MOORO2FLO-2

MOORO2FLO-2

MOORO2FLO-2

Product catalog summary
Introduction
The moorO2Flo-2 is an advanced imaging system by Moor Instruments Ltd, designed for simultaneous imaging of tissue perfusion and oxygenation using laser speckle contrast technology and reflectance spectroscopy.

Specifications
  • Quality Control: CE marked.
  • Measured Parameters: Tissue perfusion in PU, changes in oxygenated and deoxygenated haemoglobin in AU.
  • Working Distance: 100-380 mm.
  • Imaging Area: 8 x 6 mm to 300 x 200 mm.
  • Image Resolution: 2060 x 1540 for haemoglobin images; 2064 x 1544 for perfusion and color images.
  • Frame Rate: Up to 20 fps for combined imaging; up to 100 fps for perfusion only.
  • Operating Environment: Indoor use, 15-30°C, 86-106 kPa, 20-80% humidity.
  • Lighting Conditions: Near-dark for oxygenation imaging; ambient lighting for perfusion only.
  • Power Source: AC mains, 100-240 V, 50/60 Hz.
  • Dimensions: Scan head: 220x112x245 mm, 2.3 kg; PSU: 28x86x56 mm, 0.2 kg.
  • Laser Classification: Class 1.

System Features
The moorO2Flo-2 provides non-contact imaging, high spatial resolution, and the ability to capture blood flow and oxygenation videos. It supports multiple regions of interest for real-time and post-measurement analysis.

Software and Analysis
The system includes software for setup, measurement, and analysis, allowing flexible scan size and temporal resolution selection, event marking, and data export options.

Operating Principles
  • Perfusion Imaging: Uses laser speckle contrast analysis to create perfusion maps.
  • Oxygenation Imaging: Utilizes reflectance spectroscopy to generate maps of oxy- and deoxy-haemoglobin changes.

Warnings and Usage
The moorO2Flo-2 is for research and educational purposes only and is not a medical device. It may trigger seizures in individuals with photosensitive epilepsy.

Conclusion
Moor Instruments offers the moorO2Flo-2 as a cutting-edge tool for researchers and educators, providing comprehensive imaging capabilities for tissue perfusion and oxygenation.

About Moor Instruments
Moor Instruments, founded in 1987, specializes in micro-vascular assessments and has expanded to include tissue oxygenation assessments. They have extensive experience in laser Doppler research and prioritize quality and customer satisfaction.
See more

