1. Catalogs
  2. Moor Instruments
  3. Full-fi eld, video frame rate blood fl ow imaging with moorFLPI-2

Full-fi eld, video frame rate blood fl ow imaging with moorFLPI-2

Full-fi eld, video frame rate blood fl ow imaging with moorFLPI-2

Full-fi eld, video frame rate blood fl ow imaging with moorFLPI-2

Product catalog summary
Specifications:
The moorFLPI-2 by Moor Instruments is a CE-marked medical device certified to ISO 13485:2016, utilizing laser speckle contrast analysis (LASCA) for blood flow imaging. It features a near-infrared laser diode (785nm) and red laser diodes (650nm), classified as Class 1 per IEC 60825-1:2014, ensuring safety without eye protection. The device is factory calibrated, offering image sizes from 6mm x 8mm to 225mm x 300mm with a motorized zoom lens. It has a camera resolution of 2064 x 1544 and an acquisition rate ranging from 100 images per second to 1 image every 12 hours. The device supports single point, single image, and video modes, with a pixel resolution of 6,600,000 pixels per cm². Advanced software is included for image acquisition, processing, and analysis, with various stand options and PC connections available.
Applications and Software:
The moorFLPI-2 provides real-time, high-resolution blood flow images using a non-contact imaging technique. It captures dynamic changes in blood flow with a spatial resolution of 3.9 microns per pixel and video frame rates up to 100 frames per second. It is suitable for pre-clinical and clinical research applications in fields such as neuroscience, dermatology, oncology, pharmacology, plastic surgery, chemical toxicology, intraoperative measurements, and cardiovascular research. The software supports setup, measurement, protocol control, analysis, reporting, and exporting, with features like zoom, auto-focus, and event marking.
Measurement Principle:
The device uses laser speckle contrast imaging to assess blood flow by analyzing changes in the speckle pattern generated when tissue is illuminated by laser light. High blood flow results in a blurred pattern with reduced contrast, while low flow shows high contrast, allowing for tracking of fast transients and spatial variations.
Technical Advantages:
The moorFLPI-2 offers motorized zoom and auto-focus for flexible imaging of both small and large areas. It provides spatial and temporal measurement modes for optimal selection between image frame rate and spatial resolution. Its compact design and flexible stand options make it suitable for various experimental and clinical research settings.
Camera/Image Resolution: The device supports a maximum resolution of 2064 x 1544.
Image Acquisition Rate: It can acquire images at rates ranging from 100 images per second to 1 image every 12 hours.
Acquisition Modes: The system offers Single Point (16 channel), Single Image, and Video mode.
Optical Design: Features a motorized 10x optical zoom and autofocus, with a single camera and RGB illumination for matching color photos and blood flow images.
Measurement Algorithms: Utilizes temporal and spatial processing, including fixed and sliding window algorithms.
Pixel Resolution: Achieves a high resolution of 6,600,000 pixels per cm².
Software: Developed over 20 years, the software includes advanced image acquisition, processing, editing, functionality, and analysis.
Stand Options: Compatible with standard VESA mount for desktop stands, microstands, and clinical mobile stands, as well as photographic fittings for tripods.
PC Connections: Equipped with 1 x USB 3.0 port.
External Connections: Features a programmable trigger in/out function with BNC connections.
Warranty: Offers a 2-year warranty covering parts and labor, with enhanced service contracts available.
Weights/Dimensions: The scan head measures 23cm x 12cm x 25cm and weighs 2.3kg.
Power Supply: Supports universal voltage from 100V-230V, with acquisition rate unaffected by local electrical supply frequency.
Disclaimer: Moor Instruments reserves the right to change specifications without notice. The moorFLPI-2 is intended as a clinical research tool without specific diagnostic claims.
About Moor Instruments: Established in 1987, Moor Instruments is a leader in designing, manufacturing, and distributing monitoring and imaging systems for micro-vascular assessments, including tissue oxygenation assessments. The company prioritizes performance, quality, and service to ensure customer satisfaction and is involved in various development projects with partners and manufacturers.
See more

