Brochure

Brochure
1 / 16 PagesView full catalog

Brochure

Product catalog summary
Introduction
Moor Instruments has developed laser Doppler imaging (LDI) technology to enhance the early and accurate assessment of burn wounds. This technology has been refined over 20 years with input from burn surgeons globally and is backed by international clinical trials.

Challenges in Burn Assessment
Accurate diagnosis of burn severity is difficult. LDI addresses this by mapping skin blood flow, which correlates with healing potential. Studies indicate LDI has a 97% accuracy rate compared to 60-80% for traditional methods.

Benefits of Laser Doppler Imaging
  • For Burn Care Staff: Reduces workload, avoids unnecessary surgeries, and improves wound management.
  • For Financial Administration: Demonstrates cost savings and clinical benefits, as supported by NICE guidelines.
  • For Patients: Enables prompt treatment, reduces hospital stay, and improves cosmetic outcomes.
  • For Researchers: Provides accurate burn assessments, facilitating meaningful treatment comparisons.


Features of Moor Laser Doppler Systems
Moor offers comprehensive packages including imagers, software, and training. Key features include:
  • Non-contact imaging for pain-free assessment.
  • Instant results for prompt treatment planning.
  • Large area imaging capabilities.
  • CE marked devices with FDA clearances.


Case Studies
Several case studies demonstrate the effectiveness of LDI in assessing burn wounds in pediatric patients, showing improved healing outcomes and reduced need for surgery.

Frequently Asked Questions
  • When to Scan: Reliable imaging is possible from 48 hours post-injury.
  • Scan Duration: Typically 1.5 minutes for moorLDI2-BI and 4 seconds for moorLDLS-BI.
  • Accuracy: LDI accuracy exceeds 95% when combined with clinical evaluation.
  • Software Usability: Designed to be user-friendly with comprehensive training provided.
Device Usage
The moorLDI2-BI and moorLDLS-BI scanners are fully mobile and can be used in various hospital environments, including operating rooms, patient rooms, burn treatment rooms, and clinical examination rooms.

Blood Flow Imaging
Normal, unburned skin may appear similar to deeper wounds in blood flow images due to low skin blood flow at uninjured sites. Visual and clinical assessments are essential for accurate interpretation of moorLDI images.

Research and Validation
Several studies have validated the effectiveness of laser Doppler imaging (LDI) in burn assessment. LDI has been shown to improve clinical assessment accuracy, predict burn wound outcomes, and guide treatment decisions. It is particularly effective in pediatric populations and can predict healing potential and the risk of hypertrophic scarring.

Accuracy and Performance
LDI has demonstrated high accuracy in burn depth assessment, with accuracies improving over time post-burn. It is more accurate than traditional clinical methods and is recommended for all burns of indeterminate depth.

Technical Specifications
The devices use laser Doppler imaging with visible red and near-infrared laser sources. They are classified as Class 3R laser products per IEC standards. The devices are certified to ISO 13485:2016 and have CE marking and FDA 510(k) clearances.

Operating Conditions
The devices operate within a temperature range of 15-30°C and require normal ambient lighting. They are equipped with a touchscreen medical-grade panel PC and Windows-based software for control and analysis.

Conclusion
Moor Instruments' laser Doppler imaging devices are reliable tools for burn assessment, offering high accuracy and aiding in clinical decision-making. They are supported by extensive research and meet international safety and quality standards.
See more

Catalog excerpts

Brochure-1

Early and Accurate Burn Assessment with Laser Doppler Imaging innovation in microvascular assessment

 Open the catalog to page 1
Brochure-2

About Us Moor has consulted with burns surgeons worldwide for over 20 years to develop laser Doppler imaging as a powerful aid to burn wound assessment. Working with clinicians we have been involved with international, multi-centre clinical trials for the assessment of burns using Moor laser Doppler imagers. If you are using laser Doppler or plan to do so, we can help you with imager selection and provide technical information, competence based training and comprehensive support. moorLDI2-BI image – in use in theatre (reproduced with kind permission of the Burn Centre, University Hospital Ghent,...

 Open the catalog to page 2
Brochure-3

The Challenge of Early Burn Assessment... Accurately diagnosing the severity of burns has always been difficult, even for experienced clinicians. Moor offers a solution by providing a choice of laser Doppler imagers to assist with your treatment decisions. Our imagers assess and map skin blood flow - clinically proven to relate closely to the healing potential of burn injuries. “The use of diagnostic aids such as laser Doppler imaging (LDI) and formal review after 48 h to assess healing potential is key to ensuring appropriate treatment.” Kishikova L., Smith M.D., Cubison T.C.S. 2014. Evidence...

