PRODUCT SPECIFICATIONS • • • • • Phantom Material: Acrylic Density: 1.18 g/cm³ Weight: 16.8 kg (compared to 40 - 80 kg for solid grid phantoms) Volume Susceptibility: χv= -9.01 x 10-6 @ 20°C Contrast Media: 5 liters of high T1 contrast Paraffinic Mineral Oil Volume Susceptibility: χv= -9.24 x 10-6 @ 20°C Density: 0.83 g/cm³, T1= ~300ms @1.5T, Dielectric Constant εr <3 Physical Dimensions: 38.1 cm diameter by 34 cm long Imaging Dimensions: 36.8 cm diameter by 32.1 cm long Internal Volume: hollow, 33 cm diameter x 28.8 cm long, ~25 liters MRID3D DISTORTION ANALYSIS SYSTEM MRI DATA ACQUISTION REQUIREMENTS • 3D T1 weighted sequence (GE-FLASH or LAVA, Philips-Fast Field Echo, SIEMENS-VIBE) with 1 NEX, minimum TE and TR, 10 minute acquisition time @ 1.5T, ~5 minute acquisition time @ 3T ~ • A 40 cm maximum Field of View (FOV) acquired in one continuous Z slab to ensure all control points are located • 1mm3 Isotropic (cubic) voxels • Bandwidth Range: 100 Hz / Pixel to 1,000 Hz / Pixel (25KHz to 250 KHz) RECOMMENDED SYSTEM REQUIREMENTS • • • • • • Operating System: Windows 7 or higher Processor: Intel Core™ i7 or better Hard Disk Space: 10 GB minimum (64-bit) RAM: 8 gigabyte (GB) or more Screen Resolution: 1280 x 720 pixels or higher Graphics Card: Intel HD Integrated Graphics or Nvidia GeForce GTX 750 or better QUASAR™ MRID3D Geometric Distortion Analysis System Includes: • 1-Software License • 1-Phantom • User’s guide Additional Software License Annual Maintenance Contract Extended Hardware Warranty Modus QA 1570 North Routledge Park, London, Ontario Canada N6H 5L6 Toll Free: (866) 862-9682 Phone: +1 (519) 438-2409 Fax: +1 (519) 643-0127 info@modusQA.com www.modusQA.com © 2015 Modus Medical Devices Inc. All Rights Reserved. Specifications subject to change without notice. Modus is not responsible for errors or omissions. Modus makes no warranties or commitments concerning the availability of future products or versions that may be planned or under development. PDS#100-1018, REV#05/28 • Light Weight • Fast Scan Times • Feature Rich Analysis • Powerful 3D Viewer Quantify Magnetic Resonance Image disto

Open the catalog to page 1
QUASAR™ MRID3D - 2

QUASAR™ MRID3D is a new, patent pending, cost-effective QA system for quantifying geometric distortion in 3D MR images. Analysis is performed on images for diagnostic and guidance applications. Unlike other distortion analysis products, which only sample a few imaging planes, QUASAR™ MRID3D analyzes the entire 3D field of view in a single acquisition. A publication in Medical Physics is available online: http://dx.doi.org/10.1118/1.4898582. The results have been verified by comparison to a custom high density 3D grid phantom. Novel method based on 3D harmonic analysis of distortion •...

Open the catalog to page 2

All Modus Medical Devices catalogs and technical brochures

  1. QUASAR? eQA

    2 Pages

  2. QUASAR ADQ

    2 Pages