Catalog excerpts

About Moor Instruments Full-field, video frame rate blood flow imaging with moorFLPI-2 Moor Instruments, established in 1987, is a world leader in the design, manufacture and distribution of monitoring and imaging systems for micro-vascular assessments. We are proud now to include tissue oxygenation assessments within this portfolio. Firsthand experience of laser Doppler research and development within Moor dates back to 1978 and with this we have the breadth of knowledge to help with your application and the enthusiasm to try and find answers to any of your questions. By giving priority to performance, quality and service, we strive to ensure the highest levels of customer satisfaction. Our dedicated design team is involved with a number moorFLPI-2 with optional panel PC and MS3b mobile stand. of development projects for other partners and manufacturers. Whatever your needs, as a researcher, clinician or manufacturer, Moor will work harder for you. Pixel Resolution Highest resolution of 6,600,000 pixels per cm². Quality Control Moor Instruments is certified to ISO 13485: 2016. The moorFLPI-2 is CE marked as a medical device. Measurement Principle Laser speckle contrast analysis (also known as LASCA). Laser Safety Classification Near Infra-Red laser diode: 785nm. Aiming beams red laser diodes: 650nm. Class 1 per IEC 60825-1:2014. (Safe to use without eye protection). Software Refined over 20 years according to customer demands including advanced image acquisition, processing, editing, functionality and analysis. Stand Options Scan head has standard VESA mount for desktop stand, Microstand and Clinical Mobile stand. Photographic fitting for use with tripods, etc. CLASS 1 LASER PRODUCT Calibration Factory Calibrated. Image size 6mm x 8mm up to 225mm x 300mm (continuously variable with zoom lens). Camera/Image Resolution 2064 x 1544 maximum. Image Acquisition Rate 100 images per second to 1 image every 12 hours. Acquisition Modes Single Point (16 channel), Single Image and Video mode. Optical Design Motorised 10 x optical zoom and auto focus. Single camera / RGB illumination to match colour photo and blood flow images. PC Connections 1 x USB 3.0 port. External Connections Programmable trigger in / out function with BNC connections. Warranty 2 years, parts & labour, enhanced service contracts available. Weights/ Dimensions Scan head 23cm x 12cm x 25cm, Scan head 2.3kg. Power Supply Universal Voltage, 100V-230V. Note acquisition rate is unaffected by frequency of local electrical supply. Moor Instruments reserves the right to change specifications without notice. No specific diagnostic claims are made for the moorFLPI-2 so the performance analysis is intended to demonstrate that it represents a useful and effective clinical research tool, either in isolation or when combined with other measurement techniques. Measurement Algorithms Temporal and Spatial processing (including fixed and sliding window algorithms). innovation in microvascular assessment Moor Instruments Ltd Millwey Axminster Devon EX13 5HU UK tel +44 (0)1297 35715 fax +44 (0)1297 35716 email sales@moor.co.uk Please visit www.moor.co.uk for full details of our international distributors and partners
Open the catalog to page 1
moorFLPI-2 – Capturing high resolution blood flow images in real time The moorFLPI-2 blood flow imager uses the laser speckle contrast technique to deliver real-time, high-resolution blood flow images, providing outstanding performance in a wide range of applications. The laser speckle technique Applications and software Established pre-clinical and clinical research applications Report templates can be custom defined to produce the are wide-ranging; examples include; analysis and reporting that is needed from your studies from standard statistical and protocol reports (pressure The full-field...
Open the catalog to page 2
moorFLPI-2 – Capturing high resolution blood flow images in real time The moorFLPI-2 blood flow imager uses the laser speckle contrast technique to deliver real-time, high-resolution blood flow images, providing outstanding performance in a wide range of applications. The laser speckle technique Applications and software Established pre-clinical and clinical research applications Report templates can be custom defined to produce the are wide-ranging; examples include; analysis and reporting that is needed from your studies from standard statistical and protocol reports (pressure The full-field...
Open the catalog to page 3
About Moor Instruments Full-field, video frame rate blood flow imaging with moorFLPI-2 Moor Instruments, established in 1987, is a world leader in the design, manufacture and distribution of monitoring and imaging systems for micro-vascular assessments. We are proud now to include tissue oxygenation assessments within this portfolio. Firsthand experience of laser Doppler research and development within Moor dates back to 1978 and with this we have the breadth of knowledge to help with your application and the enthusiasm to try and find answers to any of your questions. By giving priority to...
Open the catalog to page 4All Moor Instruments catalogs and technical brochures
-
moorVMS-TREND
4 Pages
-
moorVMS-OXY_Brochure
4 Pages
-
moorVMS-VASC
4 Pages
-
moorVMS-LDF_Brochure
4 Pages