1. Catalogs
  2. MPW MED. INSTRUMENTS
  3. M-UNIVERSAL M-DIAGNOSTIC M-SCIENCE User Manuel

M-UNIVERSAL M-DIAGNOSTIC M-SCIENCE User Manuel

M-UNIVERSAL M-DIAGNOSTIC M-SCIENCE User Manuel
1 / 85 PagesView full catalog

M-UNIVERSAL M-DIAGNOSTIC M-SCIENCE User Manuel

Product catalog summary
Application
MPW M-DIAGNOSTIC, MPW M-SCIENCE, and MPW M-UNIVERSAL centrifuges are tabletop laboratory devices designed for in vitro diagnostic purposes. They are used to separate samples based on density differences using centrifugal force and are suitable for routine medical analyses and biochemical research. They require closed containers for biohazardous materials and are not suitable for caustic, inflammable, or explosive substances.
Technical Specifications
The centrifuges operate on various mains voltages (100V to 230V) with a frequency of 50Hz or 60Hz. The maximum connected load is 190W or 220W, with a current protection of T 8A. They have a capacity range of 100ml to 500ml, speeds from 90 to 18,000 rpm, and force up to 24,270 x g. They support short-time and continuous operation modes and can store up to 100 user programs. They comply with electromagnetic compatibility standards and are designed for indoor use within specific ambient conditions.
Installation
The centrifuge should be installed on a stable, flat surface, away from heat sources and direct sunlight, with a safety zone of at least 30cm for ventilation. The power supply must match the rating plate specifications, and emergency cut-outs are recommended for safety.
Operating Safety
Only trained personnel should operate the centrifuge, and the user manual must be accessible at all times. The guarantee period is 24 months, with a recommended technical inspection after this period and annually thereafter. Hazardous materials should be centrifuged in hermetically sealed tubes to prevent contamination.
Operating Instructions
The centrifuge features a microprocessor control system, a quiet motor, and safety features like electromagnetic locks. Proper installation and use of rotors and accessories are crucial for safe operation. The control panel allows for operation management, including starting and stopping centrifugation, and navigating through menus to set parameters like RPM, RCF, and time.
Maintenance
Regular maintenance includes cleaning with mild detergents, checking rotor clamping threads, and ensuring accessories are free from corrosion. Specific guidelines are provided for sterilization and handling of different materials. Reports can be generated post-centrifugation and transferred to a PC via USB.
Troubleshooting
Includes emergency lid release procedures and other troubleshooting tips. Error messages inform users of operational problems, such as power shortages or rotor incompatibility.
Guarantee, Transport, and Storage
Information on the guarantee, proper transport, and storage conditions is provided.
Disposal
Guidelines for the disposal of the centrifuge are included.
Manufacturer’s Info
Contact details for the manufacturer and distributor are provided.
Annexes
Includes additional accessories, declarations of conformity (CE, ROHS 2), and a nomogram for RPM/RCF.
Overview of Laboratory Tubes and Accessories
The document provides a detailed list of laboratory tubes and accessories, specifying their dimensions, capacities, and compatible brands. It includes various types of tubes such as glass tubes, tubes with caps, and conical bottom tubes from brands like Eppendorf, Thermo Nalgene, Sarstedt, and Greiner.
Procedures and Recommendations
Guidance on the use of specific tubes for different laboratory applications is provided, indicating compatibility with various centrifuge rotors. Some tubes are noted as not available from MPW, with equivalent alternatives suggested.
Rotor Parameters
The document specifies rotor parameters such as RPM and RCF for different tube types, along with details on the angle and maximum radius for rotor compatibility.
Optional Accessories
Optional accessories available for use with the tubes are listed, enhancing their functionality in laboratory settings.
See more

Catalog excerpts

M-UNIVERSAL M-DIAGNOSTIC M-SCIENCE User Manuel-1

USER MANUAL MPW M-UNIVERSAL Laboratory centrifuge MPW M-DIAGNOSTIC Laboratory centrifuge MPW M-SCIENCE Laboratory centrifuge Serial number of the centrifuge: ………………………………………………………. For centrifuges with serial no (SN): MPW M-UNIVERSAL: from 102MU013219 MPW M-DIAGNOSTIC: from 102M

 Open the catalog to page 1
M-UNIVERSAL M-DIAGNOSTIC M-SCIENCE User Manuel-2

This manual was prepared with special care. MPW MED. INSTRUMENTS may change the manual at any time and without notice because of improvements, typographical errors or improvements to facilities All rights reserved. No part of this User Manual may be modified, distributed, published or reproduced without the prior permission of MPW MED. INSTRUMENTS. You can find the current version of the user manual on our website under: www.mpw.pl DOWNLOAD section (one should choose demanded language version of website). Warning signs: WARNING! Warning of potential injury or health risk. DANGER! Risk of electric...

 Open the catalog to page 2
M-UNIVERSAL M-DIAGNOSTIC M-SCIENCE User Manuel-4

ADDITIONAL ACCESSORIES DECLARATION OF CONFORMITY ROHS 2 D. DECLARATION OF DECONTAMINATION (repair / return) E.

 Open the catalog to page 4
M-UNIVERSAL M-DIAGNOSTIC M-SCIENCE User Manuel-5

1 Application MPW M-DIAGNOSTIC/MPW M-SCIENCE/MPW M-UNIVERSAL centrifuges are table top laboratory centrifuges for in vitro diagnostic (IVD). Devices are used for separation samples taken from people's, animal’s and plant’s components of different densities, under the influence of the centrifugal force, to provide information about their biological state. Its construction ensures easy operation, safe work and wide range of applications at laboratories engaged in routine medical analyses, biochemical research works etc. This centrifuge is not bio tight and therefore during centrifugation of preparations...

