one use plus
6Pages

{{requestButtons}}

Catalog excerpts

one use plus - 1

LASIK Surgery One Use-Plus The Moria Option for SBK

Open the catalog to page 1
one use plus - 2

One Use-Plus Accuracy and predictability equivalent to Femto-SBK One Use-Plus SBK Flap thickness using ultrasound pachymetry1 Flap thickness with Femto-SBK 60 kHz2 Richard Duffey, MD (Mobile, AL, USA) Guy Kerizian, MD (Paradise Valley, AZ, USA) Intended thickness 100 microns 100 microns Average 103 microns 109 microns Standard Deviation 9 microns 10 microns Minimum 83 microns N/A Maximum 123 microns 131 microns Surgeon Smoother stromal bed surface with One Use-Plus SBK than with Femto-SBK1 Scanning Electron Microscopy x1601 After cutting a flap with One Use-Plus SBK with an intended flap...

Open the catalog to page 2
one use plus - 3

Faster visual recovery Equivalent visual outcomes With One Use-Plus SBK than with Femto-SBK to Femto-SBK at 1 month One Use-Plus SBK - Dr. Duffey (Mobile, AL, USA)1 One Use-Plus SBK - Dr. Duffey1 Femto-SBK - Dr. Durrie (Overland Park, KS, USA)3 Femto-SBK - Dr. Durrie3 UCVA at 1 day postoperative UCVA at 1 month postoperative N=50 N=50 N=50 N=48 100 100 90 90 82 75 50 52 38 88 98 90 100 100 75 50 50 45 25 16 20/16 or better 0 % eyes 20/20 or better 20/25 or better 100 25 20/16 or better 20/20 or better 20/25 or better 20/40 or better 0 % eyes Equivalent quality of vision Better biomechanical...

Open the catalog to page 3
one use plus - 4

Greater patient comfort with One Use-Plus SBK than with Femto-SBK Pain score at 1 to 5 hours post surgery ‘‘ The pain occurred at a much lower frequency and intensity with One Use-Plus SBK in the first one to five hours after surgery than with IntraLase SBK.’’ Richard J. Duffey, MD Mobile, AL, USA One Use-Plus SBK - Dr. Duffey1 Femto-SBK - Dr. Duffey1 0,80 N=10 N=10 4,80 0 1 2 3 4 5 6 7 8 9 10 0 = no pain 10 = worst imaginable pain None of the reported complications of Femto-LASIK Intraoperative: • Potential laser eye tracking difficulties5 • Macular haemorrhage6,7 • Suction loss8 • Strong...

Open the catalog to page 4
one use plus - 5

The new • Thin flaps • Planar architecture One Use-Plus • Beveled edges • Customized diameters • Unrivaled bed smoothness • Accuracy and predictibility creates thin, planar, predictable flaps and stromal beds of unrivaled smoothness equivalent to Femto-SBK 108 96 104 108 110 112 104 Flap thickness profile with One Use-Plus SBK Courtesy of James S. Lewis, MD, Elkins Park, PA, USA Visual outcomes at 1 month postop equivalent to reported Femto-SBK results • with faster visual recovery • with greater patient comfort • and at a fraction of the cost. Flap thickness profile with Femto-SBK 60 kHz2...

Open the catalog to page 5
one use plus - 6

One Use-Plus • Linear and automated microkeratome • Pre-assembled and one-handed usage possible • Outstanding ergonomics • Safety and reliability of two independent motors: • one for head advancement • one for blade oscillation • Design of suction ring makes the use of a speculum unnecessary on small fissures • Translucent ring enables visual confirmation of suction • Adjustable stops for customized hinge length • Intra-operative visibility • Evolution3E operates Epi-KTM, the DSAEK system and all other Moria microkeratomes A Single-Use head means unrivalled simplicity, safety, convenience,...

Open the catalog to page 6