Catalog excerpts
About Moor Instruments Continuous tissue oxygenation and temperature monitoring with moorVMS-OXYTM Moor Instruments, established in 1987, is a world leader in the design, manufacture and distribution of monitoring and imaging systems for micro-vascular assessments. We are proud now to include tissue oxygenation assessments within this portfolio. Firsthand experience of laser Doppler research and development within Moor dates back to 1978 and with this we have the breadth of knowledge to help with your application and the enthusiasm to try and find answers to any of your questions. By giving priority to performance, quality and service, we strive to ensure the highest levels of customer satisfaction. Our dedicated design team is involved with a number of development projects for other partners and moorVMS-OXY™ – tissue oxygen saturation, haemoglobin and temperature monitor with optional moorVMS-LDF™ laser Doppler monitor. manufacturers. Whatever your needs, as a researcher, clinician or manufacturer, Moor will work harder for you. Quality Control Moor Instruments is certified to ISO 13485: 2003. The moorVMS-OXY™ is CE certified. Measurement Parameters SO2 (tissue oxygen saturation) Range: 0-99 % Accuracy: ± 2 SO2 units Resolution: 1 SO2 unit oxyHb* (relative oxygenated haemoglobin concentration) Range: 0-1000 AU Accuracy: ±10% Resolution: 0.1 AU deoxyHb* (relative deoxygenated haemoglobin concentration) Range: 0-1000 AU Accuracy: ± 10% Resolution: 0.1 AU totalHb (relative total haemoglobin concentration) Range: 0-1000 AU Accuracy: ± 10% Resolution: 0.1 AU Temperature (tissue temperature) Range: 5-50°C Accuracy: ± 0.3°C Resolution: 0.1 °C Reliability Assured by our 3 year basic warranty or 5 year extended warranty. Light Source White light, wavelength range: 400nm-700nm Maximum optical output power: 6mW. SO2 Signal Processing Wavelength range: 500-650nm Spectral resolution: 2nm Integration time: 1ms-20ms auto setting, 1ms-10sec manual setting* Outputs LCD screen providing display of oxygen saturation SO2, total haemoglobin and temperature (temperature enabled probes only). USB interface for connection to PC. Data rate (for all measurement parameters): 40Hz Analogue outputs: BNC sockets, 0-5V. 1 x SO2, 1 x oxyHb, 1 x deoxyHb, 1 x Temperature All outputs have independent user selectable scaling. General Power source: Universal voltage, 100-230V AC, 30VA, 50 to 60Hz. Dimensions: W x H x D mm, Weight: Kg moorVMS-OXY™: 235 x 80 x 200, 1.8kg. Operating environment: Clinic or laboratory, excluding domestic. Operating temperature: 15-30ºC. Classification Medical devices directive 93/42/EEC: Class IIa, Active device for diagnosis. LED classification: Class 2 per IEC 60825-1:2001. Type of protection against electric shock: Class I. Degree of protection against electric shock: Type BF applied parts. Protection against harmful ingress of water: IPX0 (not protected). Not suitable for use in an oxygen rich atmosphere. Not suitable for use in the presence of flammable anaesthetics. Safety Standards Complies with: IEC 60601-1:2005, IEC 60601-1-2:2007, IEC 60825-1:2001. ISO 10993-1:2003, Medical devices directive 93/42/EEC and amendment 2007/47/EC. FDA Laser Notice No. 50; dated June 24, 2007. Moor Instruments reserves the right to change specifications without notice. *Feature only available whilst using the PC Windows™ software, please contact us for a demo version. innovation in microvascular assessment Moor Instruments Ltd Millwey Axminster Devon EX13 5HU UK tel +44 (0)1297 35715 fax +44 (0)1297 35716 email sales@moor.co.uk website www.moor.co.uk innovation in microvascular assessment
Open the catalog to page 1moorVMS-OXYTM - Continuous Tissue Oxygenation Monitoring Adequate oxygen supply is essential for the life and health of all biological tissue. Both oxygen levels and tissue blood flow (measured by moorVMS-OXY™ and moorVMS-LDF™ respectively) are therefore important physiological indicators of tissue health and viability. The White Light Spectroscopic Technique This is to allow a rapid and accurate measurement of oxygenation saturation SO2(%), total haemoglobin and oxygenated / deoxygenated haemoglobin levels in the sample volume. Because the technique uses a non- The moorVMS-OXY™ uses the...
Open the catalog to page 2moorVMS-OXYTM - Continuous Tissue Oxygenation Monitoring Adequate oxygen supply is essential for the life and health of all biological tissue. Both oxygen levels and tissue blood flow (measured by moorVMS-OXY™ and moorVMS-LDF™ respectively) are therefore important physiological indicators of tissue health and viability. The White Light Spectroscopic Technique This is to allow a rapid and accurate measurement of oxygenation saturation SO2(%), total haemoglobin and oxygenated / deoxygenated haemoglobin levels in the sample volume. Because the technique uses a non- The moorVMS-OXY™ uses the...
Open the catalog to page 3About Moor Instruments Continuous tissue oxygenation and temperature monitoring with moorVMS-OXYTM Moor Instruments, established in 1987, is a world leader in the design, manufacture and distribution of monitoring and imaging systems for micro-vascular assessments. We are proud now to include tissue oxygenation assessments within this portfolio. Firsthand experience of laser Doppler research and development within Moor dates back to 1978 and with this we have the breadth of knowledge to help with your application and the enthusiasm to try and find answers to any of your questions. By giving...
Open the catalog to page 4All Moor Instruments catalogs and technical brochures
-
moorVMS-TREND
4 Pages
-
moorVMS-VASC
4 Pages
-
moorVMS-LDF_Brochure
4 Pages