 Open the catalog to page 5
M-UNIVERSAL M-DIAGNOSTIC M-SCIENCE User Manuel-6

3 Installation Open the package. Remove the box containing the accessories. Take out centrifuge from the container. Keep the box and packing materials in case of service shipping. Content of the package name centrifuge MPW M-UNIVERSAL/MPW M-DIAGNOSTIC / MPW M-SCIENCE / complete clamp spanner for the rotor spanner for emergency opening of the cover power cord 230V / 120V fuse WTA T8A 1150V vaseline 20ml USB A-A cable user manual The device is heavy, so lifting and carrying the centrifuge can lead to back injuries. Risk of injury while lifting and carrying heavy loads. Lifting and transporting...

 Open the catalog to page 6
M-UNIVERSAL M-DIAGNOSTIC M-SCIENCE User Manuel-7

Before switching on, check whether the centrifuge is connected to power supply correctly. It is obligatory to use only power cord reccomended by manufacturer (17866 for 230V, 17867 for 120V). Current protection The centrifuge is equipped with thermal current protection. Fuse is situated in the plugin socket unit at back wall of the centrifuge. 4 Operating safety Operating personnel ▪ ▪ ▪ ▪ ▪ Laboratory centrifuge can be operated by laboratory personnel after getting acquainted with user manual. This User Manual is part of the device. User manual shall be always held near the centrifuge. The centrifuge...

 Open the catalog to page 7
M-UNIVERSAL M-DIAGNOSTIC M-SCIENCE User Manuel-8

It is necessary to insert test tubes symmetrically on the opposite sides. Fill test tubes outside the centrifuge. Please pay special attention to the quality and proper thickness of the glass test tubes walls. Those shall be test tubes for centrifuges. Fill test tubes outside the centrifuge. Safety hints ROTORS MAINTENANCE ▪ ▪ ▪ Lubricate the swing-out rotor journal pins. Use only accessories in good condition. Protect equipment against corrosion using accurate preventive maintenance. Make sure that rubber O-rings are lightly coated with silicone grease. Use high vacuum grease, e.g. type „C”...

 Open the catalog to page 8
M-UNIVERSAL M-DIAGNOSTIC M-SCIENCE User Manuel-9

Maintenance conditions START-UP ▪ Prior to switching the centrifuge on, one shall read carefully all sections of this instruction in order to ensure smooth operation and avoid damages of this device or its accessories. In order to protect the centrifuge against unbalance, fill in the test tubes up to the same weight. Centrifuge must not be transported with the rotor mounted on the shaft.. One must use original rotors, test-tubes and spare parts only. In case of faulty operation of the centrifuge one shall ask for assistance of service of MPW MED. INSTRUMENTS company or its authorized representatives....

 Open the catalog to page 9
M-UNIVERSAL M-DIAGNOSTIC M-SCIENCE User Manuel-10

It is not allowed to use the rotors and round carriers with signs of corrosion or other mechanical defects. It is not allowed to centrifuge highly corrosive substances which may cause material impairment and lower mechanical properties of rotor and round carriers. It isn’t allowed to use rotors and accessories not admitted by the manufacturer. Let to use commercial glass and plastic test tubes, which are destined to centrifuging in this laboratory centrifuge. One should absolutely not use poor quality elements. Cracking of glass vessels and test tubes could result in dangerous vibration of the...

 Open the catalog to page 10
M-UNIVERSAL M-DIAGNOSTIC M-SCIENCE User Manuel-11

Rys.4. Back of the centrifuge I. Main socket II. Fuse socket III. USB [M-UNIVERSAL only] 1. Motor axle 2. Rotor 3. Rotor lid 4. Complete clamp Rys.3. Assembly of angle rotor The centrifuge has rigid self-supporting structure. Front and lid was made of ABS type plastic. Lid is fixed on steel axles of hinges and from the front it is locked with two electromagnetic locks blocking possible opening during centrifugation. Rotation chamber casing was made of thick steel sheet. The rotation chamber bowl is made of stainless steel sheet. Name plate Centrifuge model Catalogue number Power supply parameters...

 Open the catalog to page 11
M-UNIVERSAL M-DIAGNOSTIC M-SCIENCE User Manuel-12

Rotor and accessories installation ▪ ▪ ▪ Connect the centrifuge to the mains (master switch on the back side of the centrifuge). Turn on the centrifuge (button on the side of the centrifuge). Open the cover of the centrifuge by pressing the COVER key (see section Centrifuging/Control Panel). Prior to putting the rotor in, one has to check if the rotating chamber is free of impurities, e.g. such as dust, glass splinters, residues of fluids that must be taken away. One shall fit the rotor on the motor shaft driving it home on the cone. Screw-in the bolt for fixing the rotor (clockwise) and screw...

 Open the catalog to page 12

All MPW MED. INSTRUMENTS catalogs and technical brochures

  1. MPW-380/R

    4  Pages

  2. MPW-150R

    4  Pages

  3. MPW 260/R/RH

    4  Pages

  4. MPW-352/R/RH

    4  Pages

  5. MPW-351e

    4  Pages

  6. MPW-54/55/56

    4  Pages

  7. M-BASIC

    4  Pages

*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.