-1

Verify IGRT setup accuracy in less than 5 minutes IsoCenter Cube KEY BENEFITS ± ± ± ± ± Quick simple Winston-Lutz testing for IGRT accuracy Minimize CBCT artifacts Software Analyze EPID radiation field exposures Analyze various shaping devices Report left/right, superior/inferior and anterior/posterior errors at configurable gantry, collimator and table angles The QUASAR™ IsoCenter Cube is designed to provide information needed to clinically implement a modified Winston-Lutz test for IGRT accuracy. Test end-to-end IGRT positioning accuracy for clinical treatment setups with 0.1 mm precision in less than 5 minutes. The test is performed by aligning a phantom containing radiopaque sphere with IGRT system, then capturing radiation field exposures with film or EPID. The test results are used to determine end-to-end accuracy for frameless SRS, SBRT, and IGRT treatments. Analyze IsoCenter Cube’s Winston-Lutz images with the IsoCenter Cube Software. ANALYSIS SOFTWARE ± Import and analyze EPID images ± Configure gantry collimator and couch rotation parameters ± Export results for trending purposes ± Define parameter and threshold templates Accuracy. Confidence. Specifications subject to change without notice and shall not be liable for any errors or omissions contained in this document. © 2012 Modus Medical Devices Inc. PDS100-1016, 10/12

 Open the catalog to page 1
QUASAR IsoCenter Cube-2

Accuracy. Confidence. QUASAR™ in Radiation Therapy The Quality Assurance System for Advanced Radiotherapy (QUASAR™) supports the testing of a wide variety of dosimetric and nondosimetric functions of planning systems, CT simulators and delivery systems. QUASAR™ is a valuable part of any quality assurance program. From respiratory motion and MLC beam geometry to daily on-board imaging QA, QUASAR™ phantoms and software are ready to be incorporated into your QA protocols for regularly scheduled testing. They are also effective for commissioning new systems and upgrades, and testing repairs. Designed...

 Open the catalog to page 2
*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.