Catalog excerpts

Full-fi eld, video frame rate blood fl ow imaging with moorFLPI-2-1

About Moor Instruments Full-field, video frame rate blood flow imaging with moorFLPI-2 Moor Instruments, established in 1987, is a world leader in the design, manufacture and distribution of monitoring and imaging systems for micro-vascular assessments. We are proud now to include tissue oxygenation assessments within this portfolio. Firsthand experience of laser Doppler research and development within Moor dates back to 1978 and with this we have the breadth of knowledge to help with your application and the enthusiasm to try and find answers to any of your questions. By giving priority to performance, quality and service, we strive to ensure the highest levels of customer satisfaction. Our dedicated design team is involved with a number moorFLPI-2 with optional panel PC and MS3b mobile stand. of development projects for other partners and manufacturers. Whatever your needs, as a researcher, clinician or manufacturer, Moor will work harder for you. Pixel Resolution Highest resolution of 6,600,000 pixels per cm². Quality Control Moor Instruments is certified to ISO 13485: 2016. The moorFLPI-2 is CE marked as a medical device. Measurement Principle Laser speckle contrast analysis (also known as LASCA). Laser Safety Classification Near Infra-Red laser diode: 785nm. Aiming beams red laser diodes: 650nm. Class 1 per IEC 60825-1:2014. (Safe to use without eye protection). Software Refined over 20 years according to customer demands including advanced image acquisition, processing, editing, functionality and analysis. Stand Options Scan head has standard VESA mount for desktop stand, Microstand and Clinical Mobile stand. Photographic fitting for use with tripods, etc. CLASS 1 LASER PRODUCT Calibration Factory Calibrated. Image size 6mm x 8mm up to 225mm x 300mm (continuously variable with zoom lens). Camera/Image Resolution 2064 x 1544 maximum. Image Acquisition Rate 100 images per second to 1 image every 12 hours. Acquisition Modes Single Point (16 channel), Single Image and Video mode. Optical Design Motorised 10 x optical zoom and auto focus. Single camera / RGB illumination to match colour photo and blood flow images. PC Connections 1 x USB 3.0 port. External Connections Programmable trigger in / out function with BNC connections. Warranty 2 years, parts & labour, enhanced service contracts available. Weights/ Dimensions Scan head 23cm x 12cm x 25cm, Scan head 2.3kg. Power Supply Universal Voltage, 100V-230V. Note acquisition rate is unaffected by frequency of local electrical supply. Moor Instruments reserves the right to change specifications without notice. No specific diagnostic claims are made for the moorFLPI-2 so the performance analysis is intended to demonstrate that it represents a useful and effective clinical research tool, either in isolation or when combined with other measurement techniques. Measurement Algorithms Temporal and Spatial processing (including fixed and sliding window algorithms). innovation in microvascular assessment Moor Instruments Ltd Millwey Axminster Devon EX13 5HU UK tel +44 (0)1297 35715 fax +44 (0)1297 35716 email [email protected] Please visit www.moor.co.uk for full details of our international distributors and partners

 Open the catalog to page 1
Full-fi eld, video frame rate blood fl ow imaging with moorFLPI-2-2

moorFLPI-2 – Capturing high resolution blood flow images in real time The moorFLPI-2 blood flow imager uses the laser speckle contrast technique to deliver real-time, high-resolution blood flow images, providing outstanding performance in a wide range of applications. The laser speckle technique Applications and software Established pre-clinical and clinical research applications Report templates can be custom defined to produce the are wide-ranging; examples include; analysis and reporting that is needed from your studies from standard statistical and protocol reports (pressure The full-field laser...

 Open the catalog to page 2
Full-fi eld, video frame rate blood fl ow imaging with moorFLPI-2-3

moorFLPI-2 – Capturing high resolution blood flow images in real time The moorFLPI-2 blood flow imager uses the laser speckle contrast technique to deliver real-time, high-resolution blood flow images, providing outstanding performance in a wide range of applications. The laser speckle technique Applications and software Established pre-clinical and clinical research applications Report templates can be custom defined to produce the are wide-ranging; examples include; analysis and reporting that is needed from your studies from standard statistical and protocol reports (pressure The full-field laser...

 Open the catalog to page 3
Full-fi eld, video frame rate blood fl ow imaging with moorFLPI-2-4

About Moor Instruments Full-field, video frame rate blood flow imaging with moorFLPI-2 Moor Instruments, established in 1987, is a world leader in the design, manufacture and distribution of monitoring and imaging systems for micro-vascular assessments. We are proud now to include tissue oxygenation assessments within this portfolio. Firsthand experience of laser Doppler research and development within Moor dates back to 1978 and with this we have the breadth of knowledge to help with your application and the enthusiasm to try and find answers to any of your questions. By giving priority to performance,...

 Open the catalog to page 4

All Moor Instruments catalogs and technical brochures

  1. moorVMS-TREND

    4  Pages

  2. moorVMS-VASC

    4  Pages

*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.