 Open the catalog to page 3
Brochure-4

Benefits for Patients and Staff using Moor Laser Doppler Imaging for Burn Assessment Benefits for Burn Care Staff Benefits for Financial Administration Earlier and more accurate burn assessments lead to a reduction in work-load. Accurate assessment Hospitals, insurances and reimbursements vary widely of clinically indeterminate burns avoids unnecessary within each continent and even within each country. surgery and avoids unnecessary delays where surgery is required. Early, appropriate wound management can With the NICE review (National Institute for Health and reduce the incidence of infection...

 Open the catalog to page 4
Brochure-5

Early and accurate burn assessment enables prompt and appropriate treatment with a consequent reduction in length of stay and better cosmetic outcomes. For wounds that appear deep by clinical assessment but are shown to be more superficial by Moor laser Doppler, unnecessary surgery, scarring and pain of a donor site can be avoided. This enables an earlier return to family, education or work. First-hand experience of laser Doppler at Moor Instruments dates back to 1978 and we have a wealth of experience in many research areas including burns. Many applications can take advantage of the speed,...

 Open the catalog to page 5
Brochure-6

Whichever Moor system you choose, we offer the complete package including imager, clinical mobile stand, touch screen panel PC kit with dedicated software and on going support and servicing. A vital part of the package is the installation and certified competence based training course which has been refined with direct clinical experience. Documentation provided includes an extensive Burn Atlas together with course notes. You will also be invited to join The Moor Burn Forum putting you in direct contact with a rapidly growing user group, who can share practical experience and measurement tips....

 Open the catalog to page 6
Brochure-7

Laser light penetrates the skin and is scattered by tissue and by moving blood cells in capillaries, arterioles and venules. The moving blood cells in the tissue cause Doppler frequency shifts, which are processed to produce a colour coded map of flow across the skin. A digital camera records a colour clinical photograph at the same time, corresponding closely with the blood flow image in size and aspect. The measurement is non contact and can quantify differences in flow over an area of tissue. There are two main modalities with unique advantages for adult and paediatric burns; Single point...

 Open the catalog to page 7
Brochure-8

Case Study 1 - Paediatric Hand Time Post Burn: Burn Cause: contact - other Healing Potential: Healing Potential: Healing Potential: more than 21 days less than 14 days Blood flow within burn area Clinical Assessment Initially assessed clinically on admittance as 2nd degree, <1% TBSA. At 5 days post burn the wound was clinically reviewed and the decision taken to apply a split skin graft, however the patient was unwell for theatre, and was not grafted. moorLDLS-BI Assessment Day 2 Wound mainly red indicating healing potential less than 14 days. Follow Up 9 Days Post Burn Dorsum of hand - central...

 Open the catalog to page 8
Brochure-9

Date Of Birth: Burn Cause: Time Post Burn: Scan Size (WxH): Healing Potential: ■ Healing Potential: I Healing Potential: more than 21 days I 14 to 21 days I less than 14 days Blood flow within burn area Clinical Assessment Day 3 Lund and Browder chart records initial clinical opinion for surgical treatment of abdomen and both thighs. The regions appear deep 2nd degree and full thickness. moorLDI2-BI shows high flow (HP14) on the abdomen and right thigh (except for a few regions of * slightly lower flow, HP14-21) indicating a good healing potential. The left thigh shows low flow (HP>21) within...

 Open the catalog to page 9
Brochure-10

Case Study 3 - Paediatric Chest Time Post Burn: Burn Cause: scald - water/drink Healing Potential: Healing Potential: Healing Potential: more than 21 days less than 14 days Blood flow within burn area Clinical Assessment A scald to a paediatric caused by hot water/drink. Initial clinical assessment, prior to moorLDI2-BI scan, diagnosed mainly deep 2nd degree burn wounds. moorLDI2-BI Report moorLDI2-BI image of wounds predicts most will heal within 14 days (red and associated areas of pink on the scan). Yellow areas will take longer to heal but should heal within 21 days. Outcome Almost complete...

 Open the catalog to page 10
Brochure-11

Frequently Asked Questions Answers (A) are only a summary. Users should consult the years and have designed and developed the software to appropriate user manual for full information. be very user friendly. Full training and support is provided for all users. Q. When should scanning be performed? A. Evidence from our clinical trial suggests that the earliest Q. What is the largest area you can image with reliable time for imaging is at least 48 hours after the injury, moor laser Doppler imagers? as burn wounds can change rapidly in the first 48 hours A. The image area is dependent on the scan...

 Open the catalog to page 11

All Moor Instruments catalogs and technical brochures

  1. MOORO2FLO-2

    4  Pages

*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.
About MedicalExpo
MedicalExpo is a marketplace that offers B2B players a complete experience, from product sourcing to purchase. MedicalExpo is an entity of VirtualExpo Group.