Catalog excerpts

MOORO2FLO-2-1

About Moor Instruments Simultaneous tissue perfusion and oxygenation imaging with moorO2Flo-2 Moor Instruments, established in 1987, is a world leader in the design, manufacture and distribution of monitoring and imaging systems for micro-vascular assessments. We are proud now to include tissue oxygenation assessments within this portfolio. Firsthand experience of laser Doppler research and development within Moor dates back to 1978 and with this we have the breadth of knowledge to help with your application and the enthusiasm to try and find answers to any of your questions. By giving priority to performance, quality and service, we strive to ensure the highest levels of customer satisfaction. Our dedicated design team is involved with a number of development projects for other partners and manufacturers. Whatever your needs, as a researcher, moorO2Flo-2 with LIGHTFRAME-SIZE1 or dark environment required for oxygen measurements. clinician or manufacturer, Moor will work harder for you. Specifications: Quality Control The moorO2Flo-2 is CE marked. Measured Parameters Tissue perfusion, in PU. Relative oxygenated and deoxygenated haemoglobin concentration change, in AU. Working Distance 100-380 mm (measured from front edge of enclosure). Imaging Area 8 x 6mm (maximum zoom, minimum distance) 300 x 200mm (minimum zoom, maximum distance) Image Resolution 2060 x 1540 for haemoglobin images. 2064 x 1544 for perfusion and colour photo/video images. Combined Imaging Frame Rate Up to 20 frames per second for oxygenation imaging or combined perfusion + oxygenation imaging. 1 Frame consists of: 1x perfusion image, 1x oxyHb change image, 1x deoxyHb change image and 1x colour video image. Up 100 frames per second for perfusion only imaging. Operating Environment Indoor laboratory use. Temperature range: 15 – 30°C. Atmospheric pressure: 86-106 kPa. Humidity: 20-80%, non-condensing. Maximum altitude: 2000 m. Pollution degree: Pollution degree 2 Storage And Transportation Environment Temperature range: 5 – 45°C. Atmospheric pressure: 50-106 kPa. Humidity: 20-80%, non-condensing. Power Source AC mains, 100-240 V +/-10%, 0.5A max, 50/60 Hz. Dimensions Scan head: 220x112x245 mm (WxHxD), 2.3 kg PSU: 28x86x56 mm (WxHxD), 0.2 kg Laser Classification Class 1 (EN 60825-1:2014+A11:2021). Measurement Laser Emission pattern: Diverging circular beam. Wavelength: 785nm ± 10nm Maximum power: 90mW, accessible power below EN60825-1:2014+A11:2021 Class 1 limits. Aiming Lasers Emission pattern: Collimated. Wavelength: 650nm Maximum power: 0.1mW per laser. The moorO2Flo-2 is intended for use in research and educational life science applications only and is not a medical device. WARNING: The moorO2Flo-2 emits flashing light which may potentially trigger seizures for people with photosensitive epilepsy. Do not use the moorO2Flo-2 in the presence of individuals with photosensitive epilepsy. Moor Instruments reserves the right to change specifications without notice. Lighting Conditions Oxygenation imaging: near-dark, controlled light environment or used inside a light proof enclosure Perfusion only imaging: normal, ambient room lighting innovation in microvascular assessment Moor Instruments Ltd Millwey Axminster Devon EX13 5HU UK tel +44 (0)1297 35715 fax +44 (0)1297 35716 email [email protected] Please visit www.moor.co.uk for full details of our international distributors and partners innovation in microvascular assess

 Open the catalog to page 1
MOORO2FLO-2-2

Simultaneous tissue perfusion and oxygenation imaging The moorO2Flo-2 is a unique imaging system designed to simultaneously image tissue perfusion and relative tissue oxyhaemoglobin and deoxyhaemoglobin changes. . The moorO2Flo-2 combines Moor Instruments’ existing high end laser speckle contrast technology for perfusion imaging with reflectance spectroscopy for oxygenation change imaging. The system offers; • Blood flow and oxygen videos of any exposed tissue (skin or surgically exposed tissues). Available in Blood flow only spec with up to 100 frames per second imaging. Combined Blood flow...

 Open the catalog to page 2
MOORO2FLO-2-3

Simultaneous tissue perfusion and oxygenation imaging The moorO2Flo-2 is a unique imaging system designed to simultaneously image tissue perfusion and relative tissue oxyhaemoglobin and deoxyhaemoglobin changes. . The moorO2Flo-2 combines Moor Instruments’ existing high end laser speckle contrast technology for perfusion imaging with reflectance spectroscopy for oxygenation change imaging. The system offers; • Blood flow and oxygen videos of any exposed tissue (skin or surgically exposed tissues). Available in Blood flow only spec with up to 100 frames per second imaging. Combined Blood flow...

 Open the catalog to page 3
MOORO2FLO-2-4

About Moor Instruments Simultaneous tissue perfusion and oxygenation imaging with moorO2Flo-2 Moor Instruments, established in 1987, is a world leader in the design, manufacture and distribution of monitoring and imaging systems for micro-vascular assessments. We are proud now to include tissue oxygenation assessments within this portfolio. Firsthand experience of laser Doppler research and development within Moor dates back to 1978 and with this we have the breadth of knowledge to help with your application and the enthusiasm to try and find answers to any of your questions. By giving priority...

 Open the catalog to page 4

All Moor Instruments catalogs and technical brochures

*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.