The Complete Platform for APSD Data Management Compliant Data. Confident Decisions. One Connected Platform.
Open the catalog to page 1The Complete Platform for APSD Data Management Generating accurate Aerodynamic Particle Size Distribution (APSD) data is a critical requirement in OINDP testing. However, this process is frequently challenged by fragmented workflows and manual data handling. Analysts often need to enter data across multiple systems, validate spreadsheets, and track down essential test parameters and metadata. These factors contribute to inefficiencies, compliance risks, and increased potential for errors. Connected Insights with Inhalytix®+ Inhalytix+ overcomes these challenges by unifying the entire APSD data...
Open the catalog to page 2Why Users Choose Inhalytix®+ All-in-One Platform for APSD Analysis Inhalytix+ integrates every stage of the APSD data management workflow into a single, connected system. Method preparation, equipment connectivity, data capture, and reporting are all managed within one environment to minimise manual steps and promote consistent operations. Instant Calculation of Key Metrics The platform automatically calculates critical values such as MMAD, GSD and FPD from test data, enabling timely review and decision-making. Improved Data Integrity By allowing automated data transfer from connected equipment,...
Open the catalog to page 3The Complete Platform for APSD Data Management Inhalytix®+ is specifically designed to support the compliance needs of regulated laboratories. It fully aligns with Good Manufacturing Practice (GMP) and 21 CFR Part 11 for electronic records. Every feature supports data integrity throughout the entire testing process - from method setup to final reporting. Secure, permission-based user management with defined roles, strong password policies and accountability tracking. System-wide validation verifies that all calculation algorithms work correctly, ensuring data reliability and regulatory compliance....
Open the catalog to page 4Structured Workflow for Consistency Inhalytix®+ leads users through a structured, three-step workflow that standardises data capture and strengthens traceability at every stage of APSD data analysis. 1. Prepare Define Method, Equipment, and Reports • Method Configuration Each test method is tailored to the specific product and its analytical requirements. Users can define APIs, stage groupings, Fine Particle Dose (FPD) thresholds, and reporting settings. Depending on the product type, either delivered dose or drug substance delivery rate can be selected. Inhalytix+ supports up to six APIs per...
Open the catalog to page 5The Complete Platform for APSD Data Management Once the method, equipment and reporting setup are defined, users can begin testing by entering the number of doses actuated and recording drug deposition values for each stage of the impactor. This includes any additional components configured in the test setup, such as induction ports or preseparators. This process is repeated for each run in the series. Data can be imported from CSV or XLSX files or entered manually. All entries are displayed in a clear, scrollable table, allowing users to review and edit values before proceeding with analysis....
Open the catalog to page 6Inhalytix®+ creates a digital inventory that consolidates all equipment records in one place. Each item can be linked to key details such as: • Model and serial number • Firmware version • Calibration and maintenance history • Usage and operational data This metadata is automatically connected to the related test method and results, enhancing traceability and making audits more straightforward. Inhalytix+ supports two flexible ways to integrate equipment data: • Online Devices: Newer Copley ancillary and automation tools can connect directly to Inhalytix+, enabling automatic import of metadata...
Open the catalog to page 7The Complete Platform for APSD Data Management Built for Today, Ready for Tomorrow. Inhalytix®+ is designed not only to support today’s connected testing environments, but also to lead future developments in inhaler testing integration. Compatibility with connected equipment is a core design principle, and future tools will continue to be developed with seamless Inhalytix+ integration in mind. This ensures that labs adopting Inhalytix+ today are positioned for long-term success as testing environments modernise. Technical Specifications Installation & Deployment Options Inhalytix®+ offers flexible...
Open the catalog to page 8Inhalytix ®+ is provided as a subscription that includes: V Unlimited test run analyses V Continuous compliance and feature updates V Built-in audit trails V Customisable methods and reporting V Full technical support V Optional user training packages V Licences available for teams of three users or more Frequently Asked Questions How long does it take to install and set up Inhalytix+? Typical installation takes less than a day, depending on your IT environment. Pre-configured method templates and the Equipment Bench feature help speed up method setup and analysis. What support is available after...
Open the catalog to page 9The Complete Platform for APSD Data Management Frequently Asked Questions Can Inhalytix+ be integrated into a larger LIMS or digital lab workflow? While Inhalytix+ is designed to work as a standalone data analysis platform, exported reports can be used downstream in broader digital lab systems. Do I need internet access to use Inhalytix+? No. Inhalytix+ runs on local PCs or servers within your lab’s secure environment. An internet connection is only required for initial licensing activation and for software update downloads. How are user roles and permissions managed? User access is role-based,...
Open the catalog to page 108265P Inhalytix+ Software Licence (3 users, valid for 3yrs) - PC 8265S Inhalytix+ Software Licence (3 users, valid for 3yrs) - Server 8266 Additional User Licence for Inhalytix+ (valid for 3 yrs) (each) 8021 1 Port RS-232 to Ethernet Adapter for Inhalytix+ 8022 2 Port RS-232 to Ethernet Adapter for Inhalytix+ 8024 4 Port RS-232 to Ethernet Adapter for Inhalytix+ 8021, 8022 or 8024 are required to connect ancillary and automation equipment to Inhalytix+. Direct connection is only supported for devices with compatible firmware. To check compatibility with existing equipment, please contact Export...
Open the catalog to page 115